Used Tensile Test for sale (11,252)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing

1,034 km
Climate test chamber with humidity, 800 liters
EspecPSL-4KPH -70°C bis +150°C
Call
Condition: excellent (used), Espec
Type: PSL-4KPH
Espec Temperature and Climate Test Chamber, Air-Cooled
There is a small dent at the top edge of the door (see photo).
Ibsdpfx Aewz Er Ueacjc
The door closes perfectly, the seal is intact, and the climate chamber operates without any technical faults.
The dent is purely cosmetic and does not affect function, sealing, or control accuracy in any way.
Temperature range: -70°C to +150°C
Humidity range: 20 to 98% relative humidity
Temperature/Humidity fluctuations: ±0.3°C / ±2.5% r.H.
Temperature/Humidity stability: ±0.5°C / ±3% r.H.
Heating/Cooling rates and times:
- Heating time: within 30 min from +20 → +100 °C
- Cooling time: within 115 min from +20 → –40 °C
- Heating rate: 3.0 °C/min
- Cooling rate: 1.0 °C/min
Test chamber dimensions: Width 1000 mm x Height 1000 mm x Depth 800 mm
External dimensions: Width 1410 mm x Height 1983 mm x Depth 1593 mm
Port with silicone plug: 100 mm
equipped with RS232 interface
Test chamber volume: 800 liters
Refrigerants: R-404A, R-508A
Stainless steel construction, AC 400 V 3φ, 50Hz 31 A
Net weight approx. 720 kg
For your safety as a buyer, the following measures are performed in advance on our offered chambers:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Upon successful inspection, the chambers undergo a test run monitored with calibrated devices.
Condition: used
Scope of delivery: (see photo)
(Subject to change and error in technical data and specifications!)
We are happy to answer further questions by phone.
Listing

585 km
Filter Integrity Test Unit
PallPalltronic Compact 200
Call
Condition: ready for operation (used), Condition Used
Stock Number 413002
This listing is for a Pall Palltronic Compact 200 Filter Integrity Test Unit.
The unit is in full working condition and is ready for immediate release.
Ibjdpfx Asvl Aw Djacec
Listing

1,034 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Type: VT 7012 S2
Water-cooled
Two-chamber design
Hot chamber:
Ibsdpfx Aaowzilrecjc
The temperature range of the hot chamber is from +50°C to +220°C.
Temperature deviation over time in the center of the chamber is ± 1 K.
Temperature deviation over space is ± 2 K.
Temperature change rate:
Heating: 11 K/min.
Cold chamber:
The temperature range of the cold chamber is from -80°C to +70°C.
Temperature deviation over time in the center of the chamber is ± 1 K.
Temperature deviation over space is ± 2 K.
Temperature change rate:
Heating: 2 K/min.
Cooling: 3 K/min.
Test chamber volume: 125 liters.
Hot chamber temperature range: +50°C to +220°C.
Cold chamber temperature range: -80°C to +70°C.
Test chamber dimensions: Width: 470 mm. Depth 650mm Height 410mm
External dimensions: Width 930mm Depth 2115mm Height 1970+mm
Plug-in diameter 67mm
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power 10 kW
Rated current 25 A
Refrigerant R404A / R23
Weight: 1000 kg
For your safety, the following information is provided as a buyer!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing

585 km
Filter Integrity Test Unit
PALLPalltronic Compact Star
Call
Condition: ready for operation (used), Condition Used
Stock Number 413003
This listing is for a PALL Palltronic Compact Star.
Isdpfx Aevl Awwjacobc
The unit is in full working condition and is ready for immediate release.
Supplied with 2 replacement Epsom Ribbon Cartridges and software disk.
An automated integrity test, whether forward flow or pressure hold, is internationally acknowledged as a truly objective and non-destructive method for determining if a filter meets microbial removal specifications and is correctly installed. Test results providea clear and accurate indication of a filter’s integrity prior to its use.
Integrity testing with the Palltronic Compact Star device is reliable,cost-effective, and operator-friendly. The unit is designed to per-form a Pressure Hold Test, a nondestructive method that measures pressure decay over a period of time. The test involves automatically pressurizing the filter housing at a predetermined level, allowing the pressure to stabilize. The unit then takes the test measurement and depressurizes the assembly through the vent valve. Fully automated, the Palltronic Compact Star device eliminates the variability of test results that can occur with manual systems. It provides a simple, fast, and objective check of filter integrity
Listing

1,034 km
Temperature test chamber 990 liters
VötschVT³ 4100 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4100
Ibedpfxowyu H Eo Aacjc
Water-Cooled Temperature Test Chamber
S!MCON/32.NET (with Touch Panel)
Control System Features:
- Color touchscreen with intuitive menu navigation (typically 5.7" or larger)
- Programming of temperature/humidity profiles with ramps and dwell times
- Data acquisition & logging (e.g., temperature profile, alarms)
- USB port for data export (CSV, optionally S!MPATI compatible)
- Network interface (Ethernet) for remote monitoring and control
- User management with password protection
- Interfaces: Volt-free contacts, optionally Modbus or Profibus
VT³ 4100 – Technical Specifications (Temperature Test Chamber)
- Test volume: 990 liters
- Temperature range: -40 °C to +180 °C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1.5 K
- Temperature gradient: 1 to 3 K
- Temperature change rate (per IEC 60068-3-5):
• Heating: 4.0 K/min
• Cooling: 3.0 K/min
- Maximum heat compensation capacity: 4500 W
- Calibration values: +23 °C and +80 °C
- Internal dimensions (W×D×H): 1100 × 950 × 950 mm
- External dimensions (W×D×H): 1390 × 1955 × 1995 mm
Feed-Throughs:
The chamber is equipped with feed-throughs on both the right and left sides, allowing insertion of measuring cables and test devices into the test space.
• 1 × L1 nominal width 50 mm
• 1 × R1 nominal width 125 mm
• 3 × R1 nominal width 50 mm
Electrical connection: 3/N/PE AC, 400V ±10%, 50Hz
Power consumption: 11.5 kW
Rated current: 22 A
Noise level: approx. 62 dB(A)
Refrigerant: R452A
Weight: 920 kg
Important information for buyers:
For your security, the following measures are carried out on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data; information may be subject to alteration!)
For any further questions, feel free to contact us by phone.
Discover more used machines
Listing

1,034 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-10 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-10
Vötsch Climate Test Chamber, Water-cooled
Specifications for Temperature Testing:
- Temperature range: -70°C to +180°C
- Temporal temperature deviation at the center of the usable test volume: ±0.3 to ±0.8 K
- Spatial temperature deviation: ±0.5 to ±2 K
- Temperature gradient: 1 to 4 K
- Temperature change rate:
- Heating: 11 K/min
- Cooling: 10.5 K/min
Specifications for Climatic Testing:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98% RH
- Temporal temperature deviation at the center of the usable test volume: ±0.2 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1 K
- Temperature gradient: 1 to 2 K
- Temporal humidity fluctuation at the center of the usable test volume: ±1 to ±3 % RH
Technical Data:
- External dimensions (with hinges and door lock):
- Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
- External dimensions (without hinges and door lock):
- Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
- Internal chamber dimensions:
- Height: 950 mm, Width: 1100 mm, Depth: 950 mm
- Test chamber volume: approx. 1300 liters
Feedthroughs:
- The chamber is equipped with feedthroughs on both the right and left sides, allowing measurement cables and test devices to be routed into the test space.
- 1 x R1 NW 125 mm
- 1 x L1 NW 50 mm
Test Chamber Lighting:
- Halogen bulb 24 V, 50 W
Electrical specifications:
- 3/N/PE AC 400V ±10% 50Hz
- Rated power: 34.0 kW
- Rated current: 50.0 A
- Fuse (to be provided on site): 100 A slow-blow
- Max. heat emission to environment: 2.2 kW
Permissible Test Specimen Weight:
- Total load on grate supports: 100 kg
- Chamber floor: 150 kg; Inserted rack: 50 kg
Refrigerants:
- R 404A / R 23
Weight: 1600 kg
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
Ibedpfx Aaowynmxocjc
2. If required, recharge with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in technical data and information!)
For further questions, please feel free to contact us by phone.
Listing

1,034 km
Temperature test chamber -70°C to +180°C
VötschVT 7021
Call
Condition: excellent (used), Heraeus Vötsch
Type: VT 7021
Air-cooled temperature test chamber
1 port, nominal width 80 mm,
Test chamber volume: 210 liters
Isdpfowylv Dox Aacjbc
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (heating): 2.5 K/min
Temperature change rate (cooling): 2.5 K/min
Max. heat compensation: 800 W
Test chamber dimensions: Width 560 mm, Depth 570 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1250 mm, Height 1640 mm
Electrical connection: 1/NPE AC 230 V ± 10% 50 Hz
Rated power approx. 1.8 kW, rated current 12 A
Refrigerant: R404A and R23
Weight: 355 kg
For your safety as a buyer, please note the following information!
The following procedures are performed on the chambers we offer, in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Subject to technical modifications and errors in the details!)
For further questions, please feel free to contact us by phone.
Listing

1,034 km
Temperature test chamber 600 liters
VötschVT 7060 –40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VT 7060
Vötsch VT 7060 Temperature Chamber 600 Liter with Simcon 32-net
Chamber is air-cooled
Reliable climate chamber for demanding environmental simulations
Ideal for laboratory, development, and quality assurance applications.
Device Description:
For sale is a professional temperature chamber from the manufacturer Vötsch Industrietechnik, model VT 7060 with SIMcon 32-net controller.
This powerful unit is suitable for a wide range of demanding environmental simulations—from material testing and electronics tests to long-term climatic stress tests.
Technical Data (Excerpt):
Model: Vötsch VT 7060
Internal volume: approx. 600 liters
Temperature range: –40°C to +180°C
Temperature deviation in steady-state conditions:
Temporal: ±0.1 K to ±0.5 K
Spatial: ±0.5 K to ±2.0 K
Temperature change rates (without test specimen):
Heating: 4 K/min
Cooling: 3 K/min
Control system: SIMcon 32-net with touchscreen panel
Interfaces: RS232, optional RS485/422
1 × port NW 50 mm left
Ibedjwybb Nopfx Aacoc
1 × port NW 125 mm left
2 × ports, each NW 125 mm right
External dimensions (approx.): Width 1090 × Height 1960 × Depth 1995 mm
Internal dimensions (approx.): Width 800 × Height 800 × Depth 950 mm
Rated voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 9.1 kW Rated current: 19.0 A
Refrigerants: R 404A and R 23
Weight: approx. 675 kg
For your safety as a buyer, please note the following information!
The following points are carried out on the chambers we offer before sale:
1. Functional check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, the chambers undergo a documented trial run.
Shipping / Collection:
Collection preferred
Shipping on pallet via freight forwarder Europe-wide possible.
(Shipping costs depending on effort)
Condition: used
Scope of delivery: (See picture)
(Specifications and possible errors subject to change!)
For further questions, please feel free to contact us by phone.
Listing

1,034 km
Climate test chamber 600 liters with humidity
CTSC-70/600 -70°C bis +180°C
Call
Condition: excellent (used), CTS
Type: C-70/600
Climate Test Chamber CTS C-70/600
incl. Programming/Evaluation Software CID-PRO
– Year of manufacture: 2020 – Water-cooled – Fully equipped – Excellent condition
For sale is a high-quality climate test chamber CTS C-70/600 from 2020, with the latest housing design, water cooling, and extensive special equipment.
The unit is ideally suited for precise climate and temperature testing in research, development, and quality assurance.
Full Equipment includes:
- Volt-free contact for fault reporting
- 2 digital outputs, volt-free – for controlling test samples externally
- Software temperature limiter (min. and max. freely adjustable)
- Ethernet interface
- Programming and evaluation software CID-PRO included
- Observation window in the door
- Automatic water replenishment
- Independent temperature limiter (PT100)
- 1x pipe port NW 50 (right side)
- 2x pipe ports NW 125 (right side)
- 2x pipe ports NW 125 (left side)
- Compressed air connection, switchable via digital channel
– for dry compressed air to prevent condensation
- Mobile/caster-mounted device design
Temperature Testing:
- Temperature range: -70 °C to +180 °C
- Temperature deviation: 0.1 K to 0.3 K over time (in stabilized condition)
- Mean temperature change rate, without test item and without radiant heat:
Heating: 3.5 K/min
Cooling: 3.0 K/min
(in the range from +180 to -65°C)
- Radiant heat max. 4000 W at +20°C
Climate Testing:
- Temperature range: +10°C to +90°C
- Humidity range: 10% to 98% rel. humidity
- Dew point range: +7°C to +94°C
- Temperature deviation: 0.3 K over time
- Humidity deviation:
1 – 2% r.h. over time up to 90% r.h.
max. 1 – 3% r.h. over time above 90% r.h.
Test chamber dimensions:
Height: approx. 850 mm, Width: approx. 850 mm, Depth: approx. 830 mm
External dimensions:
Height: approx. 1900 mm, Width: approx. 1115 mm, Depth: approx. 1850 mm
Isdpswxxf Ajfx Aacebc
Test chamber volume: 600 liters
Electrical connection: 400V 3/N 50Hz
Power rating: 8.7 kW, Nominal current: 14.6 A
Refrigerants: R452A / R23
Weight: 700 kg
Important information for your security as a buyer!
The following steps are performed on all chambers we offer prior to sale:
1. Function check and replacement of necessary components
2. Refilling with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of supply: (See image)
(Specifications and information subject to change and error!)
We are happy to answer any further questions you may have by phone.
Listing

1,034 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
Ijdpfswxc I Ujx Aacobc
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
For further questions, please feel free to contact us by phone.
Listing

1,034 km
Stress test chamber
EspecEHS-221M
Call
Condition: excellent (used), Espec
Here we offer an Espec(ThermoTec) stress test chamber.
Overpressure humidity tests at over 100 degrees in many different modes
Program capacity of 10 patterns with 30
steps per pattern
A variety of protection mechanisms; overheat/overpressure protection, detection of water-
supply failure.Complete door interlock and temperature sensor.
Saturated Temp Range 105 to 142.9°C
Unsaturated Temp Range 105 to 132.9°C
Humidity range 50 to 100% r.h.
Ibjdpfx Aajn Arznscjc
Nominal pressure 0.196 MPa at 132.9°C and 100% e.F.
External dimensions: width 740 x height 1553 x depth 1000 mm
Test chamber dimensions: Width 355x Height 355 x Depth 426 mm
Other equipment:
with rails and grid
Test material connections in the interior
Type: EHS-221M
Scope of delivery: See pictures
300 kg
Condition: Used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

1,034 km
Temperature test chamber
RS-SimulatorenTS 600/45 EX
Call
Condition: excellent (used), RS Simulators
Here we offer a test cabinet.
Water cooled
Temperature range: -40°C to +180°C
Test chamber dimensions: 850mm x 850mm x 800mm (WxHxD)
Outer dimensions: 1100mm x 1850mm x 1500mm (WxHxD)
current consumption: 13,5 A
Refrigerant: R404A
Connection voltage: 3x400V/N/PE 9A
Ibodpfx Aasg Urq Ijcec
Weight: approx. 750kg
Type: TS 600/45
Explosion proof operation not tested
but Max 160°C in this
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer gladly on the phone for you.
Listing

1,034 km
Temperature test chamber 350 liters
CTSTS-70/350 -70°C bis 180°C
Call
Condition: excellent (used), Here we offer you a temperature test cabinet.
Water cooled
Technical performance data:
Temperature working range
Temperature range in °C -70 / +180°C
Rate of change according to DIN 50 011, part 12
Cooling rate: approx. 5 K/min
Heating rate: approx. 5 K/min
Dimensions:
Test volume: 350 liters
Test chamber dimensions height, approx. 750 mm, width, approx. 650 mm, depth, approx. 720 mm
External dimensions height, approx. 1800 mm, width, approx. 850 mm, depth, approx. 1640 mm
Operating data:
Electrical connection 400 V, 3/N, 50 Hz.
nominal power 13,3 kW
Refrigerant: R404A / R23
Weight: approx. 650 Kg
Type: TS-70/350
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Ibjdpfx Aen Sl T Ssacsc
Further questions we can answer on the phone for you.
Listing

1,034 km
Stress test chamber
EspecEHS-221MD
Call
Condition: excellent (used), Espec
Here we offer an Espec (ThermoTec) stress test chamber.
Outer dimensions: W x H x D: 860 x 1795 x 1000 mm
Test chamber dimensions W x H x D: 355 x 355 x 426 mm
2 x 46 l
Voltage 230 V 1/N 50 Hz
Ibedpfopdm Uyjx Aacec
Rated current 37A
Fuses 250 V , 2 x 3 A
Type: EHS-221MD
Temperature range: + 105°C to + 142.9°C
Humidity range 75 to 100 % r.H.
Temperature constancy: -+ 0.5 °C
Pressure range: 0 to 2.0 kg/cm²
Heat-up or pressure build-up time: from 0 to 2.0 kg/cm² in about 60 minutes
390 kg
Condition: Used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

1,034 km
Temperature test chamber
Heraeus VötschHT 7010 -70°C bis +180°C
Call
Condition: excellent (used), Type: HT 7010
Heraeus Vötsch temperature test cabinet, water-cooled
Temperature deviation in time ± 1 K
Temperature deviation in space ± 2 K
Housing dimensions: Width 820 mm Depth 840 mm Height 1670 mm
Interior: Width 550 mm Depth 350 mm Height 550 mm
Rated voltage: 230V +6/-10% 1/N 50Hz
Rated power: 3.2 kW Rated current: 14.5 A
Temperature range -70°C to + 180°C
2 x side feedthrough 9cm
Weight approx. 260 kg
Refrigerant: R404A and R23
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
Ibsdpfxjhhyz Ss Aacjc
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

1,034 km
Vibration test system
RMSSW 3509 + TGD 6000-000.00
Call
Condition: excellent (used), RMS Vibration Test System
Here we offer you a RMS electrodynamic vibration test equipment.
Technical data:
Sine:7,5 KN
Noise:6,7 KN
Shock:13 KN
Displacement pk-pk:26 mm
Speed:
Sine 1,5 m/s
noise 2,5 m/s
Shock 2,5 m/s
Ibjdehylymspfx Aacsc
Acceleration:100g
Cooling:air cooled
Type : SW 3509 + amplifier TGD 6000-000.00 and fan
total weight ca 4000kg
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Written order possible by email or fax
Listing

1,034 km
Climatic test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Ibodpfx Aouudx Dsacjc
Listing

1,034 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have over the phone.
Ibodeu H U Twopfx Aacjc
Listing

1,034 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss temperature shock test chamber air cooled
( Compressor was renewed ! )
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot-/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Ijdpfek E Htyjx Aacobc
Width ( without and with swivel arm ) without....ca. 1820 mm with....ca. 1915 mm
Depth ( without and with test chamber door ) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

1,034 km
Temperature shock test chamber
CTSTSS-70/130 +50°C...+250°C -80°C...+100°C
Call
Condition: excellent (used), CTS
Type: TSS-70/130
CTS water-cooled temperature shock test chamber
Type series TSS -70/130
Test chamber volume 130 liters
Test chamber dimensions:
Height, approx. 410 mm Width, approx. 480 mm Depth, approx. 660 mm
External dimensions:
Isdpetql H Aefx Aacjbc
Height, approx. 1820 mm Width, approx. 940 mm Depth, approx. 2335 mm
Temperature operating range:
Temperature range in °C :
Hot chamber +50/+250°C
Cold chamber -80/+100°C
Retempering of ICs < 15 min in kg 10.0
Car changeover time in sec. < 10
Max. test weight in kg 50
Temperature constancy over time in K ± 1
Electrical connection 400 V +6% -10%, 3/N, 50 Hz
Connected load in kW approx. 16.6
Condenser chiller water-cooled
Test chamber weight in kg approx. 950
Sound pressure level in dB(A) < 60
Feed-through Ø in mm 125
Refrigerant: R404A/R23
Weight: 950 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,034 km
Temperature test chamber 600 liters
CTST-40/600 -40...180°C
Call
Condition: excellent (used), CTS
Type: T-40/600 /011232
CTS Temperature Test Chamber, Water-Cooled
Includes metal struts to increase the floor load-bearing capacity
Test chamber volume: 600 liters
Ibsdpfx Aaswfdniecec
Test chamber dimensions:
Height approx. 850 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions:
Height approx. 1900 mm, width approx. 1050 mm, depth approx. 1850 mm
Temperature operating range:
Temperature range -40 to +180°C
Temperature deviation ±0.1 to ±0.3 K over time
Heating rate: 2.5 K/min
Cooling rate: 3 K/min
Electrical connection: 400 V +6% -10%, 3/N, 50 Hz
Rated power: approx. 5.5 kW
Rated current: approx. 8.5 A
Refrigerant: R-404A
Weight: 550 kg
For your safety, please note the following information!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Trust Seal
Dealers certified through Machineseeker

Listing

1,034 km
Temperature test chamber 335 liters
VötschVT 4034 -40°C..+180°C
Call
Condition: excellent (used), Vötsch
Type: VT 4034
Vötsch Temperature Cabinet VT 4034 Air-Cooled
Refrigerant: Converted to R-452 A
Internal dimensions: Height 750 mm, Depth 765 mm, Width 580 mm
External dimensions: Height 1780 mm, Depth 1595 mm, Width 865 mm
Temperature range: -40°C to +180°C
Temperature deviation:
temporal ± 0.1 to ± 0.5 K
spatial ± 0.5 to ± 2.0 K
Heating 3.2 K/min
Cooling 3.5 K/min
Maximum load (evenly distributed across the surface)
of the test chamber floor: 60 kg
per insert: 30 kg
Total load of the grate supports: 80 kg
Test chamber lighting: 24 V halogen bulb 50W
Rated voltage: 3/N/PE AC 400V ± 10% 50 Hz
Rated power: 4.1 kW
Ibedewd Hpajpfx Aacjc
Rated current: 12.5 A
Fuse provided by the customer: 16 A slow-blow
Refrigerant: R-452A
Weight: 490 kg / 335 liters
For your safety, the following information!
The following steps are carried out on our chambers in advance:
1. Functional test and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

1,034 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Designation: SB2/500/80 water cooled
Cold-heat operation: -75°C ...+180°C
Climatic operation: +10...+95°C
Humidity range: 10...98 % r. h.
Temperature constancy, temporally ± 0.2K
Humidity constancy: ±1 r.F.
Temperature rate of change:
Cooling: approx. 1.4 K/min
Heating up: approx. 2.5 K/min
External dimensions: Height 1980 mm, width 1265 mm, depth 1365 mm
Feedthroughs:
left side: ∅ 100 mm
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/ 50 Hz
Power: 10,4 kVA
Weight: approx. 720 kg
Refrigerant R404a / R 23
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: SB2/500/80
Condition: used / used
Ijdpfx Aaem Tvzcecjbc
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

1,034 km
Temperature test chamber
FeutronTPK 200 Typ: 3416/17
Call
Condition: excellent (used), Feutron temperature test chamber
Here we offer a temperature test chamber.
Feutron temperature test chamber air-cooled
Nominal test chamber volume: 280 liters
dimensions
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door dismantled: 1500 x 1940 x 925 mm
Test chamber: 720 x 690 x 560 mm
Door, clear width: 720 x 690 mm
Viewing window, heated: 500 x 600 mm
Temperature range
-70°C to +180°C
Heating: 4.0 K /min
Cooling: 0.6 K /min
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Max. power requirement: 6.3 kW
Iedpfxsk Scxmo Aacjbc
Weight: 600 kg
Type: 3416/17
Refrigerant: R507 / R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,034 km
Climate test cell with humidity
Feutron3707/06 Temp. -40°C bis 150°C
Call
Condition: excellent (used), Here we offer a Feutron climate test cell.
Feutron climate test cell
Temperature
Temperature range: -40...90°C
Climatic range (without heat load) 10...85°C
Temperature difference,temporal during temperature operation ≤ ± 0.5 K/min.
Temperature difference,temporal at climatic operation ± 1,0... ± 1.5 K/min
Rate of change
Heating 2.0 on average K/min
Cooling 2,0 in average K/min
The IEC 1646 standard can be realized with testing, solar modules with max. 160kg weight and non-linear ramps.
(setpoint step change) can be realized
Drying
Air drying Condensation drying
Humidity
Humidification of air Steam humidification
Humidity range 10... 95 % r.h.
Iodpfx Aasklv H Iocsbc
Humidity difference,temporal ≤ ± 3,0... ±5.0 %r.H.
Dew point range 8... 80,9 °C
Test room
Test room volume 7.0m³
Dimensions
Test room dimensions width 1500 mm x height 2250 mm x depth 2000 mm
Revolving door DIN right heated,i,l.. width 900 mm x height 2100 mm
Viewing window, heated with darkening flap and lockable Width 500 mm x height 600 mm
Feed-through opening 2x in front side right ∅ 75 mm
Irradiation unit test room
Cut-out 4x in side panel left for SC 2500 850 x 700 mm each
Area to be irradiated when using SC 2500 1200 x 1200 mm
Intensity of radiation at 1.0 m distance from wall 1000 ± 10% W/m²
Lighting 1xhalogen lamp 200W
Refrigeration system Bitzer compressor semi-hermetic 2-stage,air-cooled
Condenser: split condenser (outdoor installation winter control)
Refrigerant R507 /R23
Temperature control system
Cooling brine medium Tyfocor / water
Mixing ratio 50/50
Density of cooling brine 1,072 kg/dm³
Filling quantity approx. 80dm³
Pyranometer Temperature range -40... 150°C
Max. Radiation absorption 4000 W/m²
Spectral range (50% points) 305... 2800nm
Sensitivity (norminal) 7 µV/W/m²
Power supply Test cell
Electrical mains connection 400V, 3/N/PE, AC, 50Hz
Connection type fixed connection
Max. simultaneous power requirement approx. 32.0 kW
Supply line fuse 3 x 63, Char C (A)
Power supply SolarConstant
Electrical mains connection 400V, 3/N/PE, AC, 50Hz
Connection type
Max. simultaneous power requirement approx. 30.0 kW
Supply line fuse 3 x 63, Char C (A)
Outer dimensions of the test cell complete with: Genset room/switch cabinet
and control cabinet for SolarConstant 2500
Outer dimensions of aggregate room width 3440 mm x height 2580 mm x depth 2950 mm
/switch cabinet width 2200 mm x height 1830 mm x depth 1100 mm
Outer dimensions of condenser, split width 900 mm x height 950 mm x depth 2000 mm
Mass of test cell, total approx. 2700 kg
Mass of condenser, empty 153 kg
Weight : 2700 Kg
Type: 3707/06
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
We make it easier for you to find: "tensile test"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Tensile Test (11,252)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month