Used Voetsch for sale (107)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Vötsch
Listing

450 km
Microwave Oven
VötschMicrowave Oven
Call
Year of construction: 2012, operating hours: 75 h, condition: like new (used), This Vötsch Hephaistos Industrial Microwave Chamber has had extremely low hours usage during its life so far, on 75 hours .. having been installed and minimally utilized from time to time for a single research project at the University of Sheffield AMRC research department known as the “Factory of the Future”. Sold new for a price of approx 250,000.00Euro. Contact us now for an exceptional offer for this high tech unit in as new condition.
Gsdpfxetvz Rfe Aacouh
VHM Hephaistos Industrial Microwave Chamber For Aerospace and Automotive Engineering
The Research Project
The VHM Hephaistos Industrial Microwave Chamber for component testing was developed in cooperation with the Karlsruhe Institute of Technology (KIT). It is the result of a joint development project sponsored by the German Federal Ministry of Education and Research (BMBF). Alongside KIT, the Composite Research Center of EADS in Munich, the Institute for Aircraft Design (IFB) at the University of Stuttgart, GNK Aerospace in Munich and Vötsch Industrietechnik were involved in the project.
Microwave system
The VHM Hephaistos Industrial Microwave Chamber from Vötschtechnik is an internationally patented system. Fast and energy-efficient production processes are possible by using microwaves. The microwave chamber is characterized by its hexagonal geometry with a very high field homogeneity. This is a major advantage when thermoforming fibre composites (CFRPs) in the aerospace and automotive industries.
During the targeted volumetric heating of the products, the microwaves directly enter the material so that energy is delivered directly and the chamber does not require heating. This increases the heating rate and throughput, saving energy and time in addition.
Reduced production costs
This industrial microwave chamber guarantees you reduced costs due to shorter heating, process and cooling times required for curing CFRP components. Its material processing technology means the microwave can produce energy input into the component to be heated while the oven itself remains cold. In comparison to the process in autoclaves, the processing times are reduced by up to 50 %. Energy consumptions is reduced by up to 70%.
Advantages:
Possibility to use metal parts, such as conventional metal tools and feed systems, in the microwave field
High degree of product quality thanks to the maximum homogeneity of the microwave fields provided by the hexagonal chamber structure. By using microwave absorbing materials, additional positive effects can be achieved
Sizes from laboratory scale to large systems, e.g. as are required in the aerospace industry, can be achieved
The modular design allows a flexible adjustment to your product
Volumetric and selective heating for energy-efficient processes
Precise heating of the products
Hybrid systems, e.g. in combination with hot air
Listing

1,034 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Gedpfx Aaoxmhycoceuh
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing

941 km
VÖTSCH climatic test chamber
Vötsch
Call
Year of construction: 2019, condition: good (used), Various climate chambers for testing a wide range of products.
Example:
Vötsch
Type: VC 0018
Climate test chamber
Gusdpfxjxgrz Rs Aacoh
Air-cooled
Test chamber dimensions: Width 580 x Depth 450 x Height 750 mm

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing

987 km
Heating and drying cabinet
VötschVTU 100/150
Call
Year of construction: 2017, condition: good (used), functionality: fully functional, Heating cabinet / Drying cabinet
Vötsch VTU 100/150
* Nominal temperature: 250 °C
* Internal usable volume: 1.5 m³
Guodpfjxg Rhiox Aacjh
* Internal dimensions:
Width: 1000 mm
Height: 1500 mm
Depth: 1000 mm
Listing

1,316 km
Paint dryer DIN 1539 300°C
VötschVTL 100/150 nach DIN 1539
Call
Year of construction: 2001, condition: refurbished (used), functionality: fully functional, with safety system for solvent-based substances according to DIN 1539, including exhaust air fan, supply air cage filter, as well as concentration monitoring and recirculation filter wall in the interior
Completely overhauled, 12 months warranty
-Internal dimensions (WxDxH): 1000 x 1000 x 1500 mm
-External dimensions (WxDxH): 1900 x 1430 x 2315 mm
-Volume: 1500 liters
-Max. temperature: 300°C
-Eurotherm Controller 2404 (20 programs, each with 16 segments)
-Eurotherm data recorder
-Connected load: 29 kW
-6 mesh shelves included, as well as V2A support brackets
-Minimum exhaust air volume flow: 360 m³/h
-Maximum permissible solvent quantity: 36 g at nominal temperature of 300°C
-with concentration measurement
-Window seals renewed
-Approximate net weight: 1200 kg
-Including documentation, CE Declaration of Conformity
Viewing possible by appointment in our warehouse.
Godpovcb U Ajfx Aacsuh
We supply new and used industrial furnaces. Contact us!
Oven, drying oven, kiln, heat oven, heating cabinet, industrial oven, paint dryer, tempering oven, heating oven, annealing oven, temperature oven, drying cabinet, chamber oven, curing oven, recirculating air drying cabinet, recirculating air oven, solvent oven
Discover more used machines
Listing

1,324 km
Emissions test chamber
VötschVCE 200
Call
Condition: used, Description: Emission Test Chamber
Manufacturer: Vötsch
Model: VCE 200
Test chamber volume: 200 liters
Temperature range: +20°C to +130°C
Humidity range: 30 to 95% RH
Temperature deviation: temporal ± 0.3 K
Temperature deviation: spatial ± 0.5 K
Average temperature change rate: cooling approx. 0.3 K/min, heating approx. 0.4 K/min
Dew point range: +5°C to 60°C
Humidity deviation: temporal ± 1 to 3% RH
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power / rated current: 21 kW / 41 A
Refrigerant: R404A
Internal test chamber dimensions: 610 x 610 x 560 mm (W/D/H)
Overall dimensions: 1250 x 1700 x 2350 mm (W/D/H)
Weight: approx. 750 kg
Item Condition:
Godjxg Hrqjpfx Aacjuh
Used item as shown in the pictures
Please contact us if you have any questions
Shipping:
The quoted shipping costs apply to deliveries within Germany
Worldwide shipping available (please inquire for shipping costs outside Germany)
The given shipping costs apply to shipping within Germany
Sale exclusively to business customers, without warranty or guarantee.
Deviations from technical data and errors in the item description may occur and are reserved.
Listing

1,027 km
Air-cooled climatic test chamber
VötschVC 0033
Call
Condition: good (used), Climatic Test Chamber +10°C to +90°C, Air-Cooled
The test chamber is designed and built for climatic testing within its operating range.
Test procedures that determine the influence of temperature and humidity on material properties
and functional reliability of the test specimen can be performed.
The test chamber can be operated in manual mode (fixed-value mode) or automatic mode.
The EDIT program can be used to program extensive climatic tests and save a maximum of 99 test programs.
These test programs are run in automatic mode.
Godexbnkwjpfx Aacsuh
The test chamber can be controlled during operation via the RS 232 interface with a computer and the TSI software or in ASCII mode.
The operating temperature limiter protects the test specimen from excessively high temperatures.
To protect the test specimen, the upper and lower temperature limits can also be set on the terminal.
Manufacturer: Heraeus Vötsch
Type: VC 0033
Specifications for temperature tests:
Temperature range: +10°C to +90°C
Humidity range: 30 - 95%
Rated voltage: 230V +6/-10% 1/N 50Hz
Rated power: 2.7 kW
Rated current: 12 A
Refrigerant: R 404A
Test chamber volume: approx. 333 liters
Humidity range:
Humidity range for normal operation (ranges 1 and 3) with a dew point limitation of +5°C
Humidity range 3 is omitted if additionally equipped with a capacitive humidity measurement system
Tolerances for standard climate conditions
23°C/65% RH
Temperature ±0.1 K
Humidity < ±1.5%
85°C / 85% RH
Temperature ±0.1 K
Humidity
Listing

1,034 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test chamber volume: 335 litres
Performance for temperature testing:
Temperature range: -70 to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Performance for climate testing:
Temperature range: +10 to +95°C
Temporal temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Temporal humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50 % RH and +95°C / 50 % RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10%, 50 Hz
Nominal power: 10 kW
Nominal current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R-404A / R-23
For your safety as a buyer, please note the following information!
The following steps are carried out on all our offered chambers in advance:
Guodpfx Aaexgd Rdocoh
1. Functional check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors reserved!)
Feel free to contact us by phone for any further questions.
Listing

1,332 km
Drying system
Vötsch Industrietechnik Vakuum TrocknerVHT 125/170 WW Vacuum Tray Dryer 2.47 m3
Call
Condition: used, Year of construction: 1998, functionality: fully functional, 2 pieces vacuum drying oven GMP-compliant, Vötsch Industrietechnik (can also be sold individually). Material product-touched stainless steel 1.4435. Type of heating, externally heated hollow inserts, the ceiling is also heated, double-shelled with meander baffles inside, pressure-tight up to 3 bar. Heating via heating/cooling circuit (indirect heating using hot water) via separate DHW thermistats.
Operating temperature max. 95°C, operating pressure inside tank 0 to 1 bar abs.
External dimensions: 1485 mm width (housing), 2000 mm height (housing), 1700 mm depth
Insert trays: 1200 mm width x 950 mm depth
Number of shelves: 13 pieces
Covered area: 14.8 m2
Weight approx. 2900 kg per dryer
Connections: Hot water connection (flow and return) Vacuum connection
Gsdpfx Aajucdqnoceuh
Heating of the vacuum drying ovens by means of a heating medium, e.g. water, connections at the rear. Heating of the heating medium by means of temperature control unit with control type 95-36-E Nominal voltage 400 V 3/N PE AC, 50 Hz, heating capacity of the unit 36 kW, heating capacity can be reduced to 18 kW in a definable temperature range.
Listing

1,316 km
Electric convection oven 300°C
VötschVTU 100/150
Call
Year of construction: 2001, condition: refurbished (used), functionality: fully functional, Overhauled and electrically tested, 12-month warranty
- Max temperature: 300°C
- Internal dimensions: W 1000 x D 1000 x H 1500 mm
- External dimensions: W 1765 x D 1425 x H 2300 mm
- Jumo Dicon 1001, 25 programs with 100 segments each
- No loading rails (see picture)
- Small platform trolley available on request
- Connected load: 29 kW
Gsdpfxov E Iwco Aaceuh
- Net weight: approx. 750 kg
- Documentation included
Inspection possible by appointment in our warehouse.
Oven, ovens, drying oven, kiln, heat oven, heating cabinet, industrial oven,
tempering oven, heating oven, tempering oven, drying cabinet, chamber oven, baking oven, circulating air drying cabinet, circulating air oven, tempering oven
Listing

1,027 km
Drying cabinet Chamber oven
VötschVTU 100/150
Call
Condition: good (used), Vötsch VTU 100/150 heating and drying cabinet
Manufacturer: Vötsch
Type: VTU 100/150
Nominal temperature: 250 °C
Usable volume: 1500 m³
Total load: 400 kg
Nominal power: 27 kW
Connected load: 29 kW
Nominal current: 42 A
Mains connection: 400 V, 3 PH+N PE, 50 Hz
Weight: 780 kg
Microprocessor-controlled temperature and program controller
Jumo two-point controller
Godpexbgt Dofx Aaceuh
Digital display of setpoint/actual temperature, plain text display
Easy loading of the device floor via folding ramp
Dimensions
Interior: (W x H x D) 1000 x 1500 x 1000 mm
External: (W x H x D) 1840 x 2389 x 1450 mm
You can find more items—new and used—in our shop!
International shipping costs on request!
Listing

1,034 km
Climatic chamber with humidity, 335 liters
VötschVC³ 7034 -70°C bis +180°C
Call
Condition: excellent (used), Type: VC³ 7034
Heraeus Vötsch Climate Test Chamber with Humidity Control (Air-Cooled)
Test Chamber Dimensions: Width 580 mm x Depth 765 mm x Height 750 mm
External Dimensions: Width 780 mm x Depth 1,758 mm x Height 1,800 mm
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
Temporal deviation: ± 0.1 to ± 0.5 K
Spatial deviation: ± 0.5 to ± 1.5 K
Temperature change rate according to IEC 60068-3-5
Heating: 3.0 K/min
Cooling: 3.0 K/min
Specifications for Climate Testing:
Temperature range: -70°C to +180°C
Temperature deviation in steady-state condition, according to IEC 60068-3-5
(depending on chamber temperature)
Temporal deviation: ± 0.1 to ± 0.3 K
Spatial deviation: ± 0.5 to ± 1 K
Humidity range: 10% to 98% RH
Godpfexfh Spex Aacjuh
Electrical Connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 4.9 kW
Rated current: 16 A
Protection: 16 A slow-blow fuse, provided by customer
Refrigerant: R-404A/R23
Test chamber volume: approx. 335 liters
Net weight: approx. 515 kg
For your safety as a buyer, please note the following information:
The following actions are performed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, chambers undergo a documented test run.
Condition: Used
Scope of delivery: (see picture)
(Subject to modifications and errors in technical data and specifications!)
For further inquiries, please feel free to contact us by phone.
Listing

1,027 km
Large-scale climate test chamber
VötschVCZ 04032
Call
Condition: good (used), Large-scale system for climate tests with S!MCON control
Design
The system consists of the following main components:
- Walk-in, insulated test room
- Air treatment room
- Machine unit
- Air conditioning system
- Control cabinet
Test room
The fixtures in the test room are made of corrosion-resistant material.
The test room can be illuminated, is walk-in, and has a condensate and cleaning drain.
Air treatment room
The air treatment room is located behind the air baffle in the insulated interior.
It contains the following components necessary for temperature control and is accessible via easily removable panels.
- Test room fans
- Heat exchangers
- Electric heaters
- Ventilation and exhaust system
- Temperature sensors
In the air treatment room, the air is tempered (cooled/heated), humidified and dehumidified, and circulated by fans.
The air is drawn in under the ceiling and expelled at floor level.
Sensors
The temperature and humidity sensors are located behind the air baffle in the air treatment room.
Machine Unit
The machine unit, consisting of refrigeration units, supplies the air treatment room with the required energy.
Climate System
The climate system consists of:
- Steam humidifier
- Dehumidification evaporator
Technical Data
Test chamber volume: approx. 32 m³
Direct temperature range: -40 to +100°C
Godpew U Sv Eefx Aacouh
Temperature fluctuation over time in the center of the usable space: +/- 0.5 to +/- 1
Temperature change rate
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min
Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% RH
Dew point range: 5 to 93°C
Temperature fluctuation: +/- 5°C
Humidity fluctuation: +/- 3 to +/- 5% RH
Cooling water specifications
Connections
Inlet: 2 x 1 1/2" RH
Return: 2 x 1 1/2" RH
Consumption at full load: max. 16 m³/h
Maximum load on the test chamber floor: 10,000 N/m²
Nominal voltage: 3/N / PE AC 400 V 50 Hz
Nominal power: 97 kW
Nominal current: 148 A
Dimensions:
Test chamber: Width 3.60 m, Height 2.20 m, Depth 5 m
Climate chamber divided for transport at a specified location (approx. 2.50 m).
Find more items – new and used – in our shop!
International shipping costs on request!
Listing

1,034 km
Climate test chamber 335 liters with humidity
VötschVC 4034 -40°C..+180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Godpsxbrkhefx Aacouh
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,034 km
Assembly test cabinet -30°C to +100°C
VötschVT 3050-M
Call
Condition: excellent (used), Vötsch
Type: VT 3050-M
Vötsch Subassembly Test Chamber Lifetimetester, Air-cooled
Vötsch VT 3050-M Temperature Test Chamber / Climatic Chamber 500 Liters
For sale is a used Vötsch VT 3050-M temperature test chamber (500 L internal volume).
It is ideally suited for temperature tests in research, development, industry, or quality assurance.
Godpjxbrffjfx Aacjuh
Features:
- Durable stainless steel interior
- 1 shelf included
- Cable port (Ø 80 mm)
- Interior lighting
- Mobile on casters
- Safety functions (thermal limiter, etc.)
Technical data:
Manufacturer: Vötsch
Model: VT 3050-M
Internal volume: 500 L
Temperature range: –30 °C to +100 °C
Internal dimensions (W × D × H): approx. 710 × 590 × 1250 mm
External dimensions (W × D × H): approx. 940 × 1030 × 1955 mm
Heating/cooling rates: approx. 2 K/min (heating), 1.4 K/min (cooling)
Max. heat compensation: 650 W
Control: modern touchscreen panel (multi-language), Ethernet port
Power supply: 1/N/PE AC 230V+10% 50Hz
Rated power: 2 kW
Rated current: 12 A
Refrigerant: R-404A
Weight: approx. 350 kg
Important buyer information for your safety:
The following procedures are carried out on all chambers offered by us prior to sale:
1. Functional inspection and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, a documented trial run of the chambers is performed.
Condition: used
Scope of delivery: (see picture)
(Specifications may be subject to change and errors!)
If you have further questions, we are happy to answer them by phone.
Listing

1,034 km
Temperature test chamber 600 liters
VötschVTV 7060-5 -70°C bis +180°C
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTV 7060-5
Vibration and More ...
... Dynamic and Climatic Reliability Testing
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
(with chamber feed-through for shaker for vibration testing)
Easily test tall samples
With the electrically adjustable height of the test chamber, you can easily test even extra-tall test specimens.
Gsdpfxsxbgcre Aacsuh
On-site adaptation to the final shaker height is possible.
Standard features, perfect down to the last detail:
- Operating terminal with color touch panel
- Microprocessor monitoring and control S!MCON/32*-NET
- Digital I/O, potential-free
- Independent, adjustable temperature limiter tmin/tmax
- Adjustable software temperature limiter min./max.
- Serial interface RS 232
- Volt-free contact for specimen deactivation
- Water-cooled refrigeration unit
- Calibration at 2 temperature points
- Removable chamber floor with feed-through
- 2 pipe ports Ø 50 mm and Ø 125 mm
Vötsch Temperature Test Chamber VTV 7060-5
Test chamber volume: 600 liters
Temperature Testing Performance:
Temperature range: -70/+180 °C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Temperature change rate, heating: 6.0 K/min
Temperature change rate, cooling: 6.0 K/min
Heat compensation at +20 °C: 5000 W
Heat compensation at -20 °C: 5000 W
Test chamber dimensions: Width 800 mm, Depth 800 mm, Height 950 mm
External dimensions: Width 1225 mm, Depth 2890 mm, Height 2150 mm
Height to lower edge of chamber floor min/max: 660/1380 mm
Feed-through for vibration system: 710 mm Ø
Feed-through for vibration system: 700/700 mm
Electrical connection: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 14 kW
Rated current: 26 A
Sound pressure level - 1 m in front: 75 dB(A)
Refrigerant: R-404A / R-23
Weight approx. 650 kg
Important information for your peace of mind as a buyer!
The following points are carried out on our offered chambers before delivery:
1. Function check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Delivery scope: (see picture)
(Specifications and subject to change, errors and omissions excepted!)
For further questions, we are happy to answer your queries by phone.
Listing

1,034 km
Headlight test bench
Weiss / Vötsch VCS³ 4100-5-S(Indoor & Outdoor) Scheinwerferprüfstand
Call
Condition: excellent (used), Vötsch
"Headlight Test Bench – Weiss/Vötsch VCS³ 4100-5-S (Indoor & Outdoor), available from calendar week 40"
Year of manufacture: 2018
For sale is a complete temperature and climate testing system for front headlights, consisting of two coupled Vötsch VCS³ 4100-5-S climate test chambers (indoor & outdoor versions). The system was specially developed for the automotive industry and enables combined environmental testing to OEM standards.
Main Features
- Temperature and climate testing
- Rain/spray simulation (flow rate 1–18 l/min, spray temperature 5–32 °C, 200 l tank)
- Infrared irradiation (4 × 1.2 kW) for solar load simulation
- Vacuum unit (0–50 Pa) for leak testing
- Airflow up to 15 m/s (driving wind simulation)
- Real-time webcam monitoring
- Comprehensive sensor suite (temperature and humidity sensors)
- Additional power supplies for test specimens (12–48 V)
Outdoor chamber (VCS³ 4100-5-S Outdoor):
- Temperature range: –20 … +80 °C
- Heating rate: 5 K/min | Cooling rate: 3 K/min
- Humidity range: 4 … 95% rH
- Dew point range: –30 … +79 °C
- Extras: webcam, 5 temperature sensors
Indoor chamber (VCS³ 4100-5-S Indoor):
- Temperature range: –20 … +125 °C
- Heating rate: 8 K/min | Cooling rate: 5 K/min
- Humidity range: 4 … 95% rH
- Dew point range: –30 … +88 °C
- Vacuum unit: 0 … 50 Pa
- Airflow: 0 … 15 m/s
- Extras: 4 power supplies (12–48 V), 3 temperature sensors, 2 humidity sensors
Application areas
Ideal for testing headlights and similar components under real-world conditions. Suitable for use in automotive development, quality assurance, approval tests, and durability testing.
Weight estimation (approximate)
- 2× Vötsch VCS³ 4100-5-S base units: approx. 2 × 840 kg = 1,680 kg (typical catalog value per unit).
- Additional equipment/peripherals (rain, IR, vacuum, airflow, control cabinets, cabling, partition wall): approx. +400 to +900 kg.
- Water in tank (200 l): +200 kg during operation.
Guodjw S Ilkepfx Aaceh
- Transport “dry” (empty tank): approx. 2.1–2.6 t
- Operation “wet” (full tank): approx. 2.3–2.8 t
- Summary: approx. 2.1–2.8 t
Scope of delivery
- Vötsch VCS³ 4100-5-S indoor chamber
- Vötsch VCS³ 4100-5-S outdoor chamber
- Partition wall for VCS³ 4100-5-S
- Dimensions: Height × Width = 80 × 80 cm
- Rain/IR/vacuum/airflow units
- Condition: used
- Scope of delivery: (see picture)
(Changes and errors in technical data, specifications reserved!)
For further questions, please feel free to contact us by phone.
Listing

1,034 km
Assemblies / Test cabinet
VötschVT 3050 -30°C / +100°C 500 Liter
Call
Condition: excellent (used), Vötsch
Type: VT 3050
Modules / Test Chamber Temperature Chamber
Air-cooled
Test chamber capacity 500 litres
Temperature range -30°C / +100°C
Temporal temperature fluctuation K ±0.5
Spatial temperature fluctuation K ±1.5
Temperature gradient K 3
Change rate
Heating K/min 2.0
Cooling K/min 1.4
Heat compensation max. W 650
Gujdpfx Aaow S E N Tocjh
Calibration values +23°C +80°C
Test chamber dimensions Width 710 mm Depth 590 mm Height 1250 mm
External dimensions Width 940 mm Depth 1030 mm Height 1955 mm
Sound pressure level db(A)
Listing

1,034 km
Climate test chamber -10°C to +90°C
VötschVC 0018
Call
Condition: used, Vötsch
Model: VC 0018
Air-cooled climate test chamber
Test chamber dimensions: Width 580 x Depth 450 x Height 750 mm
Housing dimensions: Width 865 x Depth 1150 x Height 1780 mm
Test chamber volume: approx. 190 liters
Performance data for temperature tests:
Temperature range: -10 °C to +90 °C
Temperature deviation in steady-state, according to IEC 60068-3-5,
dependent on test chamber temperature
time-wise ±0.1 to ±0.5 K
spatially ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 0.6 K/min.
Cooling: 0.3 K/min.
Heat compensation in the range +20 °C to +50 °C: 200 W
Calibration values: +4 °C and +90 °C
Performance data for climatic tests:
Temperature range: +10 °C to +90 °C
Temperature deviation in steady-state, according to IEC 60068-3-5,
dependent on test chamber temperature
time-wise ±0.1 to ±0.3 K
spatially ±0.5 to ±1.0 K
Humidity range: 10% to 98% r.h.
Electrical connection:
Rated voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 1.7 kW
Rated current: 9.5 A
(Neutral conductor plug: loaded)
Gsdpfsw Swrtjx Aacsuh
Schuko approx. connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Weight: approx. 380 kg net
Refrigerant: R-134A
Buyer Information for Your Safety!
The following procedures are carried out on our climate chambers prior to sale:
1. Function check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
Technical specifications and information subject to change and errors!
Feel free to call us with any further questions.
Listing

1,034 km
Temperature test chamber -70°C to +180°C
VötschVT 7021
Call
Condition: excellent (used), Heraeus Vötsch
Type: VT 7021
Air-cooled temperature test chamber
1 port, nominal width 80 mm,
Test chamber volume: 210 liters
Godsw Rz Tlepfx Aaceuh
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (heating): 2.5 K/min
Temperature change rate (cooling): 2.5 K/min
Max. heat compensation: 800 W
Test chamber dimensions: Width 560 mm, Depth 570 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1250 mm, Height 1640 mm
Electrical connection: 1/NPE AC 230 V ± 10% 50 Hz
Rated power approx. 1.8 kW, rated current 12 A
Refrigerant: R404A and R23
Weight: 355 kg
For your safety as a buyer, please note the following information!
The following procedures are performed on the chambers we offer, in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Subject to technical modifications and errors in the details!)
For further questions, please feel free to contact us by phone.
Listing

1,034 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-15 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-15
Vötsch Climate Test Chamber, Water-Cooled
Temperature Test Data:
Temperature range: -70°C to 180°C
Temporal temperature deviation at center of workspace: ±0.3 to ±0.8 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 16 K/min
Cooling: 14.5 K/min
Climate Test Data:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temporal temperature deviation at center of workspace: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation at center of workspace: ±1 to ±3% RH
Maximum heat compensation: 8000 W
Enclosure dimensions:
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
Internal dimensions:
Height: 950 mm, Width: 1100 mm, Depth: 950 mm
Test chamber volume: approx. 1300 liters
Feedthroughs:
The test chamber is equipped with feedthroughs on both the right and left sides. These allow for test leads and testing devices to be routed into the chamber.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test chamber illumination:
Halogen bulb 24V, 50W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 44.0 kW
Rated current: 63.0 A
Customer-provided fuse: 100 A slow-blow
Maximum heat output to the environment: 2.2 kW
Permissible test item weight:
Godjwvgwbepfx Aacjuh
Total load on shelf supports: 100 kg
Test chamber floor: 150 kg, Removable shelf: 50 kg
Refrigerants: R 404A/R 23
Weight: 1900 kg
For your security as a buyer, please note:
The following steps are carried out in advance on our chambers offered for sale:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in the technical data and specifications!)
We are happy to answer any further questions by phone.
Trust Seal
Dealers certified through Machineseeker

Listing

1,034 km
Temperature test chamber 190 liters
VötschVT 7018 -70°C bis +180°C
Call
Operating hours: 630 h, condition: excellent (used), Vötsch
Model: VT 7018
Guodpfx Aaow Nqimjcjh
Air-cooled temperature test chamber
Only approx. 630 operating hours (read out)!
Test chamber dimensions: Width 580 x Depth 450 x Height 750 mm
External dimensions: Width 865 x Depth 1280 x Height 1780 mm
Test chamber volume: approx. 190 liters
Technical specifications for temperature tests:
Temperature range: -70 °C to +180 °C
Temperature deviation in steady state, according to IEC 60068-3-5
depending on the test chamber temperature
temporal ±0.1 to ±0.5 K
spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min.
Cooling: 2.3 K/min.
Thermal compensation max. 1000 W
Tube port L1: DN 50 mm
Tube port L2: DN 125 mm
Tube port R1 R2: DN 125 mm
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 5.9 kW
Rated current: 12 A
Protection: 16 A time-lag, to be provided by customer
Weight: approx. 460 kg net
Refrigerants: R 404A and R 23
Important safety information for you as a buyer!
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See image)
(Subject to change and errors in technical data!)
We are happy to answer further questions by phone.
Listing

1,034 km
Climate test chamber -10°C to +90°C
VötschVC 0018
Call
Condition: used, Vötsch
Model: VC 0018
Climate Test Chamber, Air-Cooled
Test Chamber Dimensions: Width 580 x Depth 450 x Height 750 mm
External Dimensions: Width 865 x Depth 1150 x Height 1780 mm
Test Chamber Volume: approx. 190 liters
Specifications for Temperature Testing:
Temperature Range: -10°C to +90°C
Temperature Deviation at steady state, according to IEC 60068-3-5,
depending on chamber temperature
over time: ±0.1 to ±0.5 K
spatial: ±0.5 to ±2.0 K
Godpfxew Hz S Uj Aaceuh
Temperature Change Rate according to IEC 60068-3-5
Heating: 0.6 K/min
Cooling: 0.3 K/min
Heat compensation in the range +20°C to +50°C: 200 W
Calibration Points: +4°C and +90°C
Specifications for Climate Testing:
Temperature Range: +10°C to +90°C
Temperature Deviation at steady state, according to IEC 60068-3-5,
depending on chamber temperature
over time: ±0.1 to ±0.3 K
spatial: ±0.5 to ±1.0 K
Humidity Range: 10% to 98% RH
Electrical Connection:
Rated Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 1.7 kW
Rated Current: 9.5 A (neutral conductor plug loaded), Schuko approx. connection cable: 3.5 m
Protection: 16 A slow-blow, provided by the customer
Weight: approx. 380 kg net
Refrigerant: R 134A
For your safety as a buyer, please note the following information!
The following points are carried out on all climate chambers we offer prior to delivery:
1. Functional check and replacement of necessary components
2. If necessary, a refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications and technical data are subject to change and errors are excepted!)
We are happy to answer any further questions you may have by phone.
Listing

1,034 km
Temperature test chamber 1540 liters
VötschVT³ 4150 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4150
Vötsch Temperature Test Chamber, Air-Cooled
Temperature Testing
Temperature Range: -40°C to +180°C
Rate of Change: Cooling approx. 2.5 K/min
Rate of Change: Heating approx. 3.5 K/min
External Dimensions (W x D x H): approx. 1390 x 2380 x 1995 mm
Gujdpow Ehutjfx Aacsh
Test Chamber Dimensions (W x D x H): approx. 1100 x 1475 x 950 mm
Rated Voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated Power: 11.5 kW
Rated Current: 22.0 A
Weight: approx. 1020 kg / 1540 liters
Refrigerant: R 404A
For your safety as a buyer, please note the following information:
We perform the following steps on all chambers offered:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: Used
Scope of delivery: (see photo)
(Technical data subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing

1,034 km
Temperature test chamber -70°C to +180°C
VötschVTS 7018-5 190 Liter
Call
Condition: excellent (used), Vötsch
Model: VTS 7018-5
Water-cooled Temperature Test Chamber
System retrofitted with R-452A
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature change rate cooling: 7.5 K/min
Temperature change rate heating: 7.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated power: 10.0 kW, Rated current: 21 A
Main fuse (on-site): 32 A slow-blow
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side port: 50 mm / 125 mm
Chamber is water-cooled
Refrigerants: R-452A and R 23
Weight approx. 460 kg
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, new charging with legally compliant refrigerant
3. Leak test with certificate
Gujdpowq Iymofx Aacsh
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Technical data may be subject to change or error!)
If you have any further questions, we will be happy to answer them by phone.
We make it easier for you to find: "voetsch"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Voetsch (107)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month