Climate test chamber 190 litersVötsch
VC³ 7018 -70°C bis +180°C
Climate test chamber 190 liters
Vötsch
VC³ 7018 -70°C bis +180°C
Condition
Used
Location
Borken 

Machine data
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A20748272
- Reference number:
- 24927
- Update:
- 12.12.2025
Description
Vötsch
Type: VC³ 7018
Vötsch Air-Cooled Climatic Test Chamber
Temperature Test:
Dksdjx Hg Uujpfx Aqvjn
Temperature Range: -70°C to +180°C
Temperature Rate: Heating 4 K/min
Temperature Rate: Cooling 3 K/min
Climatic Test:
+10°C to +95°C
Humidity Range: 10% to 98% RH F.
Temperature deviation over time: ± 0.1 to ± 0.3 K
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Nominal voltage: 400 V
Nominal current: 14 A
Nominal power: 5.5 kW
Heat compensation 1500 W (at 20+)
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Type: VC³ 7018
Vötsch Air-Cooled Climatic Test Chamber
Temperature Test:
Dksdjx Hg Uujpfx Aqvjn
Temperature Range: -70°C to +180°C
Temperature Rate: Heating 4 K/min
Temperature Rate: Cooling 3 K/min
Climatic Test:
+10°C to +95°C
Humidity Range: 10% to 98% RH F.
Temperature deviation over time: ± 0.1 to ± 0.3 K
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Nominal voltage: 400 V
Nominal current: 14 A
Nominal power: 5.5 kW
Heat compensation 1500 W (at 20+)
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Balaguer
1,461 km
Welding machine
KEMPPIPRO 3000
KEMPPIPRO 3000
Listing
Germany
1,414 km
Welding Unit
KEMPPIPro MIG 500
KEMPPIPro MIG 500
Listing
Borken
1,034 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Listing
Saarbrücken
1,149 km
Multisensor measuring machine Mahr MS222
MahrMS 222 Komplettpaket mit Lieferung*
MahrMS 222 Komplettpaket mit Lieferung*
Listing
Crailsheim
1,356 km
Tugger
RofanTPR-10
RofanTPR-10
Listing
Weilheim an der Teck
1,351 km
ACCURA II MASS 16/42/15
ZeissACCURA II MASS 16/42/15
ZeissACCURA II MASS 16/42/15
Listing
Borken
1,034 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
WeissSB2/500/80 -75°C bis +180°C
Listing
Mönchengladbach
1,031 km
Coordinate measuring machine
MitutoyoEuro C Apex 9166
MitutoyoEuro C Apex 9166
Listing
Denkendorf/Bitz
1,459 km
Coordinate measuring machine
ZeissSMM-C Duplex DSE
ZeissSMM-C Duplex DSE
Listing
Mönchengladbach
1,031 km
Coordinate measuring machine
MitutoyoEuro C Apex 7106
MitutoyoEuro C Apex 7106
Your listing has been deleted successfully
An error has occurred