Pulse generator for insulation testGBS Elektronik
rev3 Isolationstests bis 6nF
Pulse generator for insulation test
GBS Elektronik
rev3 Isolationstests bis 6nF
ONO plus VAT
€3,780
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Pulse generator for insulation test
- Manufacturer:
- GBS Elektronik
- Condition:
- like new (used)
Price & Location
ONO plus VAT
€3,780
- Location:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Call
Details about the offer
- Listing ID:
- A17569468
- Reference number:
- 21007
- Update:
- 05.08.2025
Description
GBS Test Pulse Rev. 3 Pulse Generator for Long-Term Insulation Tests
The test pulse design is designed for long-term insulation tests on test objects with capacitances up to 6 nF.
Converter for High-Voltage Test Transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation of the sine wave from 16-24 kHz via full bridge.
· Converter voltage adjustable from 0-600 V, Imax=2.6 A, maximum power 1.3 kW
· Pulse current limit 110 A (cut-off threshold)
Pulse Transformer Control
· Control via full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limit 100 A (cut-off threshold)
Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductors (150 μH, 300 μH) to adjust the pulse width and rise time to the load capacitance and voltage.
· Pulse repetition frequency (0.1 – 2.5 kHz), adjustable.
· Polarity: Adjustable positive, negative, or alternating depending on the polarity of the sine signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-way cascade circuit.
· Total transformation ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
Maximum output voltage 15 kV with possible load capacitances of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· 1:1000 parallel voltage divider.
· Overvoltage limitation at approx. 20-23 kV through parallel spark gaps.
· Thermistor for overtemperature detection in the first transformer stage.
Ltedpfx Asu Egz Rea Eoa
· Ground-side current measurement socket 100 mV/A.
Breakdown detection, test
· If the maximum bridge currents for the transformer controls or
if the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hours counter to determine the test time.
Manufacturer's price approx. €59,500
Find more items - new and used - in our shop!
International shipping costs on request!
The test pulse design is designed for long-term insulation tests on test objects with capacitances up to 6 nF.
Converter for High-Voltage Test Transformer
· Internal sine wave generator: 50-200 Hz.
· Pulse width modulation of the sine wave from 16-24 kHz via full bridge.
· Converter voltage adjustable from 0-600 V, Imax=2.6 A, maximum power 1.3 kW
· Pulse current limit 110 A (cut-off threshold)
Pulse Transformer Control
· Control via full bridge
· Full-bridge power supply adjustable from 0-1000 V, 1.3 A max.
· Pulse current limit 100 A (cut-off threshold)
Pulse width 20-120 μs, nominal 94 μs, adjustable
· 2 selectable series inductors (150 μH, 300 μH) to adjust the pulse width and rise time to the load capacitance and voltage.
· Pulse repetition frequency (0.1 – 2.5 kHz), adjustable.
· Polarity: Adjustable positive, negative, or alternating depending on the polarity of the sine signal.
· Cosine-shaped pulse at the transformer output
Pulse transformer cascade
· Output transformers in a 5-way cascade circuit.
· Total transformation ratio selectable as 1:7.7, 1:10, or 1:15 via taps.
Maximum output voltage 15 kV with possible load capacitances of: * 6 nF with a pulse width of 73 μs at a
repetition frequency of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition frequency of 1.25 kHz
· 1:1000 parallel voltage divider.
· Overvoltage limitation at approx. 20-23 kV through parallel spark gaps.
· Thermistor for overtemperature detection in the first transformer stage.
Ltedpfx Asu Egz Rea Eoa
· Ground-side current measurement socket 100 mV/A.
Breakdown detection, test
· If the maximum bridge currents for the transformer controls or
if the maximum currents of the bridge power supplies are exceeded, the high voltage is switched off.
· The device has a resettable operating hours counter to determine the test time.
Manufacturer's price approx. €59,500
Find more items - new and used - in our shop!
International shipping costs on request!
Seller
Note: Register for free or log in, to access all information.
Registered since: 2008
Send inquiry
Telephone & Fax
+49 2862 ... show
These listings may also fit your interest.
Listing
Kolbuszowa
2,080 km
Plastics processing machine
Koltex Plastic Recycling SystemsXR 8
Koltex Plastic Recycling SystemsXR 8
Listing
Soerendonk
967 km
Gear Unit / Gearbox
Flender / SiemensK2S-2,5
Flender / SiemensK2S-2,5
Listing
Wiefelstede
1,085 km
Bench vice 150 mm
Heuer FrontSpannweite 235 mm
Heuer FrontSpannweite 235 mm
Listing
Tönisvorst
1,025 km
Bezel 28427
mitlaufendSPH 150 mm
mitlaufendSPH 150 mm
Your listing has been deleted successfully
An error has occurred

















































