English
German German German English English French French Spanish Spanish Italian Dutch Polish Russian Belarusian Ukrainian Estonian Turkish English English Czech Danish Finnish Swedish Norwegian Bokmål Maltese Luxembourgish Greek Lithuanian Latvian Icelandic Portuguese Portuguese Spanish Spanish Hungarian Slovak Romanian Romanian Slovenian Serbian Serbian Albanian Croatian Bulgarian Macedonian Bosnian Hebrew Arabic Hindi English Indonesian Korean Japanese Thai Malay Vietnamese Chinese Chinese Persian Bengali Pashto
Alfa Laval M10-BDFG Alfa Laval M10-BDFG Alfa Laval M10-BDFG Alfa Laval M10-BDFG Alfa Laval M10-BDFG Alfa Laval M10-BDFG
more images
6
Call
Riverside Trading Estate, Penketh, Warrington WA5 2UL, UK United Kingdom
370 km
new
New and Unused Alfa Laval M10-BDFG Heat Exchanger Vow3j7hh Please see photo of information plate for relevant details or contact us for further information
more images
4
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Heat exchanger of last use Gasket manufacture Type plate Odhpz Jacket volume Jacket volume 83 litres Jacket material AISI304 (V2A) 1.4301 Max. permissible operating overpressure Jacket volume 3.9 bar Max. permissible operating temperature Jacket volume 35 °C Pipe chamber volume Pipe chamber 140 litres Material pipes AISI304 (V2A) 1.4301 Max. permissible operating temperature Pipe chamber 150 °C Max. permissible operating pressure Pipe chamber 3.9 bar Techni...
Euro Barna de Calderia
more images
1
Call
Xcel Centre, Long Tens Way, Newton Aycliffe DL5 6AP, UK United Kingdom
455 km
2008
good (used)
Used Euro Barna de Calderia 18.4 square meter 316L stainless steel vertical shell and tube heat exchanger. Has (158) 19mm diameter X 2000mm long 316L stainless steel tubes rated 10 bar design pressure at 150°C. 406mm diameter X 2000mm high 316L stainless steel shell with expansion joint rated 6 bar design pressure at 50°C. 316L stainless steel heads, 6 pass design. Mounted on (2) lugs. Last used as sodium Percarbonate mother liquor cooler. New 2008. ** Process Equipment Ltd buys and sells high ...
EMAG MCW-100A-03MZ-3407 EMAG MCW-100A-03MZ-3407 EMAG MCW-100A-03MZ-3407 EMAG MCW-100A-03MZ-3407
more images
4
Call
Leipzig, Germany Germany
(dealership location)
1414 km
used
cooling capacity: 10 kW drive power: kW Fq3v2ur voltage: 400/460 V Number of ventilators: 2 (Ø 260mm) St. operating pressure: 25 bar total power requirement: 3,7 / 4,2 kw weight of the machine ca.: t dimensions L x W x H: m
APV A 055 APV A 055 APV A 055 APV A 055 APV A 055 APV A 055 APV A 055 APV A 055 APV A 055
more images
9
Call
Boxmeer Netherlands
979 km
2004
new
Details Brand APV Model: A 055 Year of manufacture: Unused, 2004 Serial Number: 62988 2tjmi3 Dimensions LxWxH (mm) 1000 x 800 x 1700 Weight (Kg) approx 800 Max. working pressure (Bar) 6 Made in Denmark Comments Heating surface 40,2 m2, Working pressure 6 bar, test pressure 9 bar, volume side1: 65,7 ltrs, volume side 2: 65,7 ltrs, working temerature max. 100 degrees celcius Price on request
Sanyo SGP-WE170J2 50kw Sanyo SGP-WE170J2 50kw Sanyo SGP-WE170J2 50kw Sanyo SGP-WE170J2 50kw Sanyo SGP-WE170J2 50kw Sanyo SGP-WE170J2 50kw Sanyo SGP-WE170J2 50kw Sanyo SGP-WE170J2 50kw
more images
8
SANYO Water Heat Exchanger Model: SGP-WE170J2 Power source: 220-240 V AC, 1 phase, 50 Hz Maximum electrical power: 9 kW, 0.05 A (continuous operation) Device protection: IP24 Cooling capacity: 50 kW Heating power: 60 kW Heat input (HS) (cooling): 43.5 kW Heat input (HS) (heating): 46 kW Refrigerant: R407C Design pressure high pressure side: 30 bar Design pressure low pressure side: 16 bar Purchase, Acquisition, asset management of industrial equipment and machinery. Bfumh3aadt Wide Range of Us...
QVF HEC600/150
more images
1
Call
Riverside Trading Estate, Penketh, Warrington WA5 2UL, UK United Kingdom
370 km
excellent (used)
Pre-owned but in excellent condition. This is a QVF HEC600/150 glass coil heat exchanger. We currently have 3 in stock Details: Blky28eyqc Heat Transfer Area - 15m² Height - 1250mm Diameter - 600mm Ports for inlet and outlet are 50mm
more images
8
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Miscellaneous formerly melting condenser; Outer chamber I: capacity: 420 litres, permissible operating overpressure: -1/+6 bar; permissible operating temperature: 200° C; Outer chamber II: capacity: 66 litres, permissible operating overpressure: -1/+3.2 bar (was reduced from 6 to 3.2 bar by the previous operator); permissible operating temperature: 200° C Heat exchanger Technical documentation Drawing,TÜV papers Exchange surface 21.0 m² Last use Chemistry N...
APV APV APV
more images
3
Call
Xcel Centre, Long Tens Way, Newton Aycliffe DL5 6AP, UK United Kingdom
455 km
good condition (used)
Used APV approximately 50.4 square meter stainless steel shell and tube bundle heat exchanger. Has (328) 16mm diameter X 3060mm long stainless steel tubes rated 3 bar pressure. Stainless steel shell measures approximately 700mm diameter X 3060mm long rated 1.5 bar pressure. Bolted stainless steel heads. Couwfyn3 ** Process Equipment Ltd buys and sells high quality used and refurbished process equipment worldwide. We have equipment in stock, immediately available, and can save you considerabl...
KÜMA APPARATEBAU GMBH RWT30-1KK KÜMA APPARATEBAU GMBH RWT30-1KK KÜMA APPARATEBAU GMBH RWT30-1KK KÜMA APPARATEBAU GMBH RWT30-1KK KÜMA APPARATEBAU GMBH RWT30-1KK KÜMA APPARATEBAU GMBH RWT30-1KK
more images
6
Call
Leipzig, Germany Germany
(dealership location)
1414 km
2003
used
operating pressure: 10 bar voltage: 400/50 V/Hz Tpsv9tou0 control voltage: 24 V total power requirement: 0,76 kw weight of the machine approx.: 160 kg space requirements of the machine approx.: 0,58x0,68x1,35 m heat exchanger application area: transportation of heat energy from a medium to another medium (liquid or gas) connections 3/4" for flow/return 2x both sides 2 Pieces available
Jäggi R29-W5 Jäggi R29-W5 Jäggi R29-W5 Jäggi R29-W5 Jäggi R29-W5 Jäggi R29-W5
more images
6
Call
Grenzach-Wyhlen Germany
1301 km
1989
ready for operation (used)
Jäggi R29-W5 stainless steel tube bundle heat exchanger Fb9383p This heat exchanger was expanded by our company and was in working condition before dismantling. Ask for the details. The price is ex works Grenzach. Visit us at permasale(.)de, here you will find our current complete stock programme.
SPIRAX SARCO unbekannt
more images
1
Call
Ulm Germany
1391 km
1997
good (used)
Jacket and pipes made of 1.4571 Power 600 kW Cjezttqo 7,400 litres of water from 10 °C to 80 °C at 8 bar saturated steam and 90 °C condensate temperature
Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher Funke Apparatebau GmbH  18m²  V4A 1.4541 U-Rohr Tauscher
more images
10
Tube bundle heat exchanger in U-tube design with 4-way flow. Pressure test was carried out All TÜV protocols/drawings available Material tube/jacket: 1.4541 Gxr22jej Tube dimension: 10x1mm Exchanger surface: 18m² max. overpressure jacket: 10 bar max. overpressure tube: 10 bar max. temperature: 200°C capacity shell side: 50 litres capacity pipe side: 29 litres connection jacket side: 3" max. flow rate jacket: 80m³/h connection pipe side: 1" max. flow rate pipe: 8-10m³ weight: approx. 200kg Overal...
more images
5
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Other inside:Pressure: 23 barTemperature: 150°CContent: 8,3 Literoutside:Pressure: 12 barTemperature: 190°CContent: 18.5 Liter Remarks Dents in Isomantel Heat exchanger last use Dairy prehead 2 preheads missing Year of construction 2012 Insulation available Material insulation jacket stainless steel Shell chamber material shell AISI316 (V4A) 1.4404 Bwxx0ypcaf
Atlas Copco Atlas Copco Atlas Copco Atlas Copco
more images
4
Office heating, compressor, Atlas Copco ER S-3 heat exchanger APC10 0083 Gl3oecsom Year of production 2010 Product code: 8475
more images
6
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Other 8 minutes hot holdingPipes DN 80Length: 647 metersManufacturer: Tetra PakWeight approx. 7 t Remarks 6 height-adjustable feet; minor dents in the insulating jacket; insulating jacket is no longer present in 2 sections (see photos) Heat exchanger last use dairy insulation available material insulation jacket stainless steel Tube chamber material tubes AISI304 (V2A) 1.4301 Technical data / dimensions Total height 3,200 mm Total width 1,550 mm Total lengt...
more images
6
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Miscellaneous Adhesions inside the steam pipe Heat exchanger Technical documents Drawing,TÜV papers Last use Chemistry Type plate Year of construction 2006 Bi8bleghqw Shell space Volume shell space 165 litres Material shell AISI304 (V2A) 1.4541 Max. permissible operating overpressure shell space 13,0 bar Max. permissible operating temperature shell space 300 °C Pipe space Volume of pipe space 350 litres Material of pipes AISI316 (V4A) 1.4571 Number of pipes...
more images
4
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Heat exchanger of last use Food colouring Nameplate Jacket volume Jacket volume 289 litres Jacket material AISI304 (V2A) 1.4301 Max. permissible operating overpressure Jacket volume 6.0 bar Max. permissible operating temperature Jacket volume 20 °C Pipe chamber volume Pipe chamber 60 litres Material pipes AISI304 (V2A) 1.4301 Max. permissible operating temperature Pipe chamber 150 °C Technical data / dimensions Inner diameter 500 mm Total length 2,650 mm Cr...
more images
15
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition unused Heat exchanger Technical documents Drawing Exchange surface 4,0 m² Last use Pharmacy Type plate Year of construction 2002 Insulation available Material insulation jacket Stainless steel Stsiqo Shell space Volume shell space 9 litres Material shell AISI316 (V4A) 1.4571 Max. permissible operating overpressure shell space 10,0 bar Max. permissible operating underpressure shell space 1,0 bar Max. permissible operating temperature shell space 50 °C Pipe chambe...
more images
2
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General condition used Heat exchanger last application Pharmacy Name plate Material insulating jacket Stainless steel Jacket volume Jacket volume 4 litres Jacket material AISI316 (V4A) 1.4571 Max. permissible operating temperature Jacket volume 100 °C Pipe chamber volume Pipe chamber 3 litres Material pipes AISI316 (V4A) 1.4435 Max. permissible operating temperature Pipe chamber 100 °C Max. permissible operating pressure Pipe chamber 11.0 bar Lzeixmr Technical data / dimensions Total length 2,65...
more images
9
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Remarks Shell made of heat-resistant structural steel: permissible operating overpressure: 72 bar; permissible operating temperature: 300° C; capacity: 400 litres; tubes made of titanium II: permissible operating overpressure: 200 bar; permissible operating temperature: 300°C; capacity: 100 litres L3dupu2 Heat exchanger Technical documents Drawing,Acceptance certificate last Intended use Chemistry Technical data / dimensions Total length 8.512 mm
more images
3
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General condition used Remarks 1 x prehead gasket defective heat exchanger technical documents drawing exchange surface 2,0 m² last use pharmacy year of construction 2000 insulation available material insulation jacket stainless steel insulation material mineral wool Shell space Volume shell space 27 litres Material shell AISI316 (V4A) 1.4571 Max. permissible operating overpressure shell space 6,0 bar Max. permissible operating temperature shell space 140 °C Pipe chamber Volume of pipe chamber 5...
more images
3
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General condition used Heat exchanger exchange surface 1,65 m² last application pharmacy type plate insulation existing material insulation jacket stainless steel Jacket volume Jacket volume 4 litres Jacket material AISI316 (V4A) 1.4571 Max. permissible operating overpressure Jacket volume 10.0 bar Max. permissible operating temperature Pipe chamber volume Pipe chamber 3 litres Material pipes AISI316 (V4A) 1.4571 Number of pipes 22 Max. permissible operating temperature Pipe chamber 160 °C Max. ...
more images
5
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Remarks Room 1: Capacity: 15 liters; max. operating pressure: -1 bar; max. operating temperature: 150°C; Room 2: Capacity: 4 liters; max. operating pressure: 5 bar; max. operating temperature: 50°C; front heads made of Fe, pipes made of stainless steel Heat exchanger of last use Food colouring Nameplate L20dka0 Jacket chamber Material jacket AISI316 (V4A) 1.4571 Technical data / dimensions Diameter inside 140 mm Total length 1,500 mm
more images
5
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Miscellaneous Flanges partly made of mild steel Heat exchanger Technical documents Drawing,TÜV papers Exchange area 39,0 m² Last use Reflux cooler in a glue production Type plate Shell space Volume shell space 300 litres Material shell AISI304 (V2A) 1.4301 Max. permissible operating overpressure shell space 6,0 bar Max. permissible operating temperature shell space 80 °C Pipe chamber Volume of pipe chamber 410 litres Material of pipes AISI304 (V2A) 1.4541 N...
more images
3
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General condition used Remarks outside polished; possibly unused Heat exchanger Technical documents Drawing Exchange surface 2,12 m² Last use Distillate cooler (1000 l/h; Pharmacy) Type plate Year of construction 2006 Insulation available Material insulation jacket Stainless steel Er3nbmras Shell space Volume of shell space 27 litres Material of shell AISI316 (V4A) 1.4404 Max. permissible operating overpressure of shell space 8.0 bar Max. permissible operating temperature of shell space 100 °C P...
more images
6
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Manufacturer GEA Location Bremen Condition used Bvqgzvogln
more images
4
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Heat exchanger Technical documents Drawing,TÜV papers Exchange area 8.5 m² Last use chemistry Type plate insulation available Material insulation jacket steel Shell space Volume shell space 97 litres Material shell AISI316 (V4A) 1.4571 Max. permissible operating overpressure shell space 8,0 bar Max. permissible operating underpressure shell space 1,0 bar Max. permissible operating temperature shell space 200 °C Pipe space Volume of pipe space 53 litres Mate...
more images
9
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Miscellaneous Differences in the design of the heat exchangers; flanges partly made of mild steel; isosleeves with minor damage (see photos). O0ejp heat exchanger last use dairy insulation available
more images
5
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Heat exchanger last use brewery nameplate year 1987 Insulation available Material insulation jacket stainless steel Jacket volume Jacket volume 44.8 litres Max. perm. operating overpressure Jacket volume 3.0 bar Max. perm. operating temperature Jacket volume 142 °C Pipe chamber volume Pipe chamber 33.3 litres Max. permissible operating temperature Pipe chamber 142 °C Max. permissible operating overpressure Pipe chamber 3.0 bar B3gr9smq
more images
4
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Heat exchanger exchange surface 8.5 m² last use brewery type plate year 1984 insulation existing material insulation jacket stainless steel Bkw2imbfit Jacket volume Jacket volume 54 litres Max. perm. operating overpressure Jacket volume 15.0 bar Max. perm. operating temperature Jacket volume 170 °C Pipe chamber volume Pipe chamber 22 litres Max. permissible operating temperature Pipe chamber 170 °C Max. permissible operating overpressure Pipe chamber 4.0 ba...
more images
10
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Remarks A heat exchanger has no type plate. The recoolers have different connections. Bkw2fwgsuk Heat exchanger exchange surface 4.8 m² Type plate Year of construction 1995 Insulation available Jacket volume Jacket volume 210 litres Pipe chamber volume Pipe chamber 60 litres
more images
5
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Remarks Front head from 1.4571 (V4A); smaller dents in the iso-mantle Heat exchanger exchange surface 7.7 m² last use brewery type plate insulation existing insulation material insulation jacket stainless steel Jacket volume Jacket volume 55 litres Max. perm. operating overpressure Jacket volume 5.0 bar Max. perm. operating temperature Jacket volume 170 °C Pipe chamber volume Pipe chamber 48 litres Max. permissible operating temperature Pipe chamber 99 °C M...
more images
3
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Others Front head from 1.4571 (V4A); smaller dents in the iso-mantle Heat exchanger last use brewery nameplate year 1987 Insulation available Material insulation jacket stainless steel Pumo3e Jacket volume Jacket volume 44.8 litres Max. perm. operating overpressure Jacket volume 3.0 bar Max. perm. operating temperature Jacket volume 142 °C Pipe chamber volume Pipe chamber 33.3 litres Max. permissible operating temperature Pipe chamber 142 °C Max. permissibl...
more images
6
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used 3cj9bjyh Heat exchanger type plate year of construction 2002 Insulation available Jacket volume Jacket volume 216 litres Max. permissible operating temperature Jacket volume 80 °C Pipe chamber volume Pipe chamber 1,000 litres Max. permissible operating temperature Pipe chamber 80 °C
more images
7
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Others Front head from 1.4571 (V4A); smaller dents in the iso-mantle Bkw2jiuwew Heat exchanger exchange surface 10,0 m² last application brewery type plate insulation existing material insulation jacket stainless steel Jacket volume Jacket volume 75 litres Max. perm. operating overpressure Jacket volume 6.0 bar Max. perm. operating temperature Jacket volume 200 °C Pipe chamber volume Pipe chamber 61 litres Max. permissible operating temperature Pipe chamber...
more images
3
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Remarks Front head from 1.4571 (V4A); smaller dents in the iso-mantle Bkw2damaab Heat exchanger exchange surface 4.7 m² last use brewery type plate insulation existing insulation material insulation jacket stainless steel insulation material mineral wool Jacket volume Jacket volume 34 litres Max. permissible operating overpressure Jacket volume 5.0 bar Max. permissible operating temperature Jacket volume 170 °C Pipe chamber volume Pipe chamber 30 litres Max...
more images
4
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Miscellaneous Insulation in parts no longer present (see photos); insulation jacket with dents and sheet metal cuts; feet cut off at bottom (see photos) Ewczs3xt Heat exchanger Technical documents Drawing Exchange surface 16,0 m² Last use Pharmaceutical chemistry Type plate Insulation available Material Insulation jacket Aluminum Shell space Volume of shell space 202 litres Material of shell AISI304 (V2A) 1.4306 Max. permissible operating overpressure of sh...
more images
3
Call
Bremen, Germany Germany
(dealership location)
1145 km
ready for operation (used)
General Location Bremen Condition used Miscellaneous The outer diameter is somewhat larger in one section (presumably prehead flange) with approx. 740 mm; insulation jacket with dents and sheet metal cuts Heat exchanger Exchange area 16,0 m² Last use Pharmaceutical chemistry Type plate Insulation available Material Insulation jacket Aluminium Shell space Volume of shell space 202 litres Material of shell AISI304 (V2A) 1.4306 Max. permissible operating overpressure of shell space 16.0 bar Max. pe...
 

Used Heat exchangers

Completely search Machineseeker and more than 200,000 used machines now.
This may be of interest to you

Machineseeker still biggest sponsors of 2nd German football league

Morlock Motors official partner of Machineseeker and Truckscout24

How to receive 100% of our e-mails

Olympic Games: Machineseeker sponsors Team Germany

Photo gallery: the 10 strongest forklift trucks in the world

Sample sales contract for used machines in nine languages

Machineseeker.ie is official sponsor of:
FEEDBACK
Successful: Task carried out
Error: Task could not be carried out
Flag gb
+44 20 331 800 72
Flag de
+49 201 857 86 10
Flag nl
+49 201 857 86 180
Flag pl
+48 223 076 958
Flag it
+49 201 857 86 152
Flag es
+34 911 433 456
Flag fr
+49 201 857 86 153