Used Climatic Chamber for sale (5,380)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Germany
1,034 km
Chamber for parametric testing
S & A4365A
Call
Condition: excellent (used), S & A Test Chamber
Here we offer you a S & A test chamber for parametric testing.
Temperature range
-55 ° C to 200 ° C (LCO2)
-65 ° C to 200 ° C (LN2)
Temperature change rate
Iodpfx Agon Arl Ss Usht
15° C / min (Standard Option)
60° C / min (Fast Option)
Stability
± 0.2 ° C (including effects of mains voltage, ambient temperature
between 15° and 45° C and aging)
Uniformity
± 1.0 ° C Max from -65 ° C to -55 ° C
± 0.5 ° C Max from -55 ° C to + 125 ° C
± 1,0 ° C Max from + 125 ° C to + 200 º C
Coolant: LCO2
Chamber can be controlled remotely via IEEE bus or
RS232C interface
Weight approx. 61 kg
Type: 4365A
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Mönchengladbach
1,029 km
Lifting head flat chamber
Hohner52/8
Call
Condition: used, Hohner Stitching Head 52/8
Condition as per photo
Ijdpexwx Ulofx Ag Ujht
Listing
Borken
1,034 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Iedsm Ak H Hepfx Ag Ueht
Weiss Temperature Shock Test Cabinet Water Cooled
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot/cold chamber 10 sec.
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Width ( without and with door hinge ) without....approx. 1820 mm with....approx. 1850 mm
Depth ( without and with test room door ) without....ca. 900 mm with....ca. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Mönchengladbach
1,029 km
Press heads flat chamber
Hohner52/8S
Call
Condition: new, Hohner stitching heads 52/8S
condition as shown in the photo
Iodjxwx A Aepfx Ag Usht
Listing
Borken
1,034 km
Environmental test chamber -70°C - +180°C Humidity
ThermotronSM-8-8200
Call
Condition: excellent (used), Here we offer you Thermotron environmental test chamber.
Thermotron Environmental Test Chamber Water Cooled
Working volume: 227 liters
Temperature uniformity: All models 0.7°C
Temperature range: -70°C to + 180°C
Temperature control tolerance: All models 0.3°C
Shipping weight: approx 400 kg
Internal dimensions width 610 mm x depth 610 mm x height 610 mm
Outer dimensions width 890 mm x depth 1240 mm x height 1850 mm
Humidity range: All models 10% to 98% RH
Humidity control: All models 2.5% RH
Iedpfsmhfr Iex Ag Ujht
Heating capacity in minutes -65º to 71ºC: 17
Heating power in minutes -65º to 180ºC: 43
Heating power in minutes -40º to 85ºC: 16
Electrical requirements in full load amplifiers 230/3/60: 19
Electrical requirements in full load amplifiers 230/1/60: 25
Electrical requirements in full power amplifiers 220/1/50: 27
Cooling capacity in minutes 85º to -40ºC: 32
Cooling capacity in minutes 71º to -65ºC: 54
Cooling capacity in minutes 180º to -65ºC: 72
Compressor size: (2) -2 Hp
Operating voltage: 400V 16.7 A
Type: SM-8-8200
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Discover more used machines
Listing
Borken
1,034 km
Salt spray chamber
KöhlerHK500
Call
Condition: excellent (used), Here we offer you a Köhler salt spray chamber.
Salt spray chambers:
diverse testing possibilities from salt spray test to fully automatic alternating test
easy operation by graphical menu guidance
customized versions for many applications
easy operation via touch panel
internal dimensions W x D x H (without hood) 1080 x 675 x 580 mm
external dimensions W x D x H 1940 x 900 x 1220 mm
Test chamber capacity 500 liters
Chamber temperature Rt +5 - 60°C
Humidifier temperature Rt +5 - 75°C
Mains connection 230V 1P 50/60Hz 2000W
Compressed air 4,5 - 8.0 bar / 3Nm³/h
Brine supply 140 liters
Stainless steel version
Refurbished and converted to Comfort control
- Renewal of all electrical components
Isdpfx Aenr Hi Ssg Usht
- Renewal of all hose connections
Type: HK 500
400 Kg
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Climate chamber
CTSCW-40/16
Call
Condition: excellent (used), CTS climate chamber climate test cell
Here we offer a CTS climate chamber climate test cell.
Available from mid-January 2023!
Water cooled
Height adjustable!
Footprint approx. (W x D x H): 3755x 3470x 2480
Test area approx. (W x D x H): 2500x 2720x 2200
Test space volume: approx. 15m³
Isdpeip Dp Sofx Ag Uoht
Temperature range: -40°C to +140°C
Temperature deviation 1 K temporally
Temperature change speed in the average without heat radiation Measured in the supply air
heating: 2 K/min
Cooling: 1 K/min
from +110°C to -35°C
Climatic tests:
Temperature range: +10 °C to +90 °C
Humidity range . +30 % to +95% r.H.
dew point range : +5°C to 89°C
temperature deviation 0,5 K temporal
Humidity deviation ±1- ±3% r.H. temporal
nominal voltage: 400V 3/N, PE, 50 Hz
rated power: 53,5 KW
Rated current: 92,3 A
Compressor: S6J-16.2
+ chiller
Refrigerant: R404A
Weight 5500 kg
Type: CW-40/16
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Here we offer shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
Temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation temporally in useful chamber center ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -65°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Iedpfx Asi Az Egsg Ueht
Outer dimensions width 930mm depth 2115mm height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Operating hours: 27.903 hrs.
Weight: 1000 kg
For you as a buyer, the following information for your safety!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: HT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
UV weathering chamber -20°C to +80°C
WeissUV200SB 200 Liter
Call
Condition: excellent (used), Weiss UV200SB Weathering Chamber / UV Aging Test Device
Air-cooled, approx. 200 liters
For sale is a Weiss UV200SB weathering chamber, a high-quality test device for simulating sunlight and weathering effects.
This device is used for accelerated aging tests on plastics, paints, coatings, and other materials according to common standards (e.g., DIN EN ISO 4892-3).
Technical Details
UV Spectrum: approx. 290–450 nm (UVA/UVB)
Lamp type: Fluorescent UV lamps
Temperature range (UV phase): approx. +20 to +80 °C
Climate cycling: Alternating between UV irradiation, condensation, and spray phases
Humidity range: approx. 10% to 95% r.H. (relative humidity) at temperatures above approx. +10 °C
Temperature change rate: approx. 3 K/min
Test chamber dimensions: Height 750, Width 650, Depth 400 mm
External dimensions: Height 1800, Width 920, Depth 1345 mm
Voltage: 3/N/PE AC 400V +10% 50Hz
Rated power: 9.0 kW
Rated current: 15.0 A
Refrigerant: R 404A
For your safety as a buyer! The following points are always carried out on our chambers in advance:
1. Function check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
Ihodpexdl Ixsfx Ag Ujt
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors reserved!)
Further questions can be answered for you by phone.
Listing
Borken
1,034 km
Climate test chamber with humidity 1000 liters
CTSC-40/1000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: C-40/1000
CTS climatic test chamber
Condenser chiller air-cooled
Control:
32 bit controller
LCD control panel
Digital display of setpoints and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature test:
Temperature range: -40°C to +180°C
Temperature change rate
Heating speed 2.0 K/min
Cooling rate 2.5 K/min
Temperature deviation ± 0.1 to ± 0.3 K in time
Heat radiation:
approx. 2500 W at +20°C
approx. 2500 W at ± 0°C
Ihodpfx Ajru Dzusg Uet
approx. 1500 W at -20°C
Climate Working range:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Dew point range I +7 to +94°C
Dew point range II -10 to +7°C
Temperature deviation ± 0.1 to ± 0.3 K in time
Humidity constancy I, temporal ± 0.5 to ± 1.5 % r.h.
Humidity constancy II, temporal ± 1 to ± 3 % r.h.
Panorama window 570 x 710 mm
Test chamber dimensions Width 1000 mm Depth 1100 mm Height 900 mm
External dimensions Width 1270 mm Depth 2220 mm Height 1950 mm
Test chamber volume 1000 liters
Pipe feed-throughs, ø 50
Electrical connection: 400 V +6/-10% 3/N, PE 50 Hz
Connected load: 8.4 kW Rated current: 12.4 A
Refrigerant: R-404A
Weight: 800 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Temperature test chamber 680 liters
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Call
Year of construction: 2010, condition: excellent (used), Here we offer you a Heraeus Vötsch temperature test chamber.
Vötsch temperature test chamber VLM 3068/S air-cooled
(building material test chambers loaded from above)
Control panel
The control panel is mounted on a console on the temperature test chamber. By
control and operating commands can be triggered by simply touching the function symbols.
can be triggered. The operating instructions for the control panel are enclosed
Main switch
The main switch is located at the front of the temperature test chamber.
Air treatment room
The air treatment room is located in the test room
and contains the components required for temperature control.
In the air treatment room, the air is tempered (cooling/heating) and circulated by the test room fan.
circulated by the test room fan. The air is sucked in at the center of the side wall and
enters the test chamber again via the air baffles on the long sides.
Feed-throughs
The temperature test chamber can optionally be equipped with feed-throughs. Through these
can be used to route cables and test equipment into the test chamber.
Entry port front 2 x 82 mm ∅ rear 1 x 85 mm ∅
Internal dimensions Width 2000 mm Depth 570 mm Height 600 mm
External dimensions Width 3000 mm Depth 870 mm Height 1060 mm
Technical data:
Data for mechanical load:
Max. load with test material
Test area floor
(evenly distributed over the surface) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Ihodpfxorbiyfo Ag Uot
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Nominal voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Customer fuse 16A slow-blow
Temperature test chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Walk-in climate chamber with humidity control
RS-SimulatorenKKM 110/45 -40°C bis +120°C
Call
Condition: excellent (used), RS-Simulators
Type: KKM 110/45
Manufacturer: RS-Simulators, water-cooled
Climatic chamber – Available from September/October!!
Ihjdowwg Uvopfx Ag Ujt
Climatic chamber 110m³ including condenser
The KKM 110/45 model belongs to the TKM/KKM modular construction line from RS-Simulators – a modular climatic chamber that is assembled on site.
This design offers:
Modularity: Individual segments are pre-assembled and set up at the customer’s location. This allows for easy retrofitting (increased depth or additional modules) and hassle-free relocation at a later date.
Technical data – Climatic chamber:
Manufacturer: RS-Simulatoren Prüf- und Messtechnik GmbH
Type: KKM 110/45
External dimensions: 6200 x 9400 x 3400 mm (W x D x H, including technical attachments)
Internal dimensions: 5900 x 7000 x 2960 mm (W x D x H)
Chamber door (double-leaf): 3600 x 2930 mm (W x H)
Personnel door (single-leaf) on side wall: 1880 x 900 mm (H x W)
Feedthroughs: 8 x Ø120mm (4x left & 4x right)
Windows: 1x (460 x 550mm) in the front chamber door, heated
1x (1260 x 1000mm) in the left side wall, heated
Temperature range: -40°C to +120°C
Temporal deviation: ± 0.8K – 1.5K according to DIN 50011 (empty test chamber)
Humidity range: 10% to 95%
Humidity tolerance: +/- 5.0%
Refrigerants: 2x R404A 52kg, 2x R23 17kg
Temperature change rate:
Heating: 1.0 K/min
Cooling: 1.0 K/min
Electrical specifications:
Voltage: 3x400V/N/PE
Current: 340A
Weight: approx. 2,000 kg
Important information for your safety as a buyer!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. Following successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Subject to technical changes and errors in the information provided!)
We are happy to answer any further questions by phone.
Listing
Borken
1,034 km
Temperature test chamber 1540 liters
VötschVT³ 4150 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VT³ 4150
Vötsch temperature test chamber
Air-cooled
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 11.5 kW Rated current: 22.0 A
Rate of change: Cooling approx. 3.5 K/min.
Ihodju Nh Rbspfx Ag Uet
Rate of change: Heating approx. 4 K/min.
Temperature test
Temperature range -40°C to + 180°C
Display plan
External dimensions: W x D x H approx. 1390 x 2380 x 1995 mm
Test chamber dimensions: W x D x H approx. 1100 x 1475 x 950 mm
Weight approx. 1020 kg / 1540 liters
Refrigerant R 404A
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Temperature test chamber
CTSTS -70/600-13
Call
Condition: used, CTS
Type: TS -70/600-13
Temperature test chamber, water-cooled
Type series: TS -70/600-13
Control system:
- 32 bit controller
- LCD control panel
- Digital display of setpoints and actual values
- Numerical input of setpoint values
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Test chamber volume: 600 liters
Test chamber dimensions: Height approx. 730 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions: Height approx. 2250 mm, width approx. 1300 mm, depth approx. 2475 mm
Temperature range: -70 to +180°C
Heating speed: 13 K/min at -40°C to +120°C
Cooling speed: 13 K/min at 120°C to -40°C
Temperature deviation: ± 0.1K temporal, ± 0.5 K spatial
Isdpfx Asvcyaweg Uoht
Electrical connection 400/3P/N/PE
Nominal power: approx. 27.8 kW
Nominal current: approx. 44.1 A
Compressor: 4TC-8.2Y/4PC-10.2Y
Refrigerant: R-404 A / R-23
Weight: 1350 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Temperature test chamber 600 liters
CTST-70/600 -70°C bis 180°C
Call
Condition: excellent (used), CTS
Climatic test chamber T-70/600 water-cooled
Temperature range: -70°C to +180°C
Ijdpfxevaxq Nj Ag Usht
Rated voltage: 400V 3/N PE 50 Hz
Rated power: 6.7 kW
Rated current: 10.2 A
Compressor: TFH2480Z/TFH2511Z Refrigerant R23/R404A
Control system:
-Microprocessor-controlled control and monitoring system
Simple, user-friendly terminal built into the door.
-Digital temperature setpoint and actual value display
Simple variation via +/- button
-Digital input for temperature in °C
-PLC compatible
-Up to 100 test programs possible
-RS 232 interface
-2 free switching channels for on-site
test material control
Insert grid:
Stainless steel, contact surface 820 x 710 mm
Load per grid max. 35 kg
Total load with max. grid configuration 100 kg
Cooling unit:
Water-cooled, low-noise, fully hermetic Infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
Temperature tests:
Temperature range -70 °C to+ 180 °C
Temperature deviation ±0.1 to 10.3 K in time
Rate of temperature change
according to DIN 50 011, part 12 measured in the center of the test room
Heating 2.5 K/min
Cooling 2 K/min
Heat radiation max. 1500 W at +20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions 850 x 830 x 850 mm (W x Dx H)
External dimensions 1050 x 1850 x 1900 mm (W x DxH)
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 6.7 kW
Rated current: 10.2 A
Protection class IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level < 62 dB(A)
Weight approx. 400 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Temperature test chamber 1000 liters
CTS - 70°C bis +180°CTS -70/1000-10 bis ca.10 K/min
Call
Condition: good (used), Type: TS -70/1000-10
For sale is a CTS temperature test chamber
Model: TS -70/1000-10
Cooling: water-cooled refrigeration unit
Compressor has been replaced!
Features:
- Multi-touch control system
- USB and Ethernet interfaces
- Cable feedthroughs for test cables: 4 × Ø 125 mm
- Safety temperature limiter
Applications:
- Environmental and longevity tests
- Thermal cycling tests (stress screening)
- Quality assurance and research & development
- Electronics, automotive, materials testing
Test chamber volume: 1,000 liters
Test chamber dimensions:
- Height: approx. 1,000 mm
- Width: approx. 860 mm
- Depth: approx. 1,100 mm
External dimensions:
- Height: approx. 1,950 mm
- Width: approx. 1,270 mm
- Depth: approx. 1,900 mm
Temperature range: -70°C to +180°C
Temperature deviation: ± 0.3 K over time
Isdpsxdi Ezjfx Ag Uoht
Temperature change rate: up to approx. 10 K/min
Electrical connection: 400V 3/N 50Hz
Rated power: approx. 23.1 kW
Rated current: approx. 40 A
Refrigerant: R404A / R23
Weight: 1,000 kg
For your peace of mind as a buyer, please note:
The following inspections and services are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if required
3. Leak test with certificate
4. Following successful checks, chambers undergo a documented test run
Condition: used
Scope of delivery: (See pictures)
(Specifications and technical data subject to change and errors excepted!)
We are happy to answer further questions by phone.
Listing
Borken
1,034 km
Temperature chamber
WEISSWT1-340/30
Call
Condition: excellent (used), Weiss temperature chamber
Here we offer Weiss temperature chamber.
Converted to R452a
Weiss temperature chamber air cooled
Temperature range: from - 30°C to 180°C
Temperature change rate cooling 1,6 K/min
Temperature change rate heating 2,1 K/min
Test chamber dimensions: Width 550 mm x depth 750 mm x height 800 mm
Housing dimensions: Width 800 mm x depth 1500 mm x heights 1800 mm
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4,9 kW Rated current 9 A
Refrigerant: R452a
Weight: 515 kg
Type: WT1-340/30
For you as a buyer the following information for safety!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Iedeic Rgfopfx Ag Uoht
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Chamber convection oven
EliogKU 300/09-06-06/2
Call
Condition: excellent (used), Eliog
Here we offer you a chamber air circulation furnace.
Usable space dimensions : height mm 900 / width mm 600 / depth mm 600
324 liters
Outer dimensions : height mm 1775 / width mm 900 / depth mm 953
Door leaf 1
Connected load: 3X400V 50 Hz 13 kVA
Heating power: 12 kW
Nominal temperature: 300°C
weight: 400 kg
Type: KU 300/09-06/2 K1051071
Iedpfxoifkiie Ag Uoht
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Temperature test chamber ex protected
CTST-30/950 Ex/I
Call
Year of construction: 2011, condition: excellent (used), CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
Iodpfx Agsihb Amo Ueht
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Listing
Borken
1,034 km
Climate test chamber with humidity
Weiss -72°C bis +180°CWK3-340/70
Call
Condition: excellent (used), Weiss
Type: WK3-340/70
Weiss Air-Cooled Climatic Test Chamber
Touch Panel Control Unit
All control and operating commands can be triggered by simply touching the function symbols on the touch panel control unit.
Adjustable Feet
Ihodpfx Aov Sr Hzog Ujt
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Plug-ins
The test chamber is equipped with plug-ins on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Penetration included in standard equipment
R1: NW 125 mm
L1: NW 85 mm
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Minimum temperature -72°C
Maximum temperature +180°C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 1.5 K
Temperature change rate, cooling 3 K/min
Temperature change rate, heating 3 K/min
Data for climatic tests:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Operating data:
Test room lighting: 2 x 24V, 50W halogen bulb
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Fuse: 16 A slow-blow (on-site)
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
For your safety, the following information is provided as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Shock test chamber +50 - 220°C -80 - +70°C
VötschVT 7012 S2 (6603)
Call
Condition: excellent (used), Here we offer Vötsch shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -80°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Ihjdpfx Ajn Arc Asg Uot
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions Width 470 mm Depth 650 mm Height 410 mm
External dimensions Width 930 mm Depth 2115 mm Height 1970 mm
Feedthrough ∅ 67mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V ±10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: VT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
1,034 km
Temperature test chamber
VötschVT³ 4150/S
Call
Condition: excellent (used), Vötsch
Type: VT³ 4150/S
Vötsch temperature test chamber
Water-cooled
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 11.5 kW Rated current: 22.0 A
Ijdpfxjinuhge Ag Usht
Rate of change: cooling approx. 3.5 K/min.
Rate of change: Heating approx. 4 K/min.
Temperature test
Temperature range -40°C to + 180°C
Display plan
External dimensions: W x D x H approx. 1390 x 2380 x 1995 mm
Test chamber dimensions: W x D x H approx. 1100 x 1475 x 950 mm
Weight approx. 1020 kg / 1540 liters
Refrigerant R 404A
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Temperature test chamber 1540 liters
VötschVT³ 4150 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4150
Vötsch Temperature Test Chamber, Air-Cooled
Temperature Testing
Temperature Range: -40°C to +180°C
Rate of Change: Cooling approx. 2.5 K/min
Rate of Change: Heating approx. 3.5 K/min
External Dimensions (W x D x H): approx. 1390 x 2380 x 1995 mm
Test Chamber Dimensions (W x D x H): approx. 1100 x 1475 x 950 mm
Rated Voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated Power: 11.5 kW
Rated Current: 22.0 A
Weight: approx. 1020 kg / 1540 liters
Refrigerant: R 404A
For your safety as a buyer, please note the following information:
We perform the following steps on all chambers offered:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: Used
Scope of delivery: (see photo)
(Technical data subject to change and errors excepted!)
Ijdpfx Ajw Ehutjg Ueht
For further questions, feel free to contact us by phone.
Listing
Borken
1,034 km
Climate test chamber 600 liters
WeissWK3-600/70 -70°C bis +180°C
Call
Condition: good (used), Weiss
Type: WK3-600/70
Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
Temperature change rate:
Heating: 4.0 K/min
Cooling: 2.5 K/min
Temperature deviation:
Over time: ±0.1 to ±0.5 K
Spatially: ±0.5 to ±1.5 K
Heat compensation max.: 2,500 W
Specifications for Climate Testing:
Temperature range: +10 to +95 °C
Dew point temperature range: -3 to +94°C
Humidity range: 10 to 98 % rH
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1 K
Humidity deviation over time: ±1 to ±3 % rH
Temperature uniformity (spatial): ±0.5 to ±1.0 K
Heat compensation max.: 500 W
Test chamber volume: 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1,998 mm, Width 1,000 mm, Depth 1,745 mm
Operating Data:
Isdsw Inmmspfx Ag Ujht
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19.0 A
Refrigerant: R404A & R23
Weight: 680 kg
Important information for you as the buyer:
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications subject to change. Errors and omissions excepted!)
If you have any further questions, we are happy to answer them by phone.
Listing
Borken
1,034 km
Temperature shock test chamber 60 liters
WeissTS 60 -72…+220 °C
Call
Condition: excellent (used), Weiss Technik TS 60 Thermal Shock Test Chamber / 60 L, –71…+220 °C
Iodpfsxr A R Tex Ag Ueht
Water-cooled
Item description:
For sale is a Weiss Technik TS 60 Thermal Shock Test Chamber.
The chamber is ideally suited for rapid temperature cycling tests (e.g., per IEC, MIL-STD, JEDEC) and has been well maintained.
Volume & internal dimensions:
Test volume: 60 liters
Internal basket/test room dimensions (W × D × H): approx. 380 × 430 × 370 mm
External dimensions (W × D × H): 895 × 1970 × 1895 mm
Temperature ranges & cycling:
Hot chamber: +50 °C to +220 °C
Cold chamber: –72 °C to +70 °C
Transfer time (basket between both zones): < 10 seconds
Heating rate / speed up to 17 °C/min
Cooling rate / speed up to 3.7 °C/min
In single mode (cold zone only), heating rate: approx. 3.2 °C/min
Temperature deviation & uniformity:
Temporal deviation (temperature control over time): ± 0.3 to ± 1.0 °C
Load / permissible weight & lifting system:
Basket/lifting system load capacity: 20 kg maximum load
Transfer basket secured by safety grilles on all sides
Additional features & equipment:
Noise level: approx. 58 dB(A) in operation
Control: Touchscreen, RS-232 / USB / Ethernet interfaces
Electrical connection:
3/N/PE AC 400 V ±10% 50 Hz
Rated power: approx. 8.5 kW
Rated current: approx. 25 A
On-site protection: 32 A
Refrigerants: R-404A / R-23
Weight: 800 kg
Important safety information for buyers!
The following steps are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors reserved!)
For further questions, feel free to contact us by phone.
We make it easier for you to find: "climatic chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Climatic Chamber (5,380)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month