Temperature test chamber ex protectedCTS
T-30/950 Ex/I
Temperature test chamber ex protected
CTS
T-30/950 Ex/I
Year of construction
2011
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Temperature test chamber ex protected
- Manufacturer:
- CTS
- Model:
- T-30/950 Ex/I
- Year of construction:
- 2011
- Condition:
- excellent (used)
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A7538378
- Reference number:
- 23117
- Update:
- 27.06.2025
Description
CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Ltedpfx Asihb Amsa Eja
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
The listing was translated automatically. Translation errors are possible.
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Ltedpfx Asihb Amsa Eja
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2012
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Tata
1,972 km
Dry cooler fan cooler condenser
Güntner GVH 090.1.D/5-M(D)680,4 /579,2 kw
Güntner GVH 090.1.D/5-M(D)680,4 /579,2 kw
Listing
Hochdorf
1,342 km
Temperature Cooling Unit (TCU)
SingleCompact WK3-160-9-50 (IM160F)
SingleCompact WK3-160-9-50 (IM160F)
Listing
Berlin
1,445 km
Axial Condenser
Güntner AGGVH 100.2A/2x3-J(D)
Güntner AGGVH 100.2A/2x3-J(D)
Listing
Forst
1,259 km
100 m³ buffer tank, 3 bar, insulated
Listing
Delmenhorst
1,125 km
1000L pressure tank buffer tank
10539
10539
Listing
Schmölln
1,431 km
Cold room
Dresdner Kühlanlagenbau
Dresdner Kühlanlagenbau
Listing
Niedźwiedź
1,993 km
Refrigerant compressors system Bitzer
BitzerS6G-25.2Y (x4)
BitzerS6G-25.2Y (x4)
Listing
Nattheim
1,390 km
Standing panel saw
Holz-Her1255
Holz-Her1255
Listing
Borken
1,034 km
Climate test chamber with humidity 1000 liters
CTSC-40/1000 -40°C bis +180°C
CTSC-40/1000 -40°C bis +180°C
Listing
Wiefelstede
1,085 km
Ventilation system
HeimerWK-61
HeimerWK-61
Your listing has been deleted successfully
An error has occurred