Used Material testing for sale (495)
Sort results
- Lowest price Highest price
- Latest listings Oldest listings
- Shortest distance Farthest distance
- Latest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Latest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Latest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation A to Z
- Designation
- designation Z to A
- Designation
- Model A to Z
- Model
- Model Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest running time
- Runtime
- Relevance
- Relevance
Measuring & testing equipment Material testing
Listing

1,034 km
Shaker system with amplifier
LDSV895-440 HBT900C + SPA50K
Call
Condition: excellent (used), LDS
Type: V895-440 HBT900C with amplifier SPA50K
Technical data:
Cshxzouy H I Tsz Tvjgt
Fitting Dimensions: 440 mm
Sinusoidal force vector 55.6 kN (peak)
Rausch force vector 55.6 kN (effective)
Half sine force vector 166.8 kN (peak)
Frequency range 0 to 2100 Hz
Sinusoidal acceleration max. 981 m/s²
Noise Acceleration max. 490 m/s²
Speed max. 1.6 m/s
Deflection ± 63.5 mm
Oscillator mass 55 kg
Max. load 700 kg
Amplifier dimensions :
WxHxD mm : 537mm x 1905mm x 895mm
Weight 622 kg
Sliding table:
Work surface: 900 mm * 900 mm
Thickness of the top : 50 mm
Weight of the top: 80.4 kg
Max load : 7250kg
Effective frequency range 5-2000 Hz
Condition : gebraucht / used
Total weight (table + shaker): approx. 7000 kg
Shaker + table dimensions: LxHxW approx. 2700 x 1500 x 1800 mm
Scope of delivery: (see pictures)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,436 km
2 measuring devices
Exaktmess GmBHSondermaschine
Call
Year of construction: 2021, Condition: like new (used), Functionality: limited functionality, machine/vehicle number: 8001857, 2 special machines (measuring device) for dismantling the components
Cohxov Tywkszz Tvogt
Listing

1,543 km
Drum drying system for grass/hay/corn
Dutch Dryers BV.
Call
Condition: good (used), Complete drum drying system with an evaporation capacity of 12 t water/h
Cshxzzjtrdrke Tvegt
Including material feed
+ Multi-cyclone separator
+ Suction fan + Chimney
+ Hay cooler with filter
+ Pellet cooler
+ 2 balers
+ Belts, augers, elevator, etc.
The chipper and roller press have already been sold. However, we would be happy to assist you with the purchase of replacements.
We would be happy to send you more detailed information on the individual systems. Please also see our other listings. Individual sales possible upon request.
Prices are net, negotiable
no guarantee of availability

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month
Listing

1,032 km
White temperature cabinet -72°C - +180°C
Weiss Temperaturschrank -72°C - +180°CWT3-340/70 335 Liter Luftgekühlt
Call
Condition: excellent (used), Type: Weiss WT3-340/70
Very good condition
Weiss temperature cabinet with S!MCON / 32 control, air-cooled
(refrigerant (R-404A) (can be converted to R452A on request)
Test room capacity: approx. 335 liters
Test room dimensions: height 750 mm, width 580 mm, depth 765 mm
External dimensions: height 1775 mm, width 870 mm, depth 1600 mm
Cehxzz Tjv Edd Sjvsgt
Data for operation:
Test room lighting halogen bulb 24V, 50W
Nominal voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Nominal current: 12.5 A Nominal power 4.1 kW
Fuse provided by customer 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front. 1m height 58 dB(A)
Data for temperature tests:
Temperature range: -72 to +180 °C
Temperature deviation over time in the middle of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature gradient
(according to IEC 60068-3-5): 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 3.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 1500 W
Refrigerant: R-404A / R-23
Weight: 585 kg
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run with calibrated measuring devices.
Condition: used / used Very good condition
Listing

1,027 km
Climate test chamber +10°C to +90°C humidity
Heraeus VötschVC 0033
Call
Condition: ready for operation (used), Heraeus Vötsch VC 0033
Cgjhxzzsrpi Nbo Tvjt
Climatic test chamber
+10°C to +90°C
with humidity
Humidity range: 30 - 95
Test chamber dimensions: Width 570 x depth 540 x height 570 mm
Listing

1,867 km
Binder MKF 720 climatic chamber
BinderMKF 720
Call
Condition: excellent (used), operating hours: 100 h, PERFECT CONDITION, purchased in December 2016
Used for about 100h
New price is 46808 EURO
Cgshxjvldnqszz Tvet
The MKF series environmental simulation chamber from BINDER is ideal for all cold and heat tests, carried out on the basis of recognized temperature and climate test standards in accordance with DIN and IEC. High operating comfort and extensive standard equipment have obvious advantages in everyday use.
Key features
Temperature range:
-40 °C to 180 °C
Humidity range:
from 10 to 98% relative humidity
Integrated 20 L water tank
4 potential-free relay contacts
e™ preheating chamber technology
Programmable condensation protection for samples
Heated viewing window with internal LED lighting
Humidity control with capacitive humidity sensor and steam humidification
BINDER Multi Management Software APT-COM™ 4 Basic Edition
Diagnostics system with optical and acoustic alarm
Intuitive touchscreen controller with time interval programming and real-time programming
Internal data logger, measured values in open format can be read via USB
2 access ports with 80 mm silicone plug, left and right
Independent, adjustable temperature protection class 2 (DIN 12880) with optical alarm
4 castors, two with brakes
230 V socket on the side panel on the right
Ramp function can be set
Integrated line recorder
Time clock actual
Door heating
Alarm message in the event of lack of water in the fresh water tank
1 stainless steel wire shelf
Protection against leaking hoses, covering the water supply and discharge pipes up to a height of 1 m
Stainless steel interior
Halogen-free refrigerant R-404A
Cooling provided by a compressor unit
Listing

1,034 km
Climate test chamber 990 liters
WeissWK-1000/40/5 -40°C bis +180°C
Call
Condition: excellent (used), White
Type: WK-1000/40/5
Weiss climatic test chamber with Weiss air-cooled condenser
S!MCON / 32 control unit
Test chamber capacity: approx. 990 liters
Test chamber dimensions: Height 950 mm, width 1100 mm, depth 950 mm,
External dimensions: Height 1995 mm, width 1390 mm, depth 1855 mm,
Data for operation:
Test room lighting Halogen bulb 24V, 50W
Nominal voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 23 KW
Rated current: 33 A
Data for temperature tests:
Temperature range: -40 to +180 °C
Temperature deviation in time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate
Heating: 6.1 K/min
Cooling: 6.7 K/min
Heat compensation max. 5000 W
Data for climate tests
Temperature range: +10 to +95 °C
Cehxzju Ap Smsz Tvogt
Humidity range: 10 to 98 % r.h.
Temperature deviation in time in the center of the usable space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % r.h.
Dimensions incl. feet
Width x depth x height: 1190 x 1120 x 1093 mm
Refrigerant: R404 A 5.2 kg
Weight: approx. 840 kg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,927 km
Accelerated Light Fastness Tester
Heraeus Suntest CPS
Call
Condition: used, Functionality: fully functional, Heraeus Suntest CPS Accelerated Light Fastness Tester.
This tabletop accelerated light fastness tester of the brand Heraeus type Suntest CPS is used for exposure and weathering of material samples.
This method provides essential information on the long term response of products and materials to climatic conditions, in particular solar radiation.This Suntest CPS is suitable instrument for routine testing during production, for inspection of incoming goods or for screening new materials before production of finished goods.
Good working condition. Please check out our other listings as well.
Cehxzjwc Synez Tvegt
Listing

1,867 km
Binder MKF 400 E5 climatic chamber
BinderMKF 400 E5
Call
Condition: like new (used), Binder MKF 400 E5 climate chamber for sale.
The chamber is like new.
Manufacturer's description:
PRODUCT DESCRIPTION
The MKF series environmental simulation chamber from BINDER is ideal for all cold and heat tests carried out on the basis of recognized temperature and climate test standards in accordance with DIN and IEC standards. High operating comfort and extensive standard equipment have obvious advantages in everyday use.
Cohswb U Hnsxzz Tvsgt
MOST IMPORTANT FEATURES
Temperature range:
-40 ° C to 180 ° C
Humidity range:
from 10 to 98% relative humidity
Integrated 20 L water tank
4 potential-free relay connections
APT.line™ preheating chamber technology
Programmable condensation protection for samples
Heated viewing window with internal LED lighting
Humidity control with capacitive humidity sensor and steam humidification
BINDER Multi Management Software APT-COM™ 4 Basic Edition
Diagnostic system with optical and acoustic alarm
Intuitive touchscreen controller with time interval programming and real-time programming
Internal data logger, measured values in open format can be read via USB
Access port with 50 mm silicone plug, left side
Independent, adjustable temperature protection class 2 (DIN 12880) with optical alarm
4 castors, two with brakes
Interface for PC connection:
Ethernet
Ramp function can be set
Integrated line recorder
Time clock actual
Door heating
Alarm message in the event of lack of water in the fresh water tank
1 stainless steel wire shelf
Protection against leaking hoses, covering the water supply and discharge pipes up to a height of 1 m
Stainless steel interior
Halogen-free refrigerant R-452A
Cooling provided by a compressor unit
Listing

1,034 km
Temperature test chamber
Vötsch VT 4021
Call
Condition: used, Heraeus Vötsch
Type: VT 4021
Heraeus Vötsch temperature test chamber air-cooled
Housing dimensions: Width 850 mm Depth 1250 mm Height 1640 mm
Interior: Width 560 mm Depth 570 mm Height 630 mm
Temperature range -40°C to + 180°C
Temperature deviation in time ±0.2 to ±0.5 K
Spatial temperature deviation ±0.5 to ±1.5 K
Temperature change rate cooling 3.1 K/min
Temperature change rate heating 2.5 K/min
Nominal voltage: 1/N/PE AC 230V±10% 50Hz
Rated power: 1.5 kW Rated current: 7 A
2X side feed-through 90 mm
Refrigerant: R-404A
Weight approx. 325 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Cehxzzju Hf Hho Tvjgt
We will be happy to answer any further questions you may have on the phone.
Listing

1,034 km
Vibration test system
RMSSWR 900 SW 3709 u. TGD 6000
Call
Condition: excellent (used), RMS
Type: SW 3509 + amplifier TGD 6000-000.00 and fan
Test Manager SWR 900
Power amplifier: TGD 6000
Vibration exciter: SW 3709
High-pressure fan HVM 80-100 GL 270
RMS electrodynamic vibration test system:
Technical data system:
Performance data
Max. Vector force sine 7.5 kN
Max. Vector force noise 6.75 kN
Max. Vector force shock 13.1 kN
Frequency range 0 - 3000 Hz
Mass of the vibrating system (Dyn.) 9 kg
Main resonance (unloaded) 2.5 kHz
Max. Amplitude (sine) 18 mm
(noise, shock) 26 mm
Max. speed (sine) 1.5 m/s
(noise, shock) 2.5 m/s
Max. Acceleration sine
vibrating system unloaded 833 m/s²
Additional load 10 kg 394 m/s²
Additional load 30 kg 192 m/s²
Additional load 50 kg 127 m/s²
Max. Acceleration noise
Additional load 30 kg 173 m/s²
Max. Acceleration shock
vibrating system unloaded 1450 m/s²
Additional load 30 kg 335 m/s²
Stray field
Stray field without counter field coil
On the table surface 20 mT
120mm above the table surface 7 mT
Stray field with counter field coil
On the table surface 10 mT
120mm above the table surface 2 mT
Vibration isolator
Operating range vertical/ horizontal
Resonant frequency 2.7 Hz
Operating air pressure 5 bar
Pneumatic weight compensation
Max. Weight compensation 250 kg
Operating air pressure 2.3 bar
Cooling Vibration exciter air
min. Cooling air volume 9 m/min
Max. exhaust air temperature (based on room temperature 35°C) 80°C
Power booster air
Heat dissipation to room air 1.5 kw
Emission:
Sound pressure level
1m - distance at a height of 1.6m 105 dBA
Electromagnetic field SW 3709
Cjhxzeu Tud Hez Tvsgt
typ. 1.5 mT ( 50Hz)
typ. 0.5 mT (100Hz)
Electromagnetic field TGD 3000
typ. 150 HT (50Hz)
Dimensions / Weights
Table diameter / insert thread 224mm / M8
Vibration exciter with integrated isolators
970 × 695 x 950 mm (W x D x H)
Weight: 1200 kg
Power amplifier 550 x 700 x 2075 mm (W x D x H)
Weight: 270 kg
Cooling fan 839 x 582 x 900 mm (W x D x H)
Weight: 80 kg
Connection values:
Mains voltage +6/-10% 3 x 400V, 50Hz
Connected load 18 KVA
Power consumption (sweep mode sine wave) 12 kW
Total weight approx. 2000 kg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,034 km
Corrosion test cabinet for salt spray
VLM CC 1000-FL HL V.745.672.120
Call
Condition: good (used), VLM
Type: V.745.672.120 Model CC 1000-FL HL
Corrosion test chamber for salt spray tests
Specifications:
Test chamber volume: approx. 1000 L
Test chamber dimensions (ΒχΤχΗ1/Η2): 1400x800x800/1020 mm
Door opening dimensions (WxH): 1300x680 mm
External housing dimensions втн: 2162 x 995 x 2080 mm
Operating temperature range: 5°C > room temperature to +80°C
High-load version for loads up to 350 kg
Cjhxzz Tot Igc Sjvjgt
Process control: Beckhoff PLC, color touch screen display
display, 50 memory locations for test procedures, 50
Memory locations for test segments, ramps:
Humidity-temperature over the entire working range,
Ether connection
Electrical connection: 400 V, 50 Hz, 5700 W
Tap water: min. 2.5 bar Tap connection 3/4"
External thread for connecting an ion exchanger cartridge
Compressed air: 7-8 bar
Waste water: Siphon / 30 mm ID hose nozzle
Exhaust air: pipe end OD 75 mm
Operating systems:
Salt spray
Condensation water (CWC)
Ventilation Room air
Warm air
Controlled humidity
Listing

1,034 km
Temperature shock chamber
EspecTSA-201 SW
Call
Condition: excellent (used), Espec Temperature Shock Chamber
Here we offer you an Espec temperature shock chamber.
Thermal shock environmental chamber (cold load: -65° to 0°C). Conventional thermal shock chambers with three zones can be quite large because three separate chambers are used.
The TSA series has only one chamber, significantly reducing its size. Instead, it circulates cold, hot or ambient air as needed.
The conditioned air can be precooled or preheated beyond the set point, allowing for faster recovery to the desired condition after transfer.
Espec Temperature Shock Chamber Water Cooled TSA-201S SN: 153000154
Hot chamber: +60 to 200°C Cold chamber: -70 to 0°C
Working temperature: 0-40°C
System: two zone or three zone test by flap switching.
Performance:
Test range:
High temperature. Exposure range: +60 to +200°C
Low temperature. Exposure range: -70 to 0°C
Temperature variation ±0.5°C
Cgohxzjg S Ugkez Tvet
Hot chamber:
Temperature Heating time: ambient temp. to +200°C within 15 min.
Cooling chamber:
Temperature Pulldown time: ambient temp. to -75°C within 45 min.
Temperature recovery: within 10 min.
Inner dimensions (W x H x D mm): 650 x 460 x 670
External dimensions (W x H x D mm): 1550 x 1900 x 1670
Power supply: 380/400/415V AC 50Hz: 70 A
Refrigerant: R404/R23
Weight: approx. 1400 kg
Type: Espec Model: TSA-201 SW
For you as a buyer, the following information for your safety!
The following points are checked on our offered chambers in advance.
Listing

1,034 km
Analytical drift detector
Oxford InstrumentsINCAx-act
Call
Condition: excellent (used), Oxford Instruments
Here we offer you an INCAx-act Analytical Drift Detector.
Cgohxzehx Nchez Tvjt
Microanalysis of elements including boron and above
Operating temperature
Normal mode 10-25 degrees
Operating temperature
extended mode 10-30 degrees
Storage temperature
-25 to 40 degrees and 8 to 80% humidity non-condensing
Operating humidity
Listing

1,034 km
Cleanroom workbench
HeraeusHA 2472 BS
Call
Condition: excellent (used), Heraeus
Type: HA 2472 BS
Cleanroom workbench
for installation and operation in laboratories
Interior dimensions: 1,800 mm x 580 mm x 830 mm (length x depth x height)
Lighting, gas connection
Cgjhxjvyd Adszz Tvot
Condition: used
Scope of delivery. (See pictures)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing

1,034 km
Walk-in climate simulation cell
TIRAKB 127 TCZ 4022 S -2K -40 bis +140°C
Call
Condition: excellent (used), TIRA
Type: TCZ 4022 S -2K
Description: Air-cooled climate simulation cell
System structure:
The system consists of the following main components:
Walk-in, insulated cell
Air treatment room
Humidification system
Machine room
Switch cabinet
Technical data:
Performance range for temperature testing:
Temperature range -40...+140°C
Temperature constancy, in the supply air: (time-wise) ≤ ± 0.5°C
without them. Test room load according to (DIN 50011 Τ13) EN 60068
Temperature constancy, in the supply air: (spatial) ≤ ± 1.0°C
without thermal test room load according to (DIN 50011) EN 60068
Heating rate (according to DIN 50011) approx. 2.0 K/min
without thermal test room load (according to DIN 50011)
EN 60068) or test material in the temperature range of -30°C...+85°C
Cooling rate (according to DIN 50011) approx. 2.0 K/min
without thermal test room load (according to DIN 50011)
EN 60068) or test material in the temperature range of -30°C...+85°C
Performance range for climate test:
Temperature range +10...+90°C
Humidity working range 10...approx. 95% r.H
without thermal test room touch
Dew point temperature range +5...+89°C
without thermal test room touch
Humidity constancy (in the supply air) (time-wise) ≤ ± 2.5% r.H
measured in the supply air
Performance range for climate testing with heat compensation
Temperature range + 15...+ 80°C
Cohxzzevx S Hhs Tvsgt
Humidity 15...approx. 80% r.H
without thermal test room load
with max. 16 kW heat compensation
Dew point temperature range +10...+74°C
without thermal test room touch
Dimensions: test room (WxDxH) approx. 2260 x 4648 x 2260 mm
Dimensions: external dimensions (WxDxH) approx. 2660 x 6460 x 2800 mm
clear doorway test room door (W x H) 2260 x 2260 mm
climate module KB 127 (W x D x H) 1700 x 800 x 1400 mm
switch cabinet (W x D x H) 800 x 500 x 2000 mm
design:
air flow: supply air: perforated sheet on the rear wall, in the ceiling area
exhaust air: perforated sheet on the rear wall, in the floor area
temperature control:
direct cooling by evaporation of
refrigerant in a finned heat exchanger:
heating with electric resistance heater
dehumidification:
direct dehumidification by evaporation of
refrigerant in a heat exchanger
interior paneling: stainless steel
outer paneling: sheet steel, galvanized, plastic-coated
floor design: stainless steel,
floor load 15000 N/m²
wheel load (contact surface ≥4cm²) 1500 N/wheelDoor: double-leaf door, stainless steel, painted on the outside with
viewing window (WxH) l000xl000 mm
Test room lighting: 4 spotlights of 500 W each
Insulation Two-layer insulation, 80 mm PUR foam,
120 mm mineral wool
Refrigerator (1 piece) Bltzer 6G-30.2Y
Refrigerant, R449A!
Refrigeration machine oil SEZ 32
Steam humidifier (1 piece) EDB 40Color:
Cell RAL9010, white
Door RAL9010, white
Machine unit RAL 7032, pebble gray
Control cabinet RAL 7032, pebble gray
Mass:
Total system
approx. 4900 kg
Machine set KB 127 approx. 750 kg
Control cabinet approx. 120 kg
Humidification system approx. 64 kgConnections:
Nominal voltage 400 V +6%/-10% 3/PA 50Hz
Nominal power 95 kW
Nominal current 150 A
Listing

1,034 km
Resonance testing machine
SincoTecPower Swingly 20 kN EXCITING MOT
Call
Condition: used, SincoTec
Type: Exciting Mot
Resonance test bench POWER SWINGLY 20 kN
The resonance test bench POWER SWINGLY BigTable is designed as a two-mass oscillator.
It consists of an oscillating head excited by a frequency-controlled asynchronous motor using an unbalance motor,
which is arranged in the upper part of the machine and generates the dynamic amplitude.
The oscillating head is supported by pre-tensioned helical compression springs on the upper crossbeam and is guided centrally.
The medium-load drive is arranged in the lower part of the machine and applies the static preload
with the help of a gear motor via a spindle drive.
The sample space is located above the clamping table and is limited at the top by the adjustable crossbeam.
The test bench is controlled by the EXCITING MOT control system.
The complete control electronics for the control system are housed in an industrial PC cabinet.
The control cabinet is made of powder-coated sheet steel and meets protection class IP 50 according to EN 60529.
Technical data:
General data test bench:
Total height of test bench 1840 to 2240 mm
Height of machine table 1030 mm
Width of test bench 800 mm
Depth of test bench 1500 mm
Height of sample chamber max. 600 mm (without force transducer)
Free column passage 550 mm
Maximum force amplitude 10000 N
Maximum total force ±20000 N
Maximum vibration path ±5 mm
Test frequency 30 to 110 Hz
Accuracy of the measuring sensors min. Class 1 (according to DIN EN 10002-3)
Weight of test bench approx. 1880 kg
Max. weight of clamping device 150 kg
General data Control cabinet:
Total height of control cabinet 1900 mm
Cgohxzz Tjvx Su Sovjt
Height of table top 1080 mm
Width of control cabinet 650 mm
Depth of control cabinet 700 mm
Weight of control cabinet 152 kg
Color RAI 9006 (white aluminum), table top midnight
Conditions for the installation location:
Space requirement 2.5 x 2.5 m
Required ceiling height 2.8 m
Floor load capacity 170 N/cm²
Power supply 400 V / 50 Hz (clockwise rotating field)
Connection plug CEE socket, 2-pole, 16 A
Fuse 16 A
Connection and ambient conditions
Mains conditions:
Voltage 400 V rotating current with ΜΡ conductor and protective earth, clockwise rotating field
Voltage fluctuations < ± 10%
Short-term dips < 20 ms
Limits for continuous interference Radio interference level A according to VDE0871
Frequency 50 Ηz ± 1%
Protective earth Earthing resistance < 0.3 Ω
Model: POWER SWINGLY MOT
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing

1,034 km
Carbon-sulfur analysis
Leco C 230
Call
Condition: used, Leco
LECO C230 CARBON ANALYZER
Carbon analyzer C230
The LECO C230 carbon analyzer is a microprocessor-based,
software-controlled instrument for measuring the carbon and sulfur
sulfur content in metals, ores, ceramics and other inorganic
inorganic materials. The C230 uses an induction furnace
and measures carbon by infrared absorption.
The infrared (IR) source consists of nichrome wire, which is heated by
heated to 8500 °C by resistance heating. The IR source
emits visible energy and all wavelengths of the infrared spectrum
Carbon dioxide can be used for the description; the same principle applies to sulphur detection.
Carbon dioxide absorbs IR energy at a specific wavelength within the IR spectrum.
within the IR spectrum. Energy from the IR source is absorbed,
when the gas flows through the cell, preventing it from reaching the IR detector.
An IR cell is used both as a reference and for measurement.
Total carbon in the form of carbon dioxide is detected continuously and simultaneously.
The initial reference level or baseline for the detector is set by passing oxygen through the cell.
established by passing oxygen through the cell to drive out residual atmospheric gases.
Technical data:
Gas required:
Carrier gas: Oxygen 99.5 % pure, 40 psi
Pneumatic gas: Compressed air, nitrogen or argon, 40 psi (2.76 bar),
Source must be free of oil and water Gas flow (based on nominal analysis time)
Measurement: 3 liters per analysis
Pneumatic: 1 liter per analysis
Regulator
Oxygen: 501-291 O 2 pressure regulator
Compressed air: 766-036 Compressed air regulator
Inert gas: 764-216 Inert gas regulator
Furnace: Induction, 18 MHz, 2.2 kW
Data transmission: Included
Data storage
Without PC: 10 sample weights, 50 responses, 5 methods
Without PC: Internal membrane /External optional display
Cgjhxzz Tou Ndyxsvot
Without PC: Liquid crystal (16 x 26 characters)
Power requirement
Determinator: 230 Ṽ̃̃, ± 10 %, 50/60 Hz,
Single-phase, 15 amps max.
Operating current: 12 A
Standby current: 4 A
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

1,034 km
Mass spectrometer
SPECTRO AMETEK Spectromaxx
Call
Condition: used, Spectro
Type: SpectroMaxX LMD08 / LMX08 Date: 24.07.2020
Full analysis with the stationary spark spectrometer SpectroMaxX:
With the help of the spark spectrometer, the alloy contents and accompanying elements of macroscopic solid samples can be
can be determined with high precision down to the ppm range.
Different analysis methods are available for the base materials iron, aluminum, magnesium, copper, nickel, titanium and lead,
measuring methods adapted to the relevant alloy families are available.
Advantages:
Fast analysis within a few seconds
Highly accurate spectral analysis including C and N
Compact design (table-top device)
Areas of use / application:
Testing the chemical composition of 31 ferrous and non-ferrous metals
Composition of 31 ferrous and non-ferrous metals
metals, nitrogen and other elements
Description of the system:
Open spark stand for high sample throughput
Wide range of sample geometries possible
Simple change of base
Cjhsu S Ahqsxzz Tvegt
The following elements are available as a base: Al, Cu, Fe, Mg, Ni, Ti, Pb
The analyzable elements and concentration levels depend on the methods available for the respective base element
Usable wavelength range 170-670 nm
Output of measured values in concentrations or intensities
Selectable output units (%, ppm)
Output of statistical characteristic values (mean value, RSD)
SPECTROMAXx LMX08
Technical specifications:
CCD optics:
High-resolution CCD multi-detectors
Stabilized against temperature fluctuations
Effective wavelength range: 140-670 nm, the applicable and configured wavelength range is
wavelength range depends on the customer's application requirements.
Automated profiling
Analysis modules:
Freely selectable analysis modules
Optimized to customer requirements
Expansion with additional modules possible on site
Spark stand:
Open spark stand for high samples
Throughput and various sample geometries
Minimized argon consumption thanks to argon saving module
Optimized argon flow
Reduced cleaning intervals
Spark stand plate can be easily replaced
Temperature-absorbing design without water cooling
Integrated shutter system for optimum plasma view
Excitation system:
Fully digitized plasma generator with digital discharge definition,
digital pulse generation and digital offline pulse control
32 MHz microcontroller
Max. Spark duration: 4000 µs
Max. Spark power 4 kW
Display system:
Separate microcontroller for each CCD
Serial source interface
Spectrometer:
External, state-of-the-art computer
PC system with Windows operating system
Keyboard and mouse
Monitoring
Software:
Spark Analyzer Pro MAX software for analytical operation and calibration
Continuous automatic hardware diagnostics in the background
Automatic verification and identification of alloy/quality
Results Manager
Online maintenance scheduler
Ambient conditions:
Room temperature: 10-30°C
Conditions: (10-30°C)
Relative humidity:
Listing

1,034 km
Walk-in climate chamber
WeissWK 27'/50-150 -50°C bis 150°C
Call
Condition: excellent (used), White
Type: WK 27'/50-150
Climate cabinet
Water-cooled
Technical data:
Test cabinet designation: WK 27'/50-150
External dimensions
Height 3500 mm, width 3400 mm, depth 6000 mm
Control cabinet dimensions
Height 2000 mm, width 2400 mm, depth 400 mm
Internal dimensions
Height 3000 mm, width 3000 mm, depth 3000 mm
Floor load 30000 N/m³ (surface load)
Test chamber volume: approx. 27000 liters
Test specimen mass 1000 kg
Cold / heat operation
-50°C to 150°C
Heating 1.0 K/min
Cooling 1.0 K/min
Temperature stability +- 0.3 to 1.0 K (time-related)
Temperature stability +- 0.1 to 0.5 K (time-related)
Air conditioning operation
10 – 90°C
Humidity 10...98% r.h.
Temperature stability +- 0.1 to 0.5 K (time-related)
Dew point range +4 to +84 °C
3/N / PE AC 400 V ±10% 50 Hz
Weight: 7000 kg
Refrigerants R23 and R404A
With extra floor plates to increase floor load
The following information is for your safety as a buyer! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
Cgehxjvx Nfbjzz Tvot
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing

1,034 km
Alternating climate chamber environmental simulation
BinderMK 720 -40°C bis 180°C
Call
Condition: excellent (used), Binder
Type: MK 720
Environmental simulation cabinet for cyclic temperature tests.
The Binder cabinet of the MK series is suitable for all heat and cold tests between -40°C and 180°C.
The natural simulation through the APT.line preheating chamber technology is particularly unique.
It is a clever alternative to complex individual solutions for cyclic temperature tests.
External dimensions: width: 1340 mm, height 2100 mm
Depth plus 50 mm controller and door handle 1230 mm
Distance from wall 160 mm
Viewing window width 370 mm
Viewing window height 770 mm
Number of doors 1
Internal dimensions: width: 1000 mm, height: 1168 mm, depth: 600 mm
Interior volume 720 liters
No. Slots 5
Load per slot 40kg
Permissible total load 120kg
Empty weight 570kg
Temperature range -40°C to 180°C
Cgjhjvx Ndwoxzz Tvot
Electrical data
Nominal voltage 400 V 3 N ~ 50/60 Hz
Nominal power 6.0 kW 14.5 A
Calibration certificate here 12/19/2023
Refrigerant: R404 A
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information are reserved!)
We will be happy to answer any further questions you may have over the phone.
Trust Seal
Dealers certified through Machineseeker

Listing

1,034 km
Indentec hardness tester 60 to 150 kgf
Zwick / Roell4150DLC-A
Call
Condition: excellent (used), Zwick / Roell
Zwick Indentec hardness tester
Type: 4150DLC-A
Technical data:
Available test forces 60, 100 and 150 kgf
Power supply 115 / 230 V (50 - 60 Hz) 2/1A 1L/N/Pe
Cgshxzzsvxrxde Tvet
+ EO-4010C camera and ueye software
Condition: used
Weight approx. 60kg
Scope of delivery: (See image)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing

1,034 km
Temperature shock test chamber
WeissTS 130
Call
Condition: used, White
Type: TS 130
Temperature shock test chamber water-cooled
Specification:
Temperature range hot chamber +60°C … +220°C
Cohxzzjvwckho Tvegt
Temperature range cold chamber -10°C … -80°C
Switch between hot and cold chambers 10 sec.
Temperature stability ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge) without....approx. 1820 mm with....approx. 1850 mm
Depth (without and with test chamber door) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket (test room) height 450 mm, width 500 mm, depth 600 mm
Volume 130 liters
Test room load max. 20 kg
Test room floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device approx. 65 dB(A)
Water-cooled cooling cascade
Connection values: 3/N/PE/AC 400V ±10% 50Hz /14.0 kW
Rated current 26.0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
More We will be happy to answer any questions you may have over the phone.
Listing

1,034 km
FT-IR spectrometer
BrukerTensor 27
Call
Condition: used, Bruker
Type: Tensor 27
IR spectrometer
Full sample flexibility.
The improved QuickLockTM mechanism and the locking button on the front
even bulky accessories can be installed quickly and, above all, safely.
The INVENIO can also be equipped with three software-controlled beam outputs for a variety of external modules.
Cshevwcikexzz Tvsgt
FPA micro and macro imaging
Variable external sample chamber (left and right) for individual experiments
Fiber optic coupling to fiber probes for liquids and solids
Integration sphere
Autosampler for liquids
High-throughput analysis module HTS-XT
Reflection unit for the air-water phase boundary
Much more!
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing

1,034 km
Temperature cabinet 2240 liters
Mytron T2240 –40°C bis +100°C
Call
Condition: used, mytron
Type: T2240
Temperature cabinet, water-cooled
Technical data:
External dimensions: width 1435 mm, height 1955 mm, depth 2590 mm
Dimensions of the test chamber: width 1050 mm, height 1400 mm, depth 1600 mm
Volume of the test chamber: approx. 2240 l
Opening for cables:
2 x 100 mm right
2 x 100 mm left
Temperature range: – 40 °C to + 100 °C at 23 °C room temperature
Temperature stability over time: +/- 0.5 °K
Temperature stability over space: +/- 1.0 °K
Cooling: water cooling,
Inlet and outlet 1" internal thread
Cooling water shut off by solenoid valve when device is OFF
Cgshxzsvtl Hqjz Tvet
Fault display in the event of a refrigeration machine error
Cooling water consumption: Inlet temperature approx. 15 °C, approx. 15 l/min,
Drain temperature approx. 22 °C (with continuous cooling approx. 27 °C)
Mains connection: 3NPE AC 50 Hz 400 V, 32 A CEE plug
Power consumption: approx. 6.5 kVA
Fuse protection: 3 x 20.0 AT, 3 x 10.0 AT
Lighting: 25 watts each on the left and right side of the test room
Exhaust air connection: DN 100 mm plug-in system
Safety device: electronic overtemperature protection, permanently set
Flue gas monitoring with horn
Viewing window: five-pane glazing 130 x 360 mm
Refrigerant: R 404 A approx. 10 kg
Weight: approx. 850 kg
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
We make the search easier for you
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Material testing (495)
Search Machineseeker now with more than 200,000 used machines:This may be of interest to you

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month