Description
*TECHNICAL SPECIFICATION:
Heating capacity: up to 54 kW
Cooling capacity: up to 300 kW
medium: water up to 200°C
Max. external volume: 43 ltr at 200°C
max. Flow rate: max. 230 l/min
Ksdog Ey T Eepfx Aaleww
max. delivery pressure: up to 8.3 bar
Motor power: up to 3 kW
Dimensions LxWxH: 1,460 x 525 x 1,200 mm
Weight approx. 330kg
Circulation medium connection: flange DN40 (DIN EN 1092-1), form B1
*HIGHLIGHTS EQUIPMENT:
-Control and regulation Smart Controller (7" touch display)
-Heating control via solid-state relay
-Control box IP54, externally ventilated
-Expansion tank, heater and piping stainless steel
-Heating via stainless steel tubular heating elements made of Incolloy
-Dirt trap (circulation)
-Unit ready for connection and mounted on castors, 2 of them steerable and with brake
-Cooling and filling controlled by solenoid valve
-configurable automatic filling via KW inflow or separate connection (factory-supplied via cooling water inflow)
-flow measurement by differential pressure principle
-Level monitoring by magnetic float switch
-automatic temperature-dependent system closure (not with WP7-90)
-flow monitoring by recording the flow rate
-Bypass between flow and return with reduced cross-section
-dirty filter in the cooling water inflow, filling and return of the circulation system
-Continuous bypass of the heat exchanger via 3-way motorised control valve (WP7-180/200)
-System pressure monitoring via pressure transmitter in the AD tank (WP7-150/180/200)
-Pressure booster pump for system filling (WP7-180/200, otherwise optional)
-Safety temperature limiter (STB) in the heater and flow (WP7-200)
-Pressure gauge in the supply line on the back of the unit
-heat-insulated circulation circuit (WP7-150/180/200)
Visit our website for more details or for other performance classes.
*This unit is compliant with the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Heating capacity: up to 54 kW
Cooling capacity: up to 300 kW
medium: water up to 200°C
Max. external volume: 43 ltr at 200°C
max. Flow rate: max. 230 l/min
Ksdog Ey T Eepfx Aaleww
max. delivery pressure: up to 8.3 bar
Motor power: up to 3 kW
Dimensions LxWxH: 1,460 x 525 x 1,200 mm
Weight approx. 330kg
Circulation medium connection: flange DN40 (DIN EN 1092-1), form B1
*HIGHLIGHTS EQUIPMENT:
-Control and regulation Smart Controller (7" touch display)
-Heating control via solid-state relay
-Control box IP54, externally ventilated
-Expansion tank, heater and piping stainless steel
-Heating via stainless steel tubular heating elements made of Incolloy
-Dirt trap (circulation)
-Unit ready for connection and mounted on castors, 2 of them steerable and with brake
-Cooling and filling controlled by solenoid valve
-configurable automatic filling via KW inflow or separate connection (factory-supplied via cooling water inflow)
-flow measurement by differential pressure principle
-Level monitoring by magnetic float switch
-automatic temperature-dependent system closure (not with WP7-90)
-flow monitoring by recording the flow rate
-Bypass between flow and return with reduced cross-section
-dirty filter in the cooling water inflow, filling and return of the circulation system
-Continuous bypass of the heat exchanger via 3-way motorised control valve (WP7-180/200)
-System pressure monitoring via pressure transmitter in the AD tank (WP7-150/180/200)
-Pressure booster pump for system filling (WP7-180/200, otherwise optional)
-Safety temperature limiter (STB) in the heater and flow (WP7-200)
-Pressure gauge in the supply line on the back of the unit
-heat-insulated circulation circuit (WP7-150/180/200)
Visit our website for more details or for other performance classes.
*This unit is compliant with the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2020
8 listings online
Send inquiry
Telephone & Fax
+49 170 6... show
These listings may also fit your interest.
Listing
Hadımköy
3,110 km
IMMERSIBLE ULTRASONIC WASHING UNIT
INTERSONIKSONDA
INTERSONIKSONDA
Listing
Bienne
1,301 km
Cylindrical grinding machine
SchaudtA440X1500
SchaudtA440X1500
Listing
Schorfheide
1,460 km
Crushing and/or screening plant
Sonstige/OtherGasparin Backenbrecher GI86C VULCANO
Sonstige/OtherGasparin Backenbrecher GI86C VULCANO
Listing
Germany
1,336 km
Surface and profile grinding machine
AmadaMeister G3
AmadaMeister G3
Listing
Melksham
474 km
Vemag Robot 500
VemagRobot 500
VemagRobot 500
Listing
Vaterstetten
1,520 km
Injection molding machine
KraussMaffei Technologies GmbHKM 80 / 380 CX G06
KraussMaffei Technologies GmbHKM 80 / 380 CX G06
Listing
Suffolk
617 km
High speed auto cartoner
Bradman LakeSL903
Bradman LakeSL903
Listing
Idstein
1,186 km
Bed type milling machine
ANAYAKPerformer 2000 MG
ANAYAKPerformer 2000 MG
Listing
Matelica (MC)
1,922 km
Milling Machines - A portale
PARPASDIAMOND LINEAR30
PARPASDIAMOND LINEAR30
Listing
Germany
1,293 km
CNC Milling and Drilling
Bimatec SoraluceSoramill SL4000
Bimatec SoraluceSoramill SL4000
Your listing has been deleted successfully
An error has occurred