Bioer Quant Gene 9600 Fluorescent Quantitative Detection SystemBioer Quant Gene 9600
Gene 9600
Bioer Quant Gene 9600 Fluorescent Quantitative Detection System
Bioer Quant Gene 9600
Gene 9600
Condition
Used
Location
Duxford 

Machine data
Price & Location
- Location:
- Duxford, UK

Call
Details about the offer
- Listing ID:
- A20124805
- Reference number:
- PR-001.SR4C
- Update:
- 30.03.2026
Description
This listing is for the Bioer Quant Gene 9600 Fluorescent Quantitative Detection System
The unit is in full working condition and is ready for immediate use
Bioer LineGene Plus 9600 FQD-96A – Fluorescent Quantitative Detection System
Key Specifications
Sample Capacity: 96-well 0.2 mL PCR plates, 12 × 8-strip tubes, or 96 × 0.2 mL single tubes (transparent bottom)
Reaction Volume: 5–100 µL
Dynamic Range: 1–10¹⁰ copies/µL
Detection Channels: 5 or 6 channels (F1–F6)
Excitation Wavelength: 300–800 nm
Emission Wavelength: 500–800 nm
Temperature Range: 4–105°C (0.1°C increments)
Temperature Control Accuracy: ±0.1°C
Temperature Uniformity: ≤ ±0.3°C
Heating Rate: Up to 4.0°C/s
Cooling Rate: Up to 4.0°C/s
Cjdpfx Aoxhgfgeidjrc
Hot Lid Temperature Range: 30–110°C (adjustable, default 105°C)
Gradient Temperature Range: 1–36°C
Scanning Mode: Full-plate scanning and designated line scanning (5.5 seconds per scan)
Programming: Up to 20 segments per program, up to 99 cycles
Operating System Compatibility: Windows 7/8/10
Software Requirements: Microsoft Excel 2000/2002/2003/2007/2012
Minimum Computer Configuration: RAM: 512 MB; Hard Disk: 10 GB; CPU: Pentium 4; Virtual Memory: ≥1000 MB
Power Supply: 100–240V, 50/60Hz, 600W
Dimensions: 410 mm (W) × 386 mm (D) × 352 mm (H)
Weight: Approximately 20 kg
Certifications: CE, EMC, RoHS2.0, MET
.
The unit is in full working condition and is ready for immediate use
Bioer LineGene Plus 9600 FQD-96A – Fluorescent Quantitative Detection System
Key Specifications
Sample Capacity: 96-well 0.2 mL PCR plates, 12 × 8-strip tubes, or 96 × 0.2 mL single tubes (transparent bottom)
Reaction Volume: 5–100 µL
Dynamic Range: 1–10¹⁰ copies/µL
Detection Channels: 5 or 6 channels (F1–F6)
Excitation Wavelength: 300–800 nm
Emission Wavelength: 500–800 nm
Temperature Range: 4–105°C (0.1°C increments)
Temperature Control Accuracy: ±0.1°C
Temperature Uniformity: ≤ ±0.3°C
Heating Rate: Up to 4.0°C/s
Cooling Rate: Up to 4.0°C/s
Cjdpfx Aoxhgfgeidjrc
Hot Lid Temperature Range: 30–110°C (adjustable, default 105°C)
Gradient Temperature Range: 1–36°C
Scanning Mode: Full-plate scanning and designated line scanning (5.5 seconds per scan)
Programming: Up to 20 segments per program, up to 99 cycles
Operating System Compatibility: Windows 7/8/10
Software Requirements: Microsoft Excel 2000/2002/2003/2007/2012
Minimum Computer Configuration: RAM: 512 MB; Hard Disk: 10 GB; CPU: Pentium 4; Virtual Memory: ≥1000 MB
Power Supply: 100–240V, 50/60Hz, 600W
Dimensions: 410 mm (W) × 386 mm (D) × 352 mm (H)
Weight: Approximately 20 kg
Certifications: CE, EMC, RoHS2.0, MET
.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2019
797 listings online
Send inquiry
Telephone & Fax
+44 20 38... show
These listings may also fit your interest.
Listing
Győr
1,927 km
Blood Gas Analyzer
Instrumentation LaboratoryGEM Premier 4000
Instrumentation LaboratoryGEM Premier 4000
Listing
Piskorzów
1,745 km
Laboratory autoclave
SystecDE - 150
SystecDE - 150
Listing
Langenfeld (Rheinland)
1,065 km
Slitter rewinder
Neolt Electro Trim 150 Rollenschneiderfrom 2021
Neolt Electro Trim 150 Rollenschneiderfrom 2021
Listing
Wymysłów
1,785 km
WNT SK40 tool holder Ø12x80 G2.5 25000 rpm + ventilated drill bit
Oprawka WNT SK40 Ø12x80 G2.5 25000 obr/min + wentylowane wiertłoOprawka WNT SK40 Ø12x80 G2.5 25000 obr/min + wentylowane wiertło
Oprawka WNT SK40 Ø12x80 G2.5 25000 obr/min + wentylowane wiertłoOprawka WNT SK40 Ø12x80 G2.5 25000 obr/min + wentylowane wiertło
Listing
Bad Tennstedt
1,321 km
Laboratory table with wall shelf
Your listing has been deleted successfully
An error has occurred