Differential scanning calorimeterPerkin Elmer
DSC 8000, N5340524
Differential scanning calorimeter
Perkin Elmer
DSC 8000, N5340524
EXW Fixed price plus VAT
€29,750
Condition
Used
Location
Dresden 

Show images
Show map
Machine data
- Machine type:
- Differential scanning calorimeter
- Manufacturer:
- Perkin Elmer
- Model:
- DSC 8000, N5340524
- Condition:
- used
Price & Location
EXW Fixed price plus VAT
€29,750
- Location:
- Heilbronner Str. 22, 01189 Dresden, Deutschland

Call
Details about the offer
- Listing ID:
- A21283042
- Reference number:
- LW43630
- Update:
- 20.02.2026
Description
Perkin Elmer Instruments Differential Scanning Calorimeter with Cooling, DSC 8000, N5340524
Model: DSC8000
Type: N5340524
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000, equipped with Intracooler 2. Enables precise heat flow measurements from approx. –70 °C to 750 °C with high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Dual furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Temperature Performance
Standard temperature range: approx. –180 °C to 750 °C (with suitable cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and fast response due to low-mass furnace design
Excellent baseline stability and temperature accuracy
Gas and Atmosphere Control
Two regulated gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photocalorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power consumption 400 VA
Accessories
Cooling system: PolyScience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
Autosampler with 96 positions
Gusdsyluicopfx Afcea
High-pressure DSC cells, UV/photocalorimeter accessories
IEC power connection
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on Item Condition:
Without software/PC
The listing was translated automatically. Translation errors are possible.
Model: DSC8000
Type: N5340524
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000, equipped with Intracooler 2. Enables precise heat flow measurements from approx. –70 °C to 750 °C with high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Dual furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Temperature Performance
Standard temperature range: approx. –180 °C to 750 °C (with suitable cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and fast response due to low-mass furnace design
Excellent baseline stability and temperature accuracy
Gas and Atmosphere Control
Two regulated gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photocalorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power consumption 400 VA
Accessories
Cooling system: PolyScience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
Autosampler with 96 positions
Gusdsyluicopfx Afcea
High-pressure DSC cells, UV/photocalorimeter accessories
IEC power connection
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on Item Condition:
Without software/PC
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2014
97 listings online
Send inquiry
Telephone & Fax
+49 351 8... show
These listings may also fit your interest.
Listing
Hannover
1,208 km
Desktop Metal Studio System II
Desktop MetalStudio System II
Desktop MetalStudio System II
Listing
Borken
1,034 km
10°C to +250°C / 749 liters
Memmert Universal - WärmeschrankUFP 800
Memmert Universal - WärmeschrankUFP 800
Listing
Borken
1,034 km
Universal test chamber +20 °C to +300 °C
MemmertUF 450plus
MemmertUF 450plus
Listing
Wald
1,366 km
Universal oven / heat cabinet
MemmertULP 600
MemmertULP 600
Listing
Spain
1,192 km
DESKTOP METAL Metal Studio 2
DESKTOP METALMetal Studio 2
DESKTOP METALMetal Studio 2
Your listing has been deleted successfully
An error has occurred