Shaker SALL50F + climate chamberUnholtz-Dickie
TA117SA-560 Vibrationsprüfanlage
Shaker SALL50F + climate chamber
Unholtz-Dickie
TA117SA-560 Vibrationsprüfanlage
Fixed price plus VAT
€28,000
Condition
Used
Location
Borken 

Machine data
Price & Location
Fixed price plus VAT
€28,000
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A21952263
- Reference number:
- 25207
- Update:
- 19.05.2026
Description
UNHOLTZ-DICKIE / HS-Simulators Vibration Testing System
Type: TA117SA-560 + HS 520 K 60 V
Manufacturer: UNHOLTZ-DICKIE Corporation / HS-Simulators Horstmann GmbH
For sale is a complete electrodynamic vibration testing system consisting of an UNHOLTZ-DICKIE shaker system, SALL50F power amplifier, VWIN II control system, and an HS-Simulators climate chamber. Ideal for combined vibration and climate testing in industrial, automotive, aerospace, electronics testing, as well as research and development applications.
The hall crane / other hall equipment visible in the pictures is not included in the scope of supply.
Shaker / Vibrator
Manufacturer: UNHOLTZ-DICKIE Corporation
Type: 560
System: TA117SA-560
Serial Number: 259
Air-cooled electrodynamic shaker
Sine force: 6000 lbf peak / 26.7 kN peak
Random force: 5200 lbf RMS / 23.1 kN RMS
Max. acceleration of free table: 100 g / 981 m/s²
Shaker stroke: 1 inch / 25.4 mm
Axial resonance frequency: approx. 2200 Hz / approx. 2.2 kHz
Armature effective weight:
45 lb / approx. 20.4 kg
Driver Coil:
200 A Sine
140 A Random
Air-cooled and vibration-isolated system.
Power Amplifier
Manufacturer: UNHOLTZ-DICKIE Corporation
Type: SALL50F Power Amplifier
Serial Number: 4414
Power Module: PML-50-S
Master Controller: MCLL50
Supply voltage:
400 V / 3 Phase / 50 Hz
Power consumption:
41 kVA / 60 A
Blower: 15 kVA / 22 A
Maximum Driver Currents:
440 A RMS OUT SINE
300 A RMS OUT RANDOM
Forced air cooling.
Control System
UNHOLTZ-DICKIE VWIN II DSP Vibration Control System
including industrial PC / monitor as shown in the pictures
Control Console:
MA117SA-560
Serial Number: 1838
Charge Amplifier:
Type 122P
Serial Number: 8963
Supported test types:
Random Vibration
Sine Vibration
Resonance Dwell
Classical Shock Pulse
SRS Shock & Analysis
Sine-on-Random
Random-on-Random
Gunfire
Interfaces:
TCP/IP
RS232
Ethernet
USB
HS-Simulators Climate Chamber
Manufacturer: HS-Simulators Horstmann GmbH
Type: HS 520 K 60 V
Temperature range: -60 °C to +180 °C
Electrical data:
380 V
17 A
10 kW
Refrigerant:
R13
R502
Features:
Combined climate and vibration testing
Complete electrodynamic testing system
DSP-based real-time control
Forced air cooling system
Completely wired testing system
Original documentation available:
Operating Manual
Maintenance Manual
System Specifications
System Diagrams
Performance Curves
Dimensions / Weight
Amplifier:
approx. 1000 x 537 x 825 mm
Climate chamber:
approx. 1200 x 1800 x 2000 mm
Total weight estimated:
approx. 2500 – 4000 kg
Transportation only by a suitable heavy-duty transport company.
Technical data partially estimated.
Specifications may vary.
Condition
Used system from industrial application.
Optical condition see pictures.
Functionality not fully tested.
Inspection possible and desired upon agreement.
Scope of delivery
UNHOLTZ-DICKIE shaker model 560
SALL50F power amplifier
Control console / control system
VWIN II controller system
Charge amplifier
HS-Simulators climate chamber HS 520 K 60 V
Industrial PC / monitor as shown in the pictures
Documentation and accessories as shown in the pictures
Hodpsy S S Eisfx Ad Rjn
Loading possible upon agreement.
Commercial sale without warranty.
Errors and prior sales excepted.
The listing was translated automatically. Translation errors are possible.
Type: TA117SA-560 + HS 520 K 60 V
Manufacturer: UNHOLTZ-DICKIE Corporation / HS-Simulators Horstmann GmbH
For sale is a complete electrodynamic vibration testing system consisting of an UNHOLTZ-DICKIE shaker system, SALL50F power amplifier, VWIN II control system, and an HS-Simulators climate chamber. Ideal for combined vibration and climate testing in industrial, automotive, aerospace, electronics testing, as well as research and development applications.
The hall crane / other hall equipment visible in the pictures is not included in the scope of supply.
Shaker / Vibrator
Manufacturer: UNHOLTZ-DICKIE Corporation
Type: 560
System: TA117SA-560
Serial Number: 259
Air-cooled electrodynamic shaker
Sine force: 6000 lbf peak / 26.7 kN peak
Random force: 5200 lbf RMS / 23.1 kN RMS
Max. acceleration of free table: 100 g / 981 m/s²
Shaker stroke: 1 inch / 25.4 mm
Axial resonance frequency: approx. 2200 Hz / approx. 2.2 kHz
Armature effective weight:
45 lb / approx. 20.4 kg
Driver Coil:
200 A Sine
140 A Random
Air-cooled and vibration-isolated system.
Power Amplifier
Manufacturer: UNHOLTZ-DICKIE Corporation
Type: SALL50F Power Amplifier
Serial Number: 4414
Power Module: PML-50-S
Master Controller: MCLL50
Supply voltage:
400 V / 3 Phase / 50 Hz
Power consumption:
41 kVA / 60 A
Blower: 15 kVA / 22 A
Maximum Driver Currents:
440 A RMS OUT SINE
300 A RMS OUT RANDOM
Forced air cooling.
Control System
UNHOLTZ-DICKIE VWIN II DSP Vibration Control System
including industrial PC / monitor as shown in the pictures
Control Console:
MA117SA-560
Serial Number: 1838
Charge Amplifier:
Type 122P
Serial Number: 8963
Supported test types:
Random Vibration
Sine Vibration
Resonance Dwell
Classical Shock Pulse
SRS Shock & Analysis
Sine-on-Random
Random-on-Random
Gunfire
Interfaces:
TCP/IP
RS232
Ethernet
USB
HS-Simulators Climate Chamber
Manufacturer: HS-Simulators Horstmann GmbH
Type: HS 520 K 60 V
Temperature range: -60 °C to +180 °C
Electrical data:
380 V
17 A
10 kW
Refrigerant:
R13
R502
Features:
Combined climate and vibration testing
Complete electrodynamic testing system
DSP-based real-time control
Forced air cooling system
Completely wired testing system
Original documentation available:
Operating Manual
Maintenance Manual
System Specifications
System Diagrams
Performance Curves
Dimensions / Weight
Amplifier:
approx. 1000 x 537 x 825 mm
Climate chamber:
approx. 1200 x 1800 x 2000 mm
Total weight estimated:
approx. 2500 – 4000 kg
Transportation only by a suitable heavy-duty transport company.
Technical data partially estimated.
Specifications may vary.
Condition
Used system from industrial application.
Optical condition see pictures.
Functionality not fully tested.
Inspection possible and desired upon agreement.
Scope of delivery
UNHOLTZ-DICKIE shaker model 560
SALL50F power amplifier
Control console / control system
VWIN II controller system
Charge amplifier
HS-Simulators climate chamber HS 520 K 60 V
Industrial PC / monitor as shown in the pictures
Documentation and accessories as shown in the pictures
Hodpsy S S Eisfx Ad Rjn
Loading possible upon agreement.
Commercial sale without warranty.
Errors and prior sales excepted.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Iserlohn
1,099 km
Surface and profile grinding machine
Ziersch & BaltruschPROFITLINE ZB 62 NC
Ziersch & BaltruschPROFITLINE ZB 62 NC
Listing
Burgoberbach
1,385 km
CNC surface grinding machine
Geibel & HotzG&H FS 415-Z SL
Geibel & HotzG&H FS 415-Z SL
Listing
Dortmund
1,087 km
Precision surface grinding machine
PERFECTPFG-CL 3060 AH
PERFECTPFG-CL 3060 AH
Listing
Heemskerk
872 km
Envelope inserting system mail processor
Winkler + Dünnebier (W+D) BuhrsBB700 S1
Winkler + Dünnebier (W+D) BuhrsBB700 S1
Listing
Hannover
1,209 km
Injection molding machine
KraussMaffeiKM 250-1000 CX
KraussMaffeiKM 250-1000 CX
Listing
Bielefeld
1,145 km
CNC Cutter Knife
expert international gmbhcut expert ecocam 2
expert international gmbhcut expert ecocam 2
Listing
Hagen
1,097 km
Surface grinding machine
BernardoFSM 3060 AHD
BernardoFSM 3060 AHD
Listing
Sonneberg
1,372 km
Surface grinding machine G+H FS640Z CB
Listing
Stockstadt am Rhein
1,220 km
Surface Grinding Machine - Horizontal
KraftFS 2550
KraftFS 2550
Listing
Stuttgart
1,315 km
FLAT GRINDING MACHINE
JungJF 520
JungJF 520
Your listing has been deleted successfully
An error has occurred