Used Climate Chamber for sale (5,835)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing

989 km
Climatic chamber - cleanroom
PK-Kältetechnik - Clean or Climate roomsClimate - Clean room
Call
Condition: like new (used), functionality: fully functional, Year of construction: 2018, PK clima – Clean Rooms
We can offer three different cleanroom configurations. Please let us know your required size:
A x 150 m² (3 chambers)
B x 320 m² (7 chambers) – 112 m² + 55 m² + 34 m² + 38 m² + 40 m² + 25 m²
C x (please specify)
Item 1) Cleanroom Block 1 approx. 150 m²
Inlet with the following technical specifications:
- Cleanroom Class ISO6
- Lighting: 300 lux
- All doors equipped with electric locks
Hnsdpfx Ajw Dddzeaceu
Manufacturer and model: MGB
- Clear room height: 2,500 mm throughout
On-site extraction system: 500–2,000 m³/h
Inlet slot: 1,800 x 50 mm
Outlet 1: 3,700 x 50 mm
Outlet slot: 1,800 x 50 mm
2 double doors
1 maintenance door
• DIG Cell: Solvent extraction via industrial exhaust fan
Manufacturer: Ghrd, with external drive motor and frequency converter
Approx. 5 g/m² solvent applied to the panel
Exhaust duct outlets 2 m above the cell
Roof penetrations and sealing to be provided by the customer
Negative pressure monitoring included
2 double doors
• T Cell: Extraction via industrial exhaust fan
Manufacturer: Ghrd, with external drive motor and frequency converter
Exhaust air combined with that of the DIG cell
Negative pressure monitoring to prevent solvent leakage to exterior
2 double doors
Comprising:
- Approx. 175 m² tongue-and-groove panel walls, RAL 9002, smooth finish, with eccentric fasteners
- Multiple window elements integrated into the panel walls as per specification
6 doors with windows (double-leaf, clear opening 1,800 x 2,000 mm)
1 operating room door (single-leaf, clear opening 2,000 x 2,200 mm)
6 electric door locks as described
22 filter fan units (1,140 x 1,140 mm each), with F7 pre-filter, H14 main filter, EC speed-controllable motor
Air volume: 2,350 m³/h
Nominal power: 350 W
Sound power: approx. 55 dB(A)
Approx. 40 lighting units with cover (no LED)
Approx. 200 m² cleanroom ceiling, make: O – metal ceiling
1 set of suspension structure for the metal ceiling, including maintenance grid for service and filter replacement from above
1 exhaust fan with ductwork
1 switch cabinet section for control
Additional option:
Item 3) Additional Air Conditioning for DIG Room
To achieve the specified room temperature and humidity, an additional air conditioning unit is required:
- Target room temperature: +20°C ±2K
- Target humidity: 60% ±10%
- Control integrated into main control cabinet
Listing

1,034 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Hnodpfxexmhycj Aacsu
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing

1,244 km
Heating oven, climate chamber, hot air oven, convection oven, heating cabinet
KÖTTERMANN2306
Call
Condition: used, Heating Oven Climate Chamber KÖTTERMANN Type 2306
Serial No. 783018 Year of manufacture: approx. 1980
Internal dimensions (W x H x D): 500 x 530 x 620 mm
Connected load: 4 kW
Power supply: 380 Volt, 50 Hz, 18.2 Amp.
- Recirculation fan
- Analog temperature controller for heating
- Analog temperature controller for cooling
- Integrated refrigeration unit
- Interior lined with stainless steel
Hnjdjxf Uxpopfx Aacsu
No functionality test performed
Control system outdated
Net weight approx. 250 kg

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing

1,065 km
Climate test chamber with humidity
WeissWKL 34/40
Call
Year of construction: 2011, operating hours: 3,210 h, condition: excellent (used), Climate test chamber, climate chamber, temperature test chamber WKL 34/40 by Weiss Umwelttechnik
Test chamber volume approx. 34 liters
Internal dimensions approx. 340 x 310 x 280 mm
1 shelf
Test chamber lighting: halogen
Power: 1.8 kW, 230 volts
0.8 kg refrigerant R404A
Temperature range: -40 to +180°C
Humidity range: 10 to 98% rH
Water tank for 13 liters of demineralized water
Simpati control system, color touch display
Test programs in automatic mode or manual for temperature and humidity only
CE mark
Hedpow U U Nhsfx Aacsnu
Very well-maintained heating chamber from prototype production in the motorsport department of a Wolfsburg-based automobile manufacturer.
Only 3,210 operating hours.
Unfortunately, no key available.
Dimensions approx. 580 x 950 x 980 mm (L x W x H). Weight approx. 190 kg.
The machine can be demonstrated on site by appointment. We only offer machines that are ready for demonstration in our warehouse; see 'More offers from this seller.'
Listing

1,027 km
Climate test chamber with seat pulsator
WeissSD 1400/+20 DU
Call
Condition: good (used), Weiss Climatic Test Chamber with Seat Pulsator
Manufacturer: Weiss
Type: SD 1400/+20 DU
Test Chamber:
Material: Stainless steel
Hedpjxbgrgofx Aaconu
Dimensions
Height approx. 800 mm
Width approx. 2000 mm
Depth approx. 900 mm
Capacity: 1440 liters
Outer casing
Material: Double-coated Zincor sheet
Dimensions
Height approx. 2000 mm
Width approx. 2200 mm
Depth approx. 2000 mm
HxWxD 2000 x 2200 x 2000 mm
Paint finish: Light gray (RAL 9002)
Double-leaf door: hinged on the left and right
Equipment:
Tubing in the floor and ceiling: 2 each, NW 100 mm, for installing the pulsator tables
Tubing in the the side walls: 1 each, left and right, 100 mm
Cooling unit: Air-cooled
Control: Digital measurement and control system DMR
Basic control panel: Integrated into the main switch panel
Interface: RS 232 C, for connection to a PC
Software: Operating software for MS Windows
Performance data:
Temperature range without air conditioning: +20...+100 °C
Temperature stability without air conditioning: +0.2 ... t0.5 K (over time) depending on the range, in steady state
Temperature range with air conditioning: 20...+95 °C
Temperature stability with air conditioning: +0.2 ... +0.5 K (over time) depending on the range, in steady state
Dew point range: 20...+94 °C
Humidity range: 10...98 % RH
Humidity stability: +3 ... +5 % RH depending on the range, in steady state
Temperature change rate measured in the exhaust without a test specimen and without load
- Cooling: 0.5 K/min on average, between +100 and +20 °C
⁃ Heating: 0.5 K/min. On average, between +20 and +100 °C
The performance specifications refer to an ambient temperature of max. +25 °C and the specified nominal voltage.
For proper operation of the system, the ambient temperature must be between +10 and +35 °C.
Seat test device with steel construction for placing and attaching to the climatic test chamber, including:
• 2 pneumatic weight lifting devices (150 mm stroke) for changing test specimens, 12 weights of 5 kg each
• 1 base frame in mild steel welded construction for attaching to the underside of the climatic test chamber. This frame is equipped with removable panels on all sides and has two hinged doors for adjusting the eccentricity. These doors have safety switches.
• 2 eccentric discs with bearings and tachometer, 2 connecting rods, 2 ball bearings,
• 2 mounting tables, perforated, 20 mm grid, 650 x 650 mm, for attaching the test specimens, made of aluminum, thickness min. 10 mm
• 2 mounting plates, perforated, 20 mm grid, 200 x 200 mm, for attaching the buttocks simulation
• 2 stainless steel 60° load rods (The connection to the test specimen is not included in our price, but can be offered subsequently upon precise specification.)
• 2 three-phase motors, 2 belt drives with tensioning devices,
• 1 pneumatic control unit with 2 manual valves, a filter-regulator unit, and a shut-off valve. 1 electrical control cabinet with 2 SEW frequency converters, hand switches, emergency stop button, 2 on/off switches, 2 speed indicators, 2 potentiometers for speed adjustment, 2 pre-selected load changers with zero position and shutdown.
Technical specifications:
Frequency: 100-1000 strokes/minute
Load: 2 x 45 g
Stroke: 0-40 mm
Load from above: 450 N each
You can find more items - new and used - in our shop!
International shipping costs upon request!
Discover more used machines
Listing

1,867 km
Binder KBF 240 climate chamber
BinderKBF 240
Call
Condition: excellent (used), Chamber in very good condition
Binder climate chambers are used to test material behavior under constant humidity and temperature conditions.
These devices operate within a temperature range from 0°C to 70°C and a humidity range from 10% to 80% relative humidity.
The distinguishing feature of the Binder KBF series is absolutely reliable stability testing and precise maintenance of constant climate conditions.
Accurate climatic control makes these chambers ideal for stability testing.
The climate chamber is based on a modular design, and the interior is lined with stainless steel for easy cleaning.
Thanks to the APT.line™ preheating technology, the circulation of air throughout the usable volume is smooth and even.
Humidity levels can be precisely regulated and fully adapted to specific requirements.
Key features:
- Temperature range: 0°C to 70°C
- Humidity range: 10% to 80% relative humidity
- APT.line™ preheating chamber technology
- Humidity control with a capacitive humidity sensor and steam humidification
- Airtight inner doors made of safety glass (ESG)
- Corrosion prevention on the glass with special TIMELESS coating
- Interior chamber made entirely of stainless steel
- 2 stainless steel wire shelves
- 30 mm access port with silicone plug, left side
- 4 robust castors, two with brakes, from 240 L capacity upwards
Hedpfxsxnw Eqj Aacsnu
Listing

1,034 km
Climate test chamber with humidity
WeissWK3-340/70 -70°C bis +180°C
Call
Condition: excellent (used), Type: WK3-340/70
Weiss Climate Test Chamber, Water-Cooled
Control Unit: “Touch Panel”
All control and operating commands can be triggered simply by touching the function symbols on the “Touch Panel” control unit.
Adjustable Feet
The test chamber is equipped with adjustable feet to compensate for uneven floors and to ensure sufficient ventilation of the machine section.
Feed-Throughs
The test chamber is fitted with feed-throughs on both the left and right sides. These allow measuring cables and test devices to be routed into the test chamber. Feed-throughs included in the basic configuration:
R1: nominal width 125 mm
L1: nominal width 85 mm
Volume: 335 liters
Test Chamber Internal Dimensions:
Height: 750 mm, Width: 580 mm, Depth: 765 mm
External Dimensions:
Height: 1775 mm, Width: 870 mm, Depth: 1600 mm
Specifications for Temperature Tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temperature deviation over time: ± 0.1 to ± 0.5 K
Temperature uniformity spatially: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Specifications for Climate Tests:
Temperature range: +10°C to +95°C
Dew point range: –3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature uniformity spatially: ± 0.5 to ± 1 K
Humidity deviation over time: ± 1 to ± 3% RH
Operating Data:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Protection: 16 A slow-blow fuse, to be provided onsite
Hodpfxsxmg Sde Aacsnu
Refrigerant: R-452A/R23
Weight: approx. 585 kg
For your security as a buyer, please note the following information!
The following procedures are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Technical data, information and specifications are subject to change and errors.)
If you have any further questions, we will be happy to assist you by phone.
Listing

1,027 km
Large-scale climate test chamber
VötschVCZ 04032
Call
Condition: good (used), Large-scale system for climate tests with S!MCON control
Design
The system consists of the following main components:
- Walk-in, insulated test room
- Air treatment room
- Machine unit
- Air conditioning system
- Control cabinet
Test room
The fixtures in the test room are made of corrosion-resistant material.
The test room can be illuminated, is walk-in, and has a condensate and cleaning drain.
Air treatment room
The air treatment room is located behind the air baffle in the insulated interior.
It contains the following components necessary for temperature control and is accessible via easily removable panels.
- Test room fans
- Heat exchangers
- Electric heaters
- Ventilation and exhaust system
- Temperature sensors
In the air treatment room, the air is tempered (cooled/heated), humidified and dehumidified, and circulated by fans.
The air is drawn in under the ceiling and expelled at floor level.
Sensors
The temperature and humidity sensors are located behind the air baffle in the air treatment room.
Hodpfow U Sv Eex Aacjnu
Machine Unit
The machine unit, consisting of refrigeration units, supplies the air treatment room with the required energy.
Climate System
The climate system consists of:
- Steam humidifier
- Dehumidification evaporator
Technical Data
Test chamber volume: approx. 32 m³
Direct temperature range: -40 to +100°C
Temperature fluctuation over time in the center of the usable space: +/- 0.5 to +/- 1
Temperature change rate
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min
Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% RH
Dew point range: 5 to 93°C
Temperature fluctuation: +/- 5°C
Humidity fluctuation: +/- 3 to +/- 5% RH
Cooling water specifications
Connections
Inlet: 2 x 1 1/2" RH
Return: 2 x 1 1/2" RH
Consumption at full load: max. 16 m³/h
Maximum load on the test chamber floor: 10,000 N/m²
Nominal voltage: 3/N / PE AC 400 V 50 Hz
Nominal power: 97 kW
Nominal current: 148 A
Dimensions:
Test chamber: Width 3.60 m, Height 2.20 m, Depth 5 m
Climate chamber divided for transport at a specified location (approx. 2.50 m).
Find more items – new and used – in our shop!
International shipping costs on request!
Listing

1,034 km
Climate chamber with humidity, 100 liters
WeissWKL 100/40 -40...+180°C
Call
Condition: excellent (used), Type: WKL 100/40
Climate Test Chamber, Air-Cooled
with Humidity Control, -40 to +180°C
Specifications for Temperature Testing:
Temperature Range: -40 to +180°C
Temperature stability at steady state:
Temporal fluctuation in center of workspace: ±0.3 to ±1 K
Spatial deviation: ±0.5 to ±2 K
Rate of temperature change:
Heating: 3.5 K/min
Cooling: 5 K/min
Heat compensation capacity: max. 1100 W
Specifications for Climatic Testing:
Humidification System Data
Reservoir capacity: approx. 13 l
Water quality: Demineralized
pH value: 6 – 7
Conductivity: max. 20 μS/cm
Water consumption at constant temperature +40°C, 92% r.H.: 2 l / 24 h
Temperature range: +10 to +95°C
Humidity range: 10 to 98% r.H.
Temperature and humidity variation (steady state):
Temporal temperature fluctuation in center of workspace: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temporal humidity fluctuation in center of workspace: ±1 to ±3% r.H.
Mechanical Load Data:
Maximum load on chamber floor: 25 kg
Per shelf: 10 kg
Total shelf load: 50 kg
Access port: 50 mm diameter
Interfaces:
Ethernet interface (RJ45), USB interface
Operational Data:
Chamber lighting: Halogen bulb 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 3.0 kW
Rated current: 13.0 A
Required fuse: 16A slow blow
Protection class:
Control cabinet IP 22 and operator panel IP 54
Heat Emission for Air-cooled Test Chambers:
Max. heat emission to ambient: 2000 W
Noise Measurement:
Sound pressure level (free field), measured at 1 m in front and 1.6 m high: approx. 56 dB(A)
Chamber Volume: approx. 100 liters
Weight: 190 kg
Refrigerant: R404A
Hnjdjxhf Erepfx Aacsu
Important Safety Information for Buyers:
The following procedures are performed in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Changes and errors in technical data and specifications reserved!)
For further questions, we are happy to assist you by phone.
Listing

1,027 km
Climate test chamber
EspecPR-3KP
Call
Condition: good (used), operating hours: 75,383 h, Espec PR-3KP Environmental test chamber -20 to +100 °C
Features:
Manufacturer: Espec
Type: PR-3KP
Temperature range: -20 to +100 °C
Humidity: 20 to 98 % rH
Refrigerant R-404A:- CFC-free - ozone-friendly
Operating hours: 75383
Dimensions:
External dimensions: HxWxD= 1680 x 1050 x 1200 mm
Chamber dimensions: HxWxD= 850 x 600 x 800 mm
Hedpfx Aewbz Hhjacsnu
Further items in other sizes - new and used - can be found in our store!
International shipping costs on request!
Listing

1,034 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test chamber volume: 335 litres
Performance for temperature testing:
Temperature range: -70 to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Performance for climate testing:
Temperature range: +10 to +95°C
Temporal temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Temporal humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50 % RH and +95°C / 50 % RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10%, 50 Hz
Nominal power: 10 kW
Nominal current: 21 A
Hnjdpoxgd Rdofx Aacsu
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R-404A / R-23
For your safety as a buyer, please note the following information!
The following steps are carried out on all our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors reserved!)
Feel free to contact us by phone for any further questions.
Listing

1,034 km
Climate test chamber 900 liters
CTSCS-70/900 -70...+180°C
Call
Condition: used, Type: CS-70/900
CTS Climate Test Chamber with Humidity, water-cooled
(converted to R-452a refrigerant)
Temperature range: -70°C to +180°C
Humidity range: 10–98% RH
Test chamber internal dimensions: Height approx. 870 mm / Width approx. 1000 mm / Depth approx. 1000 mm
External dimensions: Height approx. 1950 mm / Width approx. 1200 mm / Depth approx. 2220 mm
Control cabinet dimensions: Height approx. 2100 mm / Width approx. 800 mm / Depth approx. 400 mm
Test chamber volume: 900 liters
Refrigerant: R-452a / R23
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Connected load: 21.2 kW, Rated current: 35.7 A
Chamber weight: 900 kg
Control cabinet weight: 150 kg
Hedpsxb Dm Ijfx Aacsnu
Important safety information for buyers:
The following steps are carried out on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilled with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors reserved!)
For any further questions, please contact us by phone.
Listing

1,034 km
Climate test chamber 335 liters with humidity
VötschVC 4034 -40°C..+180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Hodpfx Aasxbrkhjconu
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,034 km
Climate test chamber with solar simulation
Atlas / WeissSolarClimatic SC-340
Call
Condition: excellent (used), Atlas
Type: SC 350 MHG
Atlas Solar Climatic Test Chamber, Air-Cooled
For sale is an ATLAS SC-340 MHG SolarClimatic Test Chamber
(climatic chamber with solar simulation via MHG lamp).
The device is suitable for carrying out standardized weathering and aging tests under the combined influence of radiation, temperature, and climate.
Features & Highlights:
- Precise temperature and humidity control
- Integrated humidification system with water reservoir
- Cooling via water or air system (optional)
Hnodpfx Ajxbd Raeaceu
- Feed-throughs available for measuring leads
- Control via control panel or interfaces (RS232, etc.)
- Sturdy test chamber floor, loadable up to 60 kg (optionally reinforced to 150 kg)
General Data:
Model: SC 340 MHG
Test chamber volume: approx. 335 liters
Cabinet weight: approx. 500 kg
Irradiation unit weight: approx. 65 kg
Technical Data:
Test volume: 340 l (internal dimensions 580 × 765 × 750 mm)
External dimensions (W×D×H): 865 × 1,595 × 2,180 mm
Light source: 1 × 1,200 W MHG lamp
Irradiance: 800–1,200 W/m²
Illuminated area: approx. 3,300 cm²
Weathering spectrum: 300–3,000 nm, compliant tests according to DIN 75220, IEC 60068-2-5, MIL-STD-810F
Temperature range with irradiation: –20 °C to +100 °C (±1 K)
Temperature range without irradiation: –30 °C to +100 °C (±0.1–0.5 K)
Heating/Cooling rates: 3.0 K/min (heating), 2.5 K/min (cooling, without irradiation)
Noise level: approx. 58 dB(A) at a distance of 1 m
Power supply: 400 V, 3/N/PE, 50 Hz
Power consumption: max. 6.2 kW, 16 A
Refrigerant: R-404A
Weight: approx. 565 kg
Information for your safety as a buyer!
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers are subjected to a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Specifications and technical details subject to change and errors reserved!)
Feel free to contact us by phone for any further questions.
Listing

1,034 km
Climate test chamber -10°C to +90°C
VötschVC 0018
Call
Condition: used, Vötsch
Model: VC 0018
Air-cooled climate test chamber
Test chamber dimensions: Width 580 x Depth 450 x Height 750 mm
Housing dimensions: Width 865 x Depth 1150 x Height 1780 mm
Test chamber volume: approx. 190 liters
Performance data for temperature tests:
Temperature range: -10 °C to +90 °C
Temperature deviation in steady-state, according to IEC 60068-3-5,
dependent on test chamber temperature
time-wise ±0.1 to ±0.5 K
spatially ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 0.6 K/min.
Cooling: 0.3 K/min.
Heat compensation in the range +20 °C to +50 °C: 200 W
Calibration values: +4 °C and +90 °C
Performance data for climatic tests:
Temperature range: +10 °C to +90 °C
Temperature deviation in steady-state, according to IEC 60068-3-5,
dependent on test chamber temperature
time-wise ±0.1 to ±0.3 K
Hnodpew Swrtjfx Aaceu
spatially ±0.5 to ±1.0 K
Humidity range: 10% to 98% r.h.
Electrical connection:
Rated voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 1.7 kW
Rated current: 9.5 A
(Neutral conductor plug: loaded)
Schuko approx. connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Weight: approx. 380 kg net
Refrigerant: R-134A
Buyer Information for Your Safety!
The following procedures are carried out on our climate chambers prior to sale:
1. Function check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
Technical specifications and information subject to change and errors!
Feel free to call us with any further questions.
Listing

1,034 km
Salt spray chamber / climate cycling device
WeissSC/KWT 450
Call
Condition: excellent (used), White
Type: SC/KWT 450
Salt Spray Chamber
Technical Specifications:
Test chamber capacity: 450 liters
Max. load: 100 kg
Brine storage tank: 180 liters
External dimensions: Height 920 mm, Width 1930 mm, Depth 800 mm
Test chamber dimensions: Height 740 mm, Width 850 mm, Depth 570 mm
Hodpjw Strcsfx Aacsnu
Areas of application:
Corrosion tests:
Salt spray test: Room temperature up to +50°C
Condensation test: Room temperature Up to +45°C
Humidifier +75°C
Temperature stability
The temperature deviation over time is ± K.
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power 2.0 kW, Rated current 8.7 A
Combination:
Salt spray test SS: DIN 50021
Condensation test KFW: DIN 50017
Normal climate (ventilation): DIN 50014
Weight: 180 kg
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

1,034 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-15 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-15
Vötsch Climate Test Chamber, Water-Cooled
Temperature Test Data:
Temperature range: -70°C to 180°C
Temporal temperature deviation at center of workspace: ±0.3 to ±0.8 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 16 K/min
Cooling: 14.5 K/min
Climate Test Data:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temporal temperature deviation at center of workspace: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation at center of workspace: ±1 to ±3% RH
Maximum heat compensation: 8000 W
Enclosure dimensions:
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
External dimensions without hinges and door lock:
Hnodpfx Aaowvgwbecsu
Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
Internal dimensions:
Height: 950 mm, Width: 1100 mm, Depth: 950 mm
Test chamber volume: approx. 1300 liters
Feedthroughs:
The test chamber is equipped with feedthroughs on both the right and left sides. These allow for test leads and testing devices to be routed into the chamber.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test chamber illumination:
Halogen bulb 24V, 50W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 44.0 kW
Rated current: 63.0 A
Customer-provided fuse: 100 A slow-blow
Maximum heat output to the environment: 2.2 kW
Permissible test item weight:
Total load on shelf supports: 100 kg
Test chamber floor: 150 kg, Removable shelf: 50 kg
Refrigerants: R 404A/R 23
Weight: 1900 kg
For your security as a buyer, please note:
The following steps are carried out in advance on our chambers offered for sale:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in the technical data and specifications!)
We are happy to answer any further questions by phone.
Listing

1,034 km
Climate test chamber 600 liters with humidity
WeissWK3-600/70 -70°C bis +180°C
Call
Condition: excellent (used), Weiss
Model: WK3-600/70
Climate Test Chamber, Water-cooled
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temperature change rate:
Heating: 4.0 K/min
Cooling: 2.5 K/min
Temperature deviation:
Temporal: ±0.1 to ±0.5 K
Spatial: ±0.5 to ±1.5 K
Heat compensation: max. 2500 W
Hodsw Nqhpjpfx Aacsnu
Specifications for climate testing:
Temperature range: +10 to +95 °C
Dew point temperature range: -3 to +94°C
Humidity range: 10 to 98% r.h.
Temperature deviation (temporal): ±0.1 to ±0.3 K
Temperature deviation (spatial): ±0.5 to ±1 K
Humidity deviation (temporal): ±1 to ±3% r.h.
Temperature uniformity (spatial): ±0.5 to ±1.0 K
Heat compensation: max. 500 W
Test chamber volume: 600 liters
Test chamber dimensions (H x W x D): 950 mm x 800 mm x 800 mm
External dimensions (H x W x D): 1998 mm x 1000 mm x 1745 mm
Feedthrough diameters: NW 125 mm and NW 50 mm
Operating data:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 9.1 kW
Nominal current: 19.0 A
Refrigerant: R 452A & R23
Weight: 680 kg
Important safety information for buyers!
The following procedures are carried out on all chambers we offer prior to delivery:
1. Functional check and replacement of necessary components
2. If necessary, the chamber is refilled with refrigerant in compliance with applicable laws
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Specifications subject to change and possible errors!)
If you have further questions, feel free to call us.
Listing

1,034 km
Climate test chamber 600 liters
WeissWK3-600/70 -70°C bis +180°C
Call
Condition: good (used), Weiss
Type: WK3-600/70
Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
Temperature change rate:
Heating: 4.0 K/min
Cooling: 2.5 K/min
Temperature deviation:
Over time: ±0.1 to ±0.5 K
Spatially: ±0.5 to ±1.5 K
Hnedpfxow Inmmj Aacou
Heat compensation max.: 2,500 W
Specifications for Climate Testing:
Temperature range: +10 to +95 °C
Dew point temperature range: -3 to +94°C
Humidity range: 10 to 98 % rH
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1 K
Humidity deviation over time: ±1 to ±3 % rH
Temperature uniformity (spatial): ±0.5 to ±1.0 K
Heat compensation max.: 500 W
Test chamber volume: 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1,998 mm, Width 1,000 mm, Depth 1,745 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19.0 A
Refrigerant: R404A & R23
Weight: 680 kg
Important information for you as the buyer:
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications subject to change. Errors and omissions excepted!)
If you have any further questions, we are happy to answer them by phone.
Listing

1,034 km
Salt spray chamber / climate cycling device
WeissSC/KWT 450
Call
Condition: excellent (used), Weiss
Type: SC/KWT 450
Salt Spray Chamber
Technical Data:
Test chamber volume: 450 liters
Maximum load: 100 kg
Brine reservoir: 180 liters
External dimensions: Height 920 mm, Width 1930 mm, Depth 800 mm
Test chamber dimensions: Height 740 mm, Width 850 mm, Depth 570 mm
Hnedpfew Hz Trex Aacju
Applications:
Corrosion tests:
Salt spray test: Ambient temperature up to +50°C
Condensation water test: Ambient temperature up to +45°C
Humidifier +75°C
Temperature stability
The temporal temperature deviation is ± K.
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 2.0 kW Rated current: 8.5 A
Combination:
Salt spray test SS: DIN 50021
Condensation water test KFW: DIN 50017
Standard climate (ventilation): DIN 50014
Weight: 180 kg
Condition: used
Scope of delivery: (See picture)
(Subject to technical modifications and errors! All provided data are subject to change!)
For further questions, please feel free to contact us by phone.
Listing

1,034 km
Climate test chamber -10°C to +90°C
VötschVC 0018
Call
Condition: used, Vötsch
Model: VC 0018
Climate Test Chamber, Air-Cooled
Test Chamber Dimensions: Width 580 x Depth 450 x Height 750 mm
External Dimensions: Width 865 x Depth 1150 x Height 1780 mm
Test Chamber Volume: approx. 190 liters
Specifications for Temperature Testing:
Temperature Range: -10°C to +90°C
Temperature Deviation at steady state, according to IEC 60068-3-5,
depending on chamber temperature
over time: ±0.1 to ±0.5 K
spatial: ±0.5 to ±2.0 K
Temperature Change Rate according to IEC 60068-3-5
Heating: 0.6 K/min
Cooling: 0.3 K/min
Hnsdsw Hz S Uopfx Aaceu
Heat compensation in the range +20°C to +50°C: 200 W
Calibration Points: +4°C and +90°C
Specifications for Climate Testing:
Temperature Range: +10°C to +90°C
Temperature Deviation at steady state, according to IEC 60068-3-5,
depending on chamber temperature
over time: ±0.1 to ±0.3 K
spatial: ±0.5 to ±1.0 K
Humidity Range: 10% to 98% RH
Electrical Connection:
Rated Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 1.7 kW
Rated Current: 9.5 A (neutral conductor plug loaded), Schuko approx. connection cable: 3.5 m
Protection: 16 A slow-blow, provided by the customer
Weight: approx. 380 kg net
Refrigerant: R 134A
For your safety as a buyer, please note the following information!
The following points are carried out on all climate chambers we offer prior to delivery:
1. Functional check and replacement of necessary components
2. If necessary, a refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications and technical data are subject to change and errors are excepted!)
We are happy to answer any further questions you may have by phone.
Trust Seal
Dealers certified through Machineseeker

Listing

1,034 km
Climate test chamber 1540 liters
WeissWK1-1500/40 Temp. -40°C bis +180°C
Call
Condition: used, Weiss
Type: WK1/1500/40
Weiss Climate Test Chamber, Air-Cooled with Humidity Control
(converted to use refrigerant R-452a)
Temperature range: -40°C to +180°C
Cooling rate approx. 2.5 K/min, heating rate approx. 3.5 K/min
Temporal temperature deviation at center of test space: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature range: +10°C to +95°C
Humidity range: 10% to 98% r.H.
Temporal temperature deviation at center of test space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Heat compensation
In the range of +25°C to +95°C, at a relative humidity up to 90%: 500 W
Hnodpfew Hcttjx Aaceu
Test chamber dimensions: Height: 950 mm, Width: 1100 mm, Depth: 1475 mm
External dimensions: Height: 2005 mm, Width: 1300 mm, Depth: 2450 mm
Test volume: approx. 1540 liters
Test chamber lighting: Halogen bulb 12V, 50W
Rated voltage: 3/NPEAC 400V ±10% 50Hz
Rated power: 11.5 kW, Rated current: 22.0 A
Fuse on site: 32A slow-blow
Protection class (control cabinet and operator panel): IP 54
Refrigerant: R-452a
Weight: 920 kg
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run, monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and errors excepted!)
If you have further questions, we will be happy to answer them by phone.
Listing

1,034 km
Climate test chamber with humidity, 306 liters
EspecPSL-2KPH -70°C bis +150°C
Call
Condition: excellent (used), Espec
Type: PSL-2KPH
Thermo TEC
Espec Temperature and Climate Test Chamber, Air-Cooled
Hnedpfx Aajw D Dgvscou
Temperature range: -70°C to +150°C
Humidity range: 20 to 98% rH
Temperature/Humidity Fluctuations: ± 0.3°C / ± 2.5% rH
Temperature/Humidity Stability: ± 0.5°C / ± 3% rH
Heat-up time: from -70°C to +150°C in 50 min
Cool-down time: from +20°C to -70°C in 80 min
Test chamber dimensions: width 600 mm x height 850 mm x depth 600 mm
External dimensions: width 1010 mm x height 1690 mm x depth 1173 mm
Test chamber volume: 306 liters
Refrigerants: R-404A, R-508A
Stainless steel construction
Connection: AC 400V 3~ 50/60 Hz Max. 18 A
Rated power: 1.5 kW
Net weight approx. 400 kg
For your safety as a buyer, please note the following information!
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New charge with legally compliant refrigerant
3. After successful inspection, the chambers undergo a test run, monitored with calibrated instruments.
Condition: used
Scope of delivery: (see photo)
(Technical data and specifications may be subject to change and errors!)
For further questions, please feel free to contact us by phone.
Listing

1,034 km
Climate test chamber with humidity, 800 liters
EspecPSL-4KPH -70°C bis +150°C
Call
Condition: excellent (used), Espec
Type: PSL-4KPH
Espec Temperature and Climate Test Chamber, Air-Cooled
There is a small dent at the top edge of the door (see photo).
The door closes perfectly, the seal is intact, and the climate chamber operates without any technical faults.
The dent is purely cosmetic and does not affect function, sealing, or control accuracy in any way.
Temperature range: -70°C to +150°C
Humidity range: 20 to 98% relative humidity
Temperature/Humidity fluctuations: ±0.3°C / ±2.5% r.H.
Temperature/Humidity stability: ±0.5°C / ±3% r.H.
Heating/Cooling rates and times:
- Heating time: within 30 min from +20 → +100 °C
- Cooling time: within 115 min from +20 → –40 °C
- Heating rate: 3.0 °C/min
- Cooling rate: 1.0 °C/min
Test chamber dimensions: Width 1000 mm x Height 1000 mm x Depth 800 mm
External dimensions: Width 1410 mm x Height 1983 mm x Depth 1593 mm
Port with silicone plug: 100 mm
equipped with RS232 interface
Test chamber volume: 800 liters
Refrigerants: R-404A, R-508A
Stainless steel construction, AC 400 V 3φ, 50Hz 31 A
Hnodpfxewz Er Uj Aacju
Net weight approx. 720 kg
For your safety as a buyer, the following measures are performed in advance on our offered chambers:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Upon successful inspection, the chambers undergo a test run monitored with calibrated devices.
Condition: used
Scope of delivery: (see photo)
(Subject to change and error in technical data and specifications!)
We are happy to answer further questions by phone.
Listing

1,034 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-10 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-10
Vötsch Climate Test Chamber, Water-cooled
Specifications for Temperature Testing:
- Temperature range: -70°C to +180°C
- Temporal temperature deviation at the center of the usable test volume: ±0.3 to ±0.8 K
- Spatial temperature deviation: ±0.5 to ±2 K
- Temperature gradient: 1 to 4 K
- Temperature change rate:
- Heating: 11 K/min
- Cooling: 10.5 K/min
Specifications for Climatic Testing:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98% RH
- Temporal temperature deviation at the center of the usable test volume: ±0.2 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1 K
- Temperature gradient: 1 to 2 K
- Temporal humidity fluctuation at the center of the usable test volume: ±1 to ±3 % RH
Technical Data:
- External dimensions (with hinges and door lock):
- Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
- External dimensions (without hinges and door lock):
- Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
- Internal chamber dimensions:
- Height: 950 mm, Width: 1100 mm, Depth: 950 mm
- Test chamber volume: approx. 1300 liters
Feedthroughs:
- The chamber is equipped with feedthroughs on both the right and left sides, allowing measurement cables and test devices to be routed into the test space.
- 1 x R1 NW 125 mm
- 1 x L1 NW 50 mm
Test Chamber Lighting:
- Halogen bulb 24 V, 50 W
Electrical specifications:
- 3/N/PE AC 400V ±10% 50Hz
- Rated power: 34.0 kW
- Rated current: 50.0 A
- Fuse (to be provided on site): 100 A slow-blow
- Max. heat emission to environment: 2.2 kW
Permissible Test Specimen Weight:
- Total load on grate supports: 100 kg
- Chamber floor: 150 kg; Inserted rack: 50 kg
Refrigerants:
- R 404A / R 23
Weight: 1600 kg
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, recharge with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in technical data and information!)
For further questions, please feel free to contact us by phone.
Hnsdpfxswynmxo Aaceu
We make it easier for you to find: "climate chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Climate Chamber (5,835)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month