Used Hydraulic Cooling Unit for sale (45,292)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Ennepetal
1,084 km
Hydraulic Pumps Unit
FLUIDSYSTEME DASBECK400l - Sofort einsatzbereit
Call
Condition: used, Year of construction: 2010, tank capacity 400 l
Hodpfx Aqjm Sk Rgetjr
working pressure 35 U,210 bar
feed pressure / bar
weight 900 kg
required space 1,72 x 1,00 x 1,81 m
Listing
Wiesbaden
1,190 km
Hydraulic unit
DAIKINT-V 38*A3ARX-95
Call
Condition: ready for operation (used), machine/vehicle number: YC-67958, Max. operating pressure: 210 bar
Drive motor: 380 V, 11/13.2 kW
Oil tank: 500 x 900 x 600 mm (height)
Oil tank capacity: 250 l
Space requirement: 1150 x 700 x 1070 mm (height)
Hodpsd Efdyjfx Aqtor
Listing
Hessisch Lichtenau
1,244 km
High-pressure hydraulic power unit up to 630 bar, hydraulic spreader jaws, hydraulic spreader, high-
WEBERE45 / 59600.0 -- SP30 / 59 198.0
Call
Condition: used, High-pressure hydraulic power unit up to 630 bar, WEBER Type E45 / 59600.0
High-pressure unit + hydraulic spreader
Year of manufacture 1988 / 1986
Hydraulic power unit, Type E45 / 59600.0
Operating pressure max. 630 bar
Flow rate approx. 2 l/min
Tank capacity approx. 10 liters
Spreader – jaws, WEBER Type SP30 / 59 198.0
Outreach = arm length 340 mm
Spreading distance max. 610 mm
Spreading force in the working area max. 132 kN
Closing force 99 kN
- Double hose with plug-in connection
Rated power 0.9 kW
Mains connection 220 volts, 50 Hz
Weight of hydraulic power unit approx. 40 kg
Weight of spreader approx. 25 kg
Very good condition
Hydraulic fire and rescue set with hydraulic power unit and a spreader.
The spreader is used to create rescue openings after traffic accidents by spreading apart.
It can also be used to compress or lift loads.
Versatile due to the multifunctional spreader jaws made of die-forged and hardened steel.
Hedpfsdzp S Rjx Aqtjr
Listing
Ennepetal
1,084 km
Hydraulic Pumps Unit
NACHIHydraulikaggregat NACHI S-0265
Call
Condition: used, Year of construction: 1990, tank capacity 160 l
feed pressure 160 bar
weight / kg
Hydraulic power pack - NACHI S. hydraulic unit
Manufacturer: NACHI-FUJIKOSHI CORP. (Japan)
Type: Hydraulic equipment
Model/serial number: S
Year of manufacture: 12/1990
Condition: Used, fully functional, with hydraulic filter, valve unit and motor
Application: Suitable for machine tools, presses, automation technology
3. hydraulic pump
Manufacturer: NACHI-FUJIKOSHI CORP. (Japan)
Model: UPV-1A-22M1-2.2-4
Hsdeylz D Tepfx Aqter
Power: 2.2 kW
Type: UNI PUMP - compact pump with integrated motor
Connections: Standard industrial thread
Construction: Compact unit - ideal for retrofit or replacement
Origin: Dismantled directly from MAZAK machining centre
Condition: Used, ready for operation, suitable for oil temperature control in hydraulic systems
The unit was dismantled from a MAZAK machining centre and was in perfect working order until it was dismantled.
Listing
Germany
1,228 km
Hydraulic pump unit
ROEMHELD
Call
Condition: used, machine/vehicle number: 8422 151, Maximum pressure: 250 bar
Delivery rate: 1.6 m³/min
Electrical connection: 380 V, 0.45 kW
Hsdsbp Dpkopfx Aqtjr
Space requirement: 200 x 250 x 350 mm
Listing
Ennepetal
1,084 km
Hydraulic Pumps Unit
ACONA160l - Sofort einsatzbereit
Call
Year of construction: 2003, condition: used, tank capacity 160 l
feed pressure 160 bar
Hsdpon Tvg Eofx Aqtor
weight / kg
Listing
Deventer
977 km
Standard-SZM
MANTGX 18.480 Tractor with Hydraulic unit
Call
Condition: good (used), mileage: 831,107 km, power: 353 kW (479.95 HP), first registration: 02/2015, fuel type: diesel, axle configuration: 4x2, fuel: diesel, brakes: retarder, color: silver, driver cabin: sleeper cab, gearing type: automatic, number of gears: 16, emission class: euro6, suspension: air, Year of construction: 2015, Equipment: ABS, AdBlue, air conditioning, central locking, cruise control, electric window regulation, fridge, navigation system, power mirror, retarder, = Additional options and equipment =
- Aluminium fuel tank
- Tipping hydraulics
- Air suspension
- Radio/CD player
- Sleeper cab
- Sun visor
- Power take-off (PTO)
- Power take-off (PTO)
= Remarks =
MAN TGX 18.480 TRACTOR, EURO 6, RETARDER, ALU TANK, HYDRAULIC UNIT, GERMAN REGISTRATION, VALID INSPECTION UNTIL 02-2026, TRUCK IS IN EXCELLENT CONDITION. MORE INFORMATION ON REQUEST.
= Further information =
Technical information
Number of cylinders: 6
Axle configuration
Suspension: Air suspension
Front axle: Steered; Left tire tread: 40%; Right tire tread: 40%
Rear axle: Twin tires; Left inner tire tread: 60%; Left outer tire tread: 60%; Right inner tire tread: 60%; Right outer tire tread: 60%; Final drive: single reduction
Weights
Unladen weight: 7,821 kg
Hjdpfx Aqowwthcotsr
Payload: 10,179 kg
Gross vehicle weight (GVW): 18,000 kg
Condition
Technical condition: good
Visual condition: good
Further information
Please contact Gerrit Haverhoek or Piet Haverhoek for more information.
Listing
Hochdorf
1,342 km
Temperature Cooling Unit (TCU)
SingleEasitemp 150/6/45 (Easi150.B)
Call
Condition: new, *Technical standard specification:
Unit type: 6/150
Heating capacity: 6 kW
Cooling capacity: 45 kW
(Performance data at 80°C flow temperature and 15°C cooling water temperature and a pressure difference between cooling water inlet and outlet of at least 2 bar)
Medium: water up to 150°C
Maximum external volume: 9 ltr at 150°C
*Functional equipment:
- Cooling and filling controlled via solenoid valve
- Automatic filling via cooling water
- Level monitoring by magnetic float switch
- Dirt filter in return flow of circulation and cooling water inflow
- Reversing circuit for leakage stop operation (usable up to system closing temp.)
- Ball valve in flow & return
- Automatic temperature-dependent system closure
- Filling time monitoring and aquatimer
- Adjustable pump overrun
- Adjustable temperature alarm
- Options: Interface cable
- Regulation and control unit SBCmini, with relay for common alarm, 230V, on rear of controller on terminal block
- Heating control SSR
- Control box IP54
- Interface 20mA TTY; pin assignment Arburg
- Cekon plug 16A
- Corrosion-resistant components (VA,MS)
- Unit mounted on castors, two of them steerable with brake
- Additional temperature fuse for safe shutdown of the heating on heating contactor
- Bypass between flow and return with reduced cross-section
Hsdsfnvwqepfx Aqtsr
*Pump:
Type: Y2051
Delivery rate (max) 27 ltr/min
Delivery pressure (max) 4.5 bar
Motor power 0.5 kW
Type of submersible pump / peripheral impeller
*Dimensions/Weights/Colours
Dimensions L/W/H: 600 mm x 240 mm x 493 mm (without connection)
Weight: approx. 43 kg
Colour: Housing: RAL 7035 light grey
Front door: RAL 5015 sky blue
*Connections:
Circulation medium socket G1/2"
cooling water socket G3/8"
*This unit conforms to the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Listing
Hochdorf
1,342 km
Temperatre Cooling Unit (TCU)
SingleOil Advanced D2
Call
Condition: new, *TECHNICAL SPECIFICATION:
Heating capacity: up to 36 kW
Cooling capacity: up to 116 kW
medium: oil up to 350°C
Maximum external volume: 66 ltr at 350°C
max. flow rate: up to 150 l/min
max. delivery pressure: up to 8,0 bar
Motor power: 2.8 or 4 kW
Dimensions LxWxH: 1,414 x 503 x 1,350 mm
(without connections for continuous bypass)
Weight approx. 225-320 kg
Circulation medium connection: Flange DN25 PN16-40 (DIN EN 1092-1), form B1
Hedpfx Aqjg Ey Rfotsr
*HIGHLIGHTS EQUIPMENT:
-Regulation and control unit Smart Controller (7" Touch-Displ)
-Heating control via solid-state relay
-Control box IP54
-Cooling controlled via solenoid valve
-Flow measurement using the differential pressure principle
-Bypass between flow and return with reduced cross-section
-Level monitoring by means of magnetic float switch
-flow monitoring by recording the heating rod surface temperature and the flow rate
-dirt filter in the cooling water supply and in the return of the circulation system
-monitoring of the flow temperature by electronic safety temperature limiter
-external oil filler neck
-Dilo fittings on internal piping connections (except pump connections)
-at 350°C: continuous bypass, including bellows valves
-Connection for nitrogen blanketing with pressure gauge and safety valve 0.5 bar at 350°C (option)
Visit our website for more details or for other performance classes.
*Unit is compliant with European Directives. Other directives and standards are only complied with if stated in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be stated in quotations or order confirmations.
Listing
Hochdorf
1,342 km
Temperature Cooling Unit (TCU)
SingleCompact WK3-160-9-50 (IM160F)
Call
Condition: new, *Technical standard specification:
Heating capacity: 9 kW
Cooling capacity: 50 kW
medium: water up to 160°C
Max. external volume: 16 ltr at 160°C
max. Flow rate 57l/min
max. Delivery pressure 6,0 bar
Dimension L x W x H 780 x 305 x 705 mm
Weight approx. 80 kg
HIGHLIGHTS EQUIPMENT:
- Smart Controller Plus 7" touch / 4.0 capable
- Flow measurement, adjustable flow alarms
- Return temperature display
- Frequency converter for pump speed control with automatic mode for energy-optimised operation, or adjustable flow rate (in the operating range of the temperature control system)
- Electronic pressure transducer in the flow
- Interface via 9-pin D-Sub connector 20mA/TTY
Hodpfx Aqoftm Hrjtor
- Connection for external temperature sensor PT 100 for measuring and displaying the mould temperature
- Continuous bypass of the heat exchanger with a 3-way valve to reduce deposits in the heat exchangers
- More powerful pump, hydraulic parts made of VA, magnetically coupled
- Tool emptying by suction
- Booster pump for tool filling at high temperatures
- Filling via cooling water can be switched to separate filling
- SSR for heating control
- IP54 splash water protection
Visit our website for more details or for other performance classes.
*This unit is compliant with European Directives. Other directives and standards are only complied with if stated in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Listing
Hochdorf
1,342 km
Temperatre Cooling Unit (TCU)
SingleEasitemp 95/6/45 (Easi95.A)
Call
Condition: new, *Technical Specification:
device type: 6/95
heating capacity: 6 kW
cooling capacity: 45 kW
Medium: water up to 95°C
maximum external volume: 50 ltr at 95°C
*Equipment hydraulic:
- Cooling and filling controlled by solenoid valve
- Automatic from cooling water or manual filling (at filling nozzle/option)
- Level monitoring by magnet float-switch
- Dirt trap in from process line of circulating system and cooling water inlet
- Pump reversing for leak-stop operation
- Manual mould draining via leak-stop operation and venting by tap at backside of unit
- Filling time monitoring and aquatimer
- Cool down mode (temperature adjustable)
- Adjustable temperature alarm
- Options: filling nozzle, interface cable, mechanical flow metering
*Equipment electrical:
- Controller SBCmini, with relay for collective alarm
230V switchable, on the back of controller on terminal
- Heating control by SSR
- Control cabinet IP54
- Interface 20mA TTY; pinning Arburg
- Cekon plug 16A
*General equipment:
- Corrosion resistant components (stainless stell, brass)
- Heating rod made of Incoloy
- Unit mounted on rolls, two pieces steerable with break
- Additional temperature fuse for safe heating switch-off
by contactor
*Cooling:
Power: 45 kW (stainless steel plate heat exchanger)
Cooling water connection: Socket G3/8" IG
(Performance data at 80°C flow and 15°C cooling water temperature and a pressure difference between cooling water inlet and outlet of 3 bar)
*Pump:
Type: T401
Output rate (max): 40 ltr/min
Hodefnvvispfx Aqtor
Pressure (max): 3,8 bar
Motor capacity: 0,5 kW
Construction: submersible pump / peripheral wheel
*Dimensions/Weights/Colours
Dimensions L/W/H: 514 mm x 238 mm x 493 mm (w/o conne.)
Weight: approx. 30 kg
Colour: Case: RAL 7035 light grey
Front door: RAL 5015 sky blue
*Connections:
Circulating medium int. thread G1/2"
Cooling water int. thread G3/8"
Filling (option)
*This unit complies to the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment; customer requests deviating from the standard will be indicated in offers or order confirmations.
Listing
Hochdorf
1,342 km
Temperature Cooling Unit (TCU)
SingleVariotherm ATT H2-200-48
Call
Condition: new, *TECHNICAL SPECIFICATION:
Heating power hot circuit: 48 kW
heating capacity cold circuit: 12 kW
cooling capacity hot circuit: 42 kW
cooling capacity cold circuit: 270 kW
medium: water up to 200°C
Max. external volume: 10 ltr at 200°C
Max. flow rate: up to 200 l/min
max. delivery pressure: up to 6,5 bar
motor power: 5,5 kW
Dimension LxWxH: 1.395 x 753 x 1.180 mm
Weight approx. 580 kg
Hodpfx Ajg Ey Ufsqtjr
*HIGHLIGHTS EQUIPMENT:
-regulation and control via SPS with touch screen
-heating via stainless steel tubular heating elements made of Incolloy
-Heating control via solid-state relay
-control box IP54 externally ventilated2
-electrical wiring on terminal blocks
-pot. free input for signal for cold/warm changeover (front door)
- Pot.-free contact for collective alarm on 3-pin plug-in connector (front door) (front door)
-temperature control unit with heating and cooling circuit, for connection of a valve station for quick changeover between hot and cold circuit
-temperature controlled feed of the return water
-level monitoring with automatic level compensation
-dirt filter in the cooling water supply and in the return of the circulation system
-Separate automatic filling with strainer
-Flow measurement in differential pressure principle in both circuits
-monitoring of the heating rod surface by temperature sensors
-System pressure control, necessary compressed air connection: 6 to 8 bar
-booster pump type DS 360 for water make-up
-corrosion-resistant components (VA, MS)
-unit mounted on rollers and ready for connection
*OPTIONS:
-System EcoTemp for intermittent operation
-connection for ext temperature sensor PT100 or type J/K
-Remote touch screen with 15 m cable
Visit our website for more details or for other performance classes.
*This device is compliant with the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Listing
Hochdorf
1,342 km
Temperature Cooling Unit (TCU)
SingleWater Advanced WP7
Call
Condition: new, *TECHNICAL SPECIFICATION:
Heating capacity: up to 54 kW
Cooling capacity: up to 300 kW
Hedpfx Aqog Ey T Ester
medium: water up to 200°C
Max. external volume: 43 ltr at 200°C
max. Flow rate: max. 230 l/min
max. delivery pressure: up to 8.3 bar
Motor power: up to 3 kW
Dimensions LxWxH: 1,460 x 525 x 1,200 mm
Weight approx. 330kg
Circulation medium connection: flange DN40 (DIN EN 1092-1), form B1
*HIGHLIGHTS EQUIPMENT:
-Control and regulation Smart Controller (7" touch display)
-Heating control via solid-state relay
-Control box IP54, externally ventilated
-Expansion tank, heater and piping stainless steel
-Heating via stainless steel tubular heating elements made of Incolloy
-Dirt trap (circulation)
-Unit ready for connection and mounted on castors, 2 of them steerable and with brake
-Cooling and filling controlled by solenoid valve
-configurable automatic filling via KW inflow or separate connection (factory-supplied via cooling water inflow)
-flow measurement by differential pressure principle
-Level monitoring by magnetic float switch
-automatic temperature-dependent system closure (not with WP7-90)
-flow monitoring by recording the flow rate
-Bypass between flow and return with reduced cross-section
-dirty filter in the cooling water inflow, filling and return of the circulation system
-Continuous bypass of the heat exchanger via 3-way motorised control valve (WP7-180/200)
-System pressure monitoring via pressure transmitter in the AD tank (WP7-150/180/200)
-Pressure booster pump for system filling (WP7-180/200, otherwise optional)
-Safety temperature limiter (STB) in the heater and flow (WP7-200)
-Pressure gauge in the supply line on the back of the unit
-heat-insulated circulation circuit (WP7-150/180/200)
Visit our website for more details or for other performance classes.
*This unit is compliant with the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Listing
Hochdorf
1,342 km
Temperature Cooling Unit (TCU)/ Chiller
SingleChill Plus Testing CHT-130
Call
Condition: new, *TECHNICAL SPECIFICATION:
Heating capacity: up to 36 kW per consumer circuit
Cooling capacity: up to 30 kW per consumer circuit at -30°C
Load circuits: 1 or 2 as standard
Temperature range: - 45°C to +130°C
Medium: water / glycol mixture
Dimensions LxWxH (without connections) :
1-circuit: 1950 x 1280 x 1725 mm
2-circuit: 2150 x 1640 x 1725 mm
Weight:
1-circuit: approx. 1300kg
2-circuit: approx. 1500kg
*HIGHLIGHTS EQUIPMENT:
-Controls: Temperature control (standard)
-Control via SPS with touch screen
-Analogue and digital interfaces
-Internal 2-circuit pump system (INFO: Ensures performance values even at low flow rates)
-Heating control via solid-state relay (SSR)
Hjdpfx Aqjg Ezarjter
-Flow measurement in the internal circuit for flow monitoring (INFO: If the water/glycol mixture is incorrect, the system automatically warns and switches off in the next step)
-Pressure-controlled cooling water regulator (INFO: Much more accurate than temperature controls)
Stainless steel tank, corrosion-resistant components (stainless steel/non-ferrous metal) (non-ferrous metal-free optional)
All medium-carrying components and piping insulated for low-temperature application
-Water-cooled condenser (air-cooled on request).
*OPTIONS:
-flow rate control: up to 100l/min, >4 l/min +/- 5% of measured value
-Pressure control: 0.5 to 4.5 bar (control range)
-compressed air monitoring
-test piece emptying by means of compressed air
- Cooling water monitoring
-Limitation of inlet pressure
-Other special options available on request and after technical inspection
Visit our website for more details or for other performance classes.
*This unit conforms to the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Listing
Cantabria
1,160 km
Control unit HYDRAULIC VALVE
Bosch0810090191
Call
Condition: used, functionality: fully functional, HYDRAULIC VALVE
Hjdpfsxzfp Rox Aqtsr
All our items have been inspected by the technical department.
Listing
Cantabria
1,160 km
Control unit HYDRAULIC VALVE
Mannesmann Rexroth4WE6D53-AG24NZ4
Call
Condition: used, functionality: fully functional, HYDRAULIC VALVE
All our items have been inspected by the technical department.
Hjdpfx Ajxzpwrsqtsr
Listing
Borken
1,027 km
Refrigeration system 11kW cooling unit
RehslerTW HL4006D
Call
Condition: good (used), Rehsler TW HL4006D Refrigeration System
Voltage: 400 V
Rated power: 11 kW
Current consumption: 18 A
Protection class: IP54
Operating pressure: 10 bar
Minimum ambient temperature: 5°C
Maximum ambient temperature: 43°C
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items – new and used – in our shop!
International shipping costs on request!
Hedpexg Hmnefx Aqtjr
Listing
Borken
1,027 km
Control cabinet cooling unit
RittalPS 4806
Call
Condition: good (used), Rittal PS 4806 Baying Enclosure
Product Description
Hodpfx Aqotzbxzstsr
PS 4000 Baying System
Manufacturer: Rittal
Baying System: PS 4000
Model: PS 4806
Enclosure frame: 1.5 mm sheet steel
Roof: 1.5 mm sheet steel
Door: 2.0 mm sheet steel
Rear panel: 1.5 mm sheet steel
Mounting plate: 3.0 mm zinc-coated sheet steel
Base plates: 1.5 mm sheet steel
Enclosure frame: Dip-coated
Door, roof, and rear panel: Dip-coated
Exteriorly powder-coated, textured paint
Color: RAL 7035
4 eyebolts
Sheet steel wiring diagram pocket 4118000
Large 19" swing frame 44 U
Plinth system as a stable enclosure base
Enclosure cooling unit SK 3296100
Dimensions (HxWxD)
2500 x 800 x 600 mm
Find more items in other sizes – new and used – in our shop!
International shipping costs upon request!
Listing
Borken
1,027 km
Condensing unit cooling unit
MyRefMY-ZB26-TFD
Call
Condition: excellent (used), MyRef MY-ZB26-TFD refrigeration unit
MyRef MY-ZB26-TFD condensing unit suitable for refrigeration applications
Hsdpevtl T Dsfx Aqtjr
Typical applications are
Freezer cabinets in supermarkets and minimarkets
cold stores
Beer cellars
Milk cooling systems
Standard equipment
Copeland Scroll M compressor
ZB series with sound insulation hood
Oil sump heater
Liquid receiver with burst protection
Filter dryer
Sight glass visible from outside
Ball shut-off valves
Component-tested combined HP/ND safety pressure switch
Electrical equipment: IP 55 switch box, compressor contactor, DIN rail mounting
Condenser is integrated and protected in the housing
Condenser fins coated with epoxy resin phenol (gold paint*)
High-quality housing: solid in 1.5 mm galvanized and powder-coated sheet steel, base plate and feet in 2 mm sheet steel
Frame construction with individually removable panels; all screws and components can be accessed from the front with minimal effort
Blind rivet nuts with carriage bolts for secure, durable fastening without rust problems Pressure-controlled speed regulator with EMC filter
Space-saving installation of several units next to each other possible; required mounting distance 25 mm
Type: MyRef -ZB26-TFD
Copeland Scroll
Condensing unit Type: MyRef -ZB26-TFD
Built-in compressor type: ZB19-KQE-TFD-525
Sound pressure level: 39 dbA-10 m
Collector volume: 6 liters
Air volume: 4500m³/h
Cooling capacity: 9 kW
Voltage: 400V,3PH,50Hz
Power consumption: 8.9 A
Dimensions:
HxWxD 715 x 1120 x 450 mm
Weight: 102 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You can find more items - new and used - in our store!
International shipping costs on request!
Listing
Borken
1,027 km
Refrigeration machine Cooling unit
IKSIPE 051
Call
Condition: good (used), IKS cooling unit 20.4 kW
Manufacturer: IKS
Series: IPE 051
Refrigerant: R407 C
Quantity: 3.1 kg
Max. pressure: 27.6 bar
Temp. min/max: -10/55C
Cooling capacity: 20.4 kW
Compressor power consumption: 5.6 kW
Temperature stability: 2 K
Tank capacity: 110 liters
Water connections: 1 1/4" AG inch
Cooling air volume: 5370 m3/h
Mains connection: 400/50/3 V/Hz/Ph
Net weight: 300 kg
Dimensions: LxWxH 980 x 800 x 1785 mm
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You can find more items – new and used – in our shop!
International shipping costs on request!
Hsdpfx Aqjxbfknoter
Listing
Borken
1,027 km
Laser cooling cooling unit
RofinWKH/W-13000-W-MC-SON-3-D
Call
Condition: like new (used), Rofin RoHS WKH/W-13000-W-MC-SON-3-D Laser Cooling System
Laser Cooling System
Hedpfx Aqeq Hdw Uotjr
Rofin RoHS WKH/W-13000-W-MC-SON-3-D
Rofin Controller LasCon WaC 2
Störk Tronic Thermostatic Controller
Buschjost Solenoid Valves
400 Volts
Unused stock
Financing through our bank is also possible.
komplett-konzept.leasingo.de
More new and used items available in our shop!
International shipping costs on request!
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
1,027 km
HF Welding unit Water cooling
EMAMFA PT2000
Call
Condition: good (used), Year of construction: 2004, EMA high frequency welding unit with cold water chiller
EMA High Frequency Welding Unit MFA
with Thermotec PT2000 water cooling system
Welding unit range 0 - 1000 ° C
MF output: 80A
Frequency MF-Gen.: 10 KHz
Mains connection: 380V
106 A
foot pedal
Water cooling, cold water chiller
Thermotec PT2000
Dimensions approx. L1500x W730x H1900mm
Volume 1730 Ltr.
Year: 2004
The drip pan is not included in the scope of delivery.
Financing through our bank is also possible.
komplett-konzept.leasingo.de
More articles - new and used - can be found in our shop!
International shipping costs on request!
Hedpfjd Tv H Dex Aqter
Listing
Borken
1,027 km
Hydraulic unit Pump unit
KraussMaffeiSPA 12/25 RP
Call
Condition: good (used), Krauss-Maffei SPA 12/25 RP
Manufacturer: Krauss-Maffei
Type: SPA 12/25 RP
Type: Hydraulic power unit
Complete factory closing,
wide range of storage platforms, pallet racks, shelf racks, paternosters.
High quality industrial machines, lathes, grinding machines, hand machines
Further articles - new and used - you will find in our shop!
International shipping costs on request!
Hedpfx Aehvml Dsqter
Listing
Dorsten
1,046 km
Hydraulic Pumps Unit
MANNESMANN REXROTHHydraulik
Call
Condition: used, feed pressure . bar
liter capacity . l
power capacity . kW
total power requirement . kW
weight of the machine ca. . t
dimensions of the machine ca. . m
The tech. Data are manufacturer or operator information and therefore non-
binding. We reserve the right to prior sale; Our terms and conditions of sale
apply exclusively.
About us More
than 400 of our own machines in stock
Over 15,000 m² of storage space, 70 t crane capacity
More than 10,000 items and accessories for your workshop
If you are interested in selling machines, production lines, or your business,
please contact us. You can find further offers on our website. Tours are
possible by appointment.
Hedpfx Asyv Ixgjqtsr
We look forward to your visit.
Your Markus Hirsch Team
Listing
Dorsten
1,046 km
Hydraulic Pumps Unit
MANNESMANN REXROTHHydraulik
Call
Condition: used, feed pressure . bar
liter capacity . l
power capacity . kW
total power requirement . kW
weight of the machine ca. . t
dimensions of the machine ca. . m
The tech. Data are manufacturer or operator information and therefore non-
binding. We reserve the right to prior sale; Our terms and conditions of sale
apply exclusively.
About us More
than 400 of our own machines in stock
Over 15,000 m² of storage space, 70 t crane capacity
More than 10,000 items and accessories for your workshop
Hedpfsyv Iunox Aqtor
If you are interested in selling machines, production lines, or your business,
please contact us. You can find further offers on our website. Tours are
possible by appointment.
We look forward to your visit.
Your Markus Hirsch Team
We make it easier for you to find: "hydraulic cooling unit"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you





























































































































































