Used Climatic Chamber for sale (5,990)
Sort results
- Lowest price Highest price
- Latest listings Oldest listings
- Shortest distance Farthest distance
- Latest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Latest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Latest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation A to Z
- Designation
- designation Z to A
- Designation
- Model A to Z
- Model
- Model Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest running time
- Runtime
- Relevance
- Relevance
Listing

1,034 km
Climatic test chamber 190 liters with humidity
VötschVC³ 4018 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 4018
Klolovpt Inohccqpjt
Vötsch Climatic Test Chamber VC³ 4018 Air-Cooled
Converted to R452a
Technical Specifications:
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Plug-in included in standard equipment
R1: ® 125 mm
L1: © 50 mm
Data for temperature tests:
Temperature range: -40°C to +180°C
Temperature deviation over time ± 0.1 to ± 0.5 K
Temperature homogeneity over space ± 0.5 to ± 1.5 K
Temperature rate of change
Heating 4 K/min
Cooling 4 K/min
Max. heat compensation 2300 W
Data for climatic tests:
Temperature range +10 to +95 °C
Dew point range -3 to +94 °C
Humidity range 10 to 98 %RH
Temperature deviation over time ±0.1 to ±0.3 K
Temperature homogeneity over space ±0.5 to ±K
Humidity deviation over time ±1 to ±3 %RH
Heat compensation 400 W
Data for operation:
Test room lighting: halogen bulb 2 x 24V, 50W
3/N/PE AC 400V±10% 50 Hz
Rated power 4.1 kW
Rated current 14 A
Weight: 470 kg
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

917 km
Climatic chamber
BinderKBF 240
Call
Year of construction: 2010, Condition: used, Manufacturer: Binder
Model: KBF 240
Year : 2010
Klolhcjv I D Ebjcqpet
Type : Constant climate chamber
Maximum temperature: 70°C
Humidity control using a humidity sensor and steam humidification
Power: 2.10 kW
Volume: 240 litres
Maximum pressure: 15 bar
Inside dimensions: D 45 x W 65 x H 75 cm
Exterior dimensions: D 80 x W 93 x H 146 cm
VWR inspection: 04/2023
Listing

1,027 km
Walk-in climatic test chamber
Vötsch VSKZ 04/120/S
Call
Year of construction: 1996, Condition: excellent (used), Vötsch VSKZ 04/120/S walk-in climatic test chamber
Manufacturer: Vötsch
Type: VSKZ 04/120/S
Temp. range: -40°C to +120°C
Mains voltage: 400V
Rated current: 95A
Rated output: 56 kW
Refrigerant VK: R 404 A
Year of construction: 1996
External dimensions: W 2850 x D 4100 x H 3080 mm
SO-01
Further articles - new and used - can be found in our store!
International shipping costs on request!
Kelsuuigyjhccqpelt
Listing

1,032 km
Vötsch climatic test chamber Fitotron HGC1014
Vötsch Klimaprüfschrank 5°C bis +45°Fitotron HGC 1014 V Schrank 3 mit Bel.
Call
Condition: excellent (used), Functionality: fully functional, Year of construction: 2012, Fitotron® Modular Plant Growth Chambers, Type HGC 1014 V, including HQI-T and Krypton Lighting Module
Temperature range +5°C - +45°C for temperature testing
Test chamber volume approx. 1300 l
Simpac Control System
Network Connection
USB Connection
The Fitotron® HGC series plant growth chambers are based on a modular design. Individual modules can be added or replaced as needed. This allows them to be adapted to different applications. They are suitable for plants with high light requirements, such as wheat, corn, cotton, rice, and C4 plants.
Lighting HQI-BT-400 W/D and 100 W,
Temperature range +5°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% RH approx. 0.8 kW
Characteristics for climatic tests with irradiation
Kjlhsvz U Ersccqpslt
Temperature range +10°C to +45°C with light on +10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Humidification and dehumidification system, stainless steel test chamber
Internal dimensions: Height 1400 mm, Depth 750 mm, Width 1270 mm
External dimensions: Height 1985 mm, Depth 980 mm, Width 2320 mm
External dimensions with lighting module: Height 2450 mm
Single door with observation window
Interface for computer connection
Connection 3/N/PE 400V ±10% 50Hz
CE marking, mobile, very good condition
Pipe penetration ∅ 50 mm
Air cooling
Refrigerant R404A
Weight approx. 480 kg + 130 kg lighting module
Listing

1,867 km
Binder MKF 400 E5 – climatic chamber -40°C to +180°C, 400L, excellent condition
BinderMKF 400 E5
Call
Condition: like new (used), Binder MKF 400 (2025) – Climatic chamber, perfect condition, exhibition machine
Klolhccewb U Hnjqpot
Model: Binder MKF 400
Year of production: 2025
Condition: like new – device after factory tests, used only as a demonstration copy (demo)
Capacity: 400 liters
Availability: immediately
Documentation: complete, with declaration of conformity
Warranty: yes (start-up)
VAT invoice: yes
Location: Grabina 92-701, Poland
Description:
We offer a professional Binder MKF 400 climatic chamber, ready to work, in perfect technical and visual condition. The device comes from 2025, was used only for exhibition purposes, so it has no traces of use.
The MKF 400 model is a premium solution for customers in the pharmaceutical, electronics, automotive and research industries, offering precise control of climate conditions in accordance with ICH, IEC and ASTM standards.
⸻
Key parameters:
• Capacity: 400 liters
• Temperature range: from -40°C to +180°C
• Humidity range: from 10 to 98% RH
• e™ technology - guarantee of uniform temperature and humidity distribution
• Color touch screen, intuitive menu
• Built-in data logger, USB / Ethernet interface
• Possibility of programming complex test profiles
• Solid construction, quiet operation, energy efficiency
⸻
Why is it worth it?
• Perfect condition - new machine, not used in production
• No waiting time - immediate availability
• Attractive price compared to the catalog price
• Possibility of on-site testing or online presentation
• Technical support, optional transport
Listing

1,027 km
Climatic test chamber -40°C to +120°C Chamber
Vötsch VSKZ 04/120/S
Call
Condition: excellent (used), Vötsch VSKZ 04/120/S
Climatic test chamber
-40°C to +120°C
Kjlhccqeu Hghmjpjlt
climatic chamber
Climatic chamber
Inside: Width 2.60 m Depth 2 meters Height 2 meters
Listing

1,034 km
Climatic chamber 8m³ with humidity #1
EspecEWSH282-4CW -65°C bis 150°C
Call
Condition: excellent (used), Espec
Type: EWSH282-4CW
Temperature and Climatic Test Chamber
Water-cooled
Temperature range: -65°C to 150°C
Temperature fluctuation: ±1°C
Temperature gradient: ±2°C
Temperature change rate
Heating: approx. 2.5K/min
Cooling: approx. 2.5K/min
Humidity range: 20 to 95°C RH
Humidity fluctuation: ±5% RH
Humidity gradient: ±5% RH
Klslhjkl Axteccqpst
Dimensions
External dimensions: Width 2324 mm, Depth 4006 mm, Height 2889 mm
Internal dimensions: Width 1829 mm, Depth 1829 mm, Height 2388 mm
Voltage: 8.0 m³
Weight: approx. 3,600 kg
Power supply: 400V, 3PH, 50HZ (+5% / 10%)
Controller: Espec SCP-220
Refrigerants: R-404a and R-508b
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

1,829 km
Climatic test chamber
VötschVCL 4010
Call
Year of construction: 2007, Condition: good (used), Functionality: fully functional, Good working condition
Klelhcsv Rg Aujcqpjt
Listing

1,867 km
Memmert HCP 105 climatic chamber
MemmertHCP 105
Call
Year of construction: 2018, Condition: like new (used), Memmert HCP 105 climatic chamber as new.
Manufacturer's description:
Memmert HCP series climatic chambers are designed for long-term tests at controlled temperature and humidity, including stability tests and conditioning of material samples before other tests.
Perfect simulation of the environment in a humidity chamber
The chamber offers a full range of comfort, reliability and safety. It has active humidity control in the range of 20% to 95% relative humidity and unparalleled temperature and humidity uniformity throughout the interior. The chamber is suitable for environmental tests, environmental simulations, accelerated life tests and 85/85 tests according to IEC 60068-2-67 and IEC 60068-2-78.
Temperature range up to +90°C available,
4 model sizes (capacity from 56 to 241 litres),
1 model variant: TwinDISPLAY,
Active humidity control 20 to 95% RH,
Double doors as standard:
1. Prevention of contamination,
2. Prevention of temperature drops or increases,
3. Optimum view of the sensitive chamber load thanks to the heated internal glass door with a large surface area.
Humid environment without condensation,
Kelhccqewhxx Ijpelt
Active humidity control ensures ideal temperature and humidity uniformity and short temperature recovery times after opening the door.
Virtually maintenance-free climate chamber.
In combination with heating on all six sides, including the heated internal glass door, evaporation in the interior is minimised, and thus the risk of condensed water dripping onto the test item. The aluminium heat-conducting layer supports optimum temperature distribution and serves as a heat accumulator in the event of a temporary power failure.
Convenient equipment for accelerated life tests
To ensure that environmental tests and accelerated life tests such as 85/85 tests run reliably and safely, the HCP humidity cabinet offers a wide range of comfort features:
Standard feedthrough in the rear wall,
Battery-buffered ControlCOCKPIT (option),
The process run time starts with the SetpointWAIT function only after the set temperature has been reached,
Alarm messages can be sent via e-mail or SMS using MobileALERT (option) and many more.
The Memmert humidity chamber offers unique advantages
Intuitive and easy-to-use menu,
Heating concept specially adapted to precise and uniform temperature control,
A wide range of programming options and documentation of different temperature/humidity profiles using the AtmoCONTROL software,
Alarm functions, triple overheating protection and simultaneous display of all parameters ensure the safety of samples and cell cultures
Almost exclusive use of high-quality and easy-to-clean stainless steel for the working chamber and housing,
3-year worldwide warranty.
Working temperature and humidity range HCP,
Listing

1,034 km
Climatic chamber
Heraeus VötschVC³ 0100
Call
Condition: excellent (used), Heraeus Vötsch climatic test chamber
Here we offer Heraeus Vötsch climatic test chamber.
Designation VC³ 0100
Test chamber dimensions: H x W x D, approx. 950 x 1100 x 950 mm
TEMPERATURE TESTS:
Minimum temperature -0°C
Maximum temperature +90°C
Temperature change rate cooling 0.2 K/min
Temperature change rate heating 0.5 K/min
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.0 K
Heat compensation at +20 °C 350W
CLIMATIC TESTS:
Minimum temperature +10°C
Maximum temperature +90°C
Dew point temperature range +4°C to +89.5°C
Humidity range 10 to 98% r. h.
Humidity deviation over time ± 1 to ± 3% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3K
Temperature homogeneity in space ± 0.5 to ± 1.0K
Voltage: 1/N/PE AC 230V±10% 50Hz
Rated power: 2.6 kW
Nominal current: 12 A
Refrigerant: R 404A
Weight approx. 1400 kg
Kslhccqjn Ard Sopelt
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Type: VC³ 0100 / year of construction 2013
Condition: second-hand / used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,867 km
Memmert HPP 260 climatic chamber
MemmertHPP 260
Call
Condition: excellent (used), Memmert HPP 260 climate chamber for sale
Operating temperature range from 0°C (20°C below ambient temperature) to +70°C Capacity 260 liters. Humidity adjustable from 10 to 90%RH.
Temperature
Setting temperature range
without light, with humidity: +5 to +70 °C
Setting temperature range
with light, with humidity: +5 to +70 °C
Setting temperature range
with light, without humidity: 0 to +70 °C
Setting temperature range
without light, without humidity: 0 to +70 °C
Working temperature range
with light, without or with humidity: 15 to +40 °C
Working temperature range
without light, with humidity: +5 (at least 20 below ambient temperature) to +70 °C
Working temperature range
without light, without humidity: 0 (at least 20 below ambient temperature) to +70 °C
Humidity
Setting range humidity
Kslhccqovtxp Ejpslt
10 - 90% rh
Control technology
Function HeatBALANCE
adapting the distribution of the heating performance of the upper and lower heating circuit from -50 % to +50 %
Standard equipment
Works calibration certificate
standard values +10 °C and +37 °C, 60 % rh at +30 °C
Door
fully insulated stainless steel door with 2-point locking (compression door lock)
Door
inner glass door
Listing

1,034 km
Climatic chamber
CTSCS-70/1850-5
Call
Condition: good (used), CTS climatic test chamber
Here we offer a CTS climatic test chamber.
Climate test chamber type: CS-70/1850-5 water-cooled
1) C means: Climate
2) S means: stress screening
3) -70 means: lower temperature -70°C
4) 1850 means: 1850 liter test chamber volume
5) 5 means: Temperature change rate of 5 K/min according to IEC 60068-3-5
Test chamber lighting:
Halogen lamp 20 W, 12 V
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoint values
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Technical performance data:
Temperature tests:
Temperature range -70°C to +180°C
Temperature deviation ≤ ± 0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 5 K/min
Cooling 5 K/min
Heat radiation:
approx. 5500 W at +20°C
approx. 5500 W at ± 0°C
approx. 3700 W at -40°C
Climatic tests:
Temperature range +10°C to +95°C
Humidity range 10% to 98% rel. humidity
Dew point range I: +7°C to 94°C
Dew point range II (deep dehumidification): -10°C to +7°C
Temperature deviation ≤ ± 0.3 K in time
Humidity deviation I ≤ ±1.5% r.h. over time
Humidity deviation II ≤ ±3 % r.h. over time
Dimensions:
Test volume 1850 liters
Test chamber dimensions: Height 1085 mm Width 1470 mm Depth 1400 mm
External dimensions: Height 2210 mm Width 1600 mm Depth 2645 mm
Insert grid:
Stainless steel, support surface 1300 x 1170 mm
Max. load per shelf 35 kg
Total load with max. grate load 100 kg
1a Pipe feed-through NW 50
1b Pipe feed-through 2x NW 125
2 Control panel
3 Window 570x710
4 Electrical connection, fixed
5 Pressure equalization
7 Test chamber drain and
air conditioning system R 1/2 "i
8 Demineralized water inlet R 1/2 "i
9 Cooling water return R 3/4 "i
10 Cooling water inlet R 3/4 "i
11 Main switch
12 Electrical compartment
13 Compressed air R 1/4 "AG, option
14 Cable bushing for interface connections
Technical version:
Kslhjqzgwueccqpolt
Refrigeration unit:
Water-cooled, low-noise, semi-hermetic,
infinitely variable capacity adjustment through electronic
monitoring and control system, environmentally
friendly refrigerant R404A/ R23
Compressor: 4EC-4.2Y / 4CC-6.2Y
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Rated output: 33 kW Rated current: 41.3 A
Protection class: IP 22
Weight: approx. 1300 kg
Type: CS-70/1850-5
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,034 km
Climatic test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Kolhcceuudx Deqpolt
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,034 km
Climatic chamber
Espec EGNX12-6CWL
Call
Condition: good (used), Espec
Type: EGNX12-6CWL
Espec temperature and climate test chamber air-cooled
Temperature (and humidity) test chamber N series
Power supply:
AC 400/460 V 3-phase 50/60Hz 32A
Temperature range -70 to +180°C
Humidity range 10 to 95% r. H.
Temperature change rate
Heating 15 °K/min
Cooling 11 °K/min
Internal dimensions W x H x D in mm 600 x 750 x 850
External dimensions W x H x D in mm 889 x 2098 x 1768
Useful volume 380 l
Refrigerant R404A
Weight: 370 kg
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
Kslhcjt Nf Upocqpelt
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,034 km
Climatic chamber
VötschVCS 7033
Call
Condition: excellent (used), Heraeus Vötsch climatic chamber
Here we offer you a Heraeus Vötsch climatic chamber.
Vötsch climatic chamber VCS 7033 water cooled
Temperature range: -70°C to +180°C
Temperature change rate:
Heating 7.5 K/min.
Cooling 6,5 K/min.
Humidity range: 10% to 98% r.H.
Temperature deviation temporal ± 0.5 K
Temperature deviation time-related ± 1.5 K
Test chamber dimensions: Width 675 mm x Depth 650 mm x Height 760 mm
Housing dimensions: Width 930 mm x depth 1565 mm x height 1840 mm
Lateral feedthrough 90mm ∅
approx. 330 L Weight: 600 kg
voltage: 3/N/PE AC 400V ±6/-10% 50Hz
rated power 9,5 kW
Rated current 17 A
Klelspz H Hxehccqpot
Refrigerant R404A / R23
Type: VCS 7033
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

1,034 km
Climatic chamber
VötschVC³ 4100
Call
Condition: excellent (used), Vötsch climatic test chamber
Here we offer a Vötsch climatic test chamber.
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Unit dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Temperature change rate:
Heating 4.0 K/min
Cooling 3.0 K/min
Max. heat compensation at +20°C 4500 watts
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Temperature homogeneity in space ± 0.5 to ± 1.0 K
Humidity deviation temporal ± 1 to ± 3% r. h.
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Nominal current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
Klolhccoqmn A Noqpst
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,034 km
Temperature and climatic chamber
Heraeus VötschVC 350 LAF/S
Call
Condition: excellent (used), Here we offer a Heraeus Vötsch temperature and climate test chamber.
Heraeus Vötsch temperature and climate test chamber with Simcon/32-NET controller
and Hyfra cooling water recooler table-top unit VWK/1
TECHNICAL DATA :
General specifications:
Test chamber capacity: approx. 345 l
Weight: 375 kg
Data for mechanical stress:
maximum total load of the test chamber floor 60 kg
of which weighing stone 45 kg
Kelhccsdyaiioqpslt
Scales + test material approx. 15 kg
Storage shelves 3 kg
Permissible load per shelf approx. 100 g
Data for operation:
RS 232 interface
The RS 232 interface is used, for example, for external control via computer.
Lighting Operating instructions Safety cabinet
Interference emission; interference immunity Standards met see Declaration of Conformity
Nominal voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 5 kW
Rated current 9 A
Customer-side fuse 16A slow-blow
Noise measurement:
Sound pressure level measured at a distance of 1 m from the front,
1m height and free-field measurement approx. 58 dB(A)
Data for temperature tests:
Temperature +20 to +30 °C
Temperature fluctuation over time in the middle of the usable space ± 1 K
Heat compensation 100 W
Data for climate tests:
Data for humidification system
Water tank capacity approx. 10 l
Water quality demineralized
pH value 6 - 7
Conductivity max. 10 μs/cm
Temperature +20 to +30 °C
Humidity 30 to 70 % r.h.
Dew point +9.5 °C / +21 °C
Temperature fluctuation over time
in the middle of the usable space
(in steady state, according to IEC 60068-3-5)
± 3 K
Type: VC 350 LAF/S
Hyfra cooling water recooler table-top unit VWK/1
Plug-in units in air-cooled design.
Cooling capacities from 0.8 to 3.5 kW
Technical data for small appliances in table-top design VWK 7/1-S
Cooling capacity 814W
Air flow rate 500 m 3/h
Pump type LNY 2841
Compressor output 0.27 kW
Connected load 0.58 kW
Maximum current consumption 6.2 A
Maximum back-up fuse 10 A
Current type 1/N/PE ~ 50 Hz 230 V
Control voltage 230 V / 50 Hz
Tank capacity 6 liters
Water connection Plug-in couplings 6 and 9 mm
Fully hermetic design
Cooling type air-cooled
Length 565 mm , width 440 mm , height 335 mm
Type: VWK 7/1-S
Scope of delivery. (See pictures)
(We reserve the right to make changes and errors in the technical data).
We will be happy to answer any further questions you may have on the phone.
Listing

1,034 km
Climatic chamber
RS-Simulatoren
Call
Condition: excellent (used), RS Simulators
Here we offer a climatic test chamber.
Water cooled
Kljlhcjiivgvecqpjt
300 liters
Temperature range from -75 °C to +180 °C
Time deviation +- 0.2 K to +- 0.8 K
Average heating rate: approx. 2.1 K/min
Average cooling rate: approx. 1.2 K/min
Humidity range from 10 % to 98 % rel. humidity
Working climate range
Temperature: 10 °C to 95 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 1000 mm 1800 Height mm 1400 Depth mm
Voltage: 3x400V/N/PE Current: 40A
Refrigerant: R404a / R23
Type: KS 300 / 75
Weight: 630 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See pictures)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

1,034 km
Climatic test chamber
Feutron 3702/06
Call
Condition: excellent (used), Feutron
Type: 3702/06
Water-cooled climatic test chamber
Technical data:
Test chamber nominal volume 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width 2970 mm Height 2370 mm Depth 1530 mm
Rear wall
Klelhccek E Hnqsqpst
Minimum insertion dimensions: Width 2970 mm Height 2390 mm Depth 1550 mm
Test chamber: Width 2000 mm Height 1000 mm Depth 1000 mm
Double-leaf door, clear width Width 2000 mm Height 1000 mm
Heated viewing window, 2 pieces Width 500 mm Height 600 mm
Feed-through opening, 1 side panel left ∅ 75 mm
Temperature range: -40...100°C
Climatic range: 10...95°C
Temperature difference, temporal ≤ ± 0.5...± 1.0 ΔN/K
Change rates measured in the supply air without load
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Humidity range: 10...95 %r. F.
Humidity difference, temporal ≤ ± 3.0 %r. F.
Dew point range, temporary down to -5... 95°C
Refrigeration system: water-cooled semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Air conditioning and dryer refrigeration system air-cooled /hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical mains connection: 400V 3/N/PE.AC,50Hz
Mains plug: CEE 5-роlig, 32 A, with 5.0 m cable
Max. simultaneous power requirement 10.0 kW
Supply line fuse: 3x 25, Char, C A
Degree of protection IP20
Weight: 1300 kg
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications)
We will be happy to answer any further questions you may have on the phone.
Listing

1,034 km
Climatic chamber
Vötsch VCS 7034-5
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation in time K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Kslhccqjuxq T Dopjlt
We will be happy to answer any further questions you may have on the phone.
Listing

1,034 km
Climatic test chamber -40 to +180°C
WeissWK-480/40/10 480 Liter m. Feuchte
Call
Condition: excellent (used), Here we offer a Weiss climatic test chamber.
Water-cooled
Test chamber lighting Halogen bulb 24V, 50W
Data for temperature tests:
Temperature range: -40°C to +180°C
Temporal temperature deviation in the center of the chamber: ± 0.3 to ± 0.8 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate
Heating: 10 K/min
Cooling: 12.5 K/min
Heat compensation at +20°C 8000 W
Heat compensation at -20°C 3000 W
Klslhccqeq Dpzyepot
Data for climate tests
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % r.h.
Temperature deviation in time in the center of the usable space: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % RH
Test chamber dimensions: Height 950 mm, width 760 mm, depth 650 mm,
External dimensions: Height 2025 mm, width 1090 mm, depth 2480 mm,
Nominal voltage: 3/N/PE AC 400 V ± 10% 50 Hz
Rated current: 24 A Rated power: 16.0 KW
Refrigerant: R452A
Weight: approx. 900 kg
Type: WK-480/40/10
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing

1,034 km
Climatic chamber
Vötsch VC³ 4100
Call
Condition: excellent (used), Vötsch climatic test chamber
Here we offer a Vötsch climate test chamber.
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Device dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation in time ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Rate of temperature change:
Heating 4.0 K/min
Cooling 3.0 K/min
Kslhccqjqnutmopjlt
max. heat compensation at +20°C 4500 Watt
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Spatial temperature homogeneity ± 0.5 to ± 1.0 K
Humidity deviation temporal ± 1 to ± 3% r. h.
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after a successful check, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,728 km
66m3 (40 + 26 m3)
Two-chamber stainless steel tank
Call
Condition: excellent (used), Two-chamber stainless steel tank 66m3 (40 + 26 m3)
DIMENSIONS: - Diameter: 3,245 mm - Height: 13,053 mm
Year of manufacture 2006
Kljlovlpctohccqpot
Weight: 4,680 kg
Upper part: 40° slope - Lower part: 2% slope.
DN 600 hatch with hinged cover at the top.
stainless steel pressure-vacuum valve
At the bottom, a DN400 hatch with a hinged cover
a stainless steel pressure-vacuum valve
Upper tank heating: 6 coils, exchange surface 6.95 m2, PS 2 bar
Above 2 coils, exchange surface 2.33 m2, PS 2 bar
A device for moving grounds, test valve
Lower tank heating: 4 coils, exchange surface 4.64 m2, PS 2 bar.
Above: 2 coils, exchange surface 2.33 m2, PS 2 bar.
Liquid level gauge
555x432 rectangular hatch
DN70 ball valve
The tanks were used in the wine industry.
The tanks have a technical drawing.
The tanks are dismantled and ready for delivery.
Listing

6,052 km
Temperature & Humidity Chamber C7-270/10
Vötsch Climate test ChamberVötsch-C7-270/10
Year of construction: 2016, Condition: as good as new (ex-display), Functionality: fully functional, machine/vehicle number: 54260010110010, Vötsch Climatic Test Chamber C7-270/10 ESS | High-Precision Environmental Testing
🌍 Precision | 🔬 Reliability | ⚡ Performance
The Vötsch C7-270/10 ESS is a high-performance climatic test chamber designed for accurate environmental simulations across multiple industries. It ensures precise temperature and humidity control for reliability testing, thermal cycling, and environmental stress screening (ESS).
🚀 Key Features:
Kslhccqjvcywcepjlt
✅ 🌡️ Wide Temperature & Humidity Range – Perfect for extreme condition testing.
✅ 💨 Advanced Refrigeration System – Uses dual refrigerants (R404A & R23) for efficient cooling.
✅ ⚡ High Power Output – 20.2 kW performance with 36A current load.
✅ 🔌 Voltage & Pressure Ratings:
Voltage: 3/N/PE AC 380V +10%, 50Hz
Low Pressure: Max 18 bar g
High Pressure: Max 25 bar g
Constant Pressure: 17 bar g
🏭 Applications Across Industries:
🔹 📡 Electronics & Semiconductors – Thermal cycling, ESS, and product reliability testing.
🔹 🚗 Automotive – Extreme climate simulations for vehicle safety & performance.
🔹 ✈️ Aerospace – High-altitude, low-pressure environmental testing.
🔹 🌞 Renewable Energy – Durability testing for solar panels, wind turbines, and batteries.
🔹 💊 Pharmaceuticals – Stability testing under controlled humidity and temperature.
🔹 📦 Packaging & Materials – Evaluating product behavior under different conditions.
💡 Why Choose Vötsch C7-270/10 ESS?
🔥 Precision Control – Ensures tight regulation of temperature & humidity.
💰 Energy Efficient – Optimized for high performance with low energy consumption.
🔧 Durable & Reliable – Built with robust components for consistent long-term operation.
❄️ Advanced Cooling Technology – Uses efficient dual-refrigerant cooling for fast response.
Listing

1,034 km
Stress test chamber
Espec (ThermoTec)TPC-212D
Call
Condition: excellent (used), Espec
Type: TPC-212D
Technical Specifications
Test Procedure: HAST – Highly Accelerated Stress Test
Model: Espec TPC-212D
Internal Volume: 2x (approx. 22 liters)
Internal Dimensions (ø x L mm): 2x 295 x 330 mm
Kslhjwl D Aaeccqpolt
Temperature Range: +105 °C to +142.9 °C
Humidity Range: 75% to 100% RH
Pressure Range: 0.02 to 0.196 MPa gauge (0 to 28 psig)
Power Supply: 220 V (±5%), 1-Phase, 50/60 Hz, 20 A
Special Features: Two chambers in one device
Notes:
Two chambers: Allow for simultaneous tests with different parameters or larger test volumes.
HAST test: Accelerated endurance test under high temperature and humidity
with overpressure for the qualification of electronic components.
Applications: Ideal for semiconductors, ICs, circuit boards, MEMS, etc.
Weight: 230 kg
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions over the phone.
We make it easier for you to find: "climatic chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Climatic Chamber (5,990)
Search Machineseeker now with more than 200,000 used machines:This may be of interest to you