CTS Temperature Test Chamber T-70/600, temperature range -70°C to 180°C, 600 liters, 041133CTS
Temperaturprüfschrank
CTS Temperature Test Chamber T-70/600, temperature range -70°C to 180°C, 600 liters, 041133
CTS
Temperaturprüfschrank
Condition
Used
Location
Borken 

Basic data
- Machine type:
- CTS Temperature Test Chamber T-70/600, temperature range -70°C to 180°C, 600 liters, 041133
- Manufacturer:
- CTS
- Model:
- Temperaturprüfschrank
- Condition:
- used
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A22270132
- Reference number:
- 23070
- Update:
- 15.10.2026
Description
CTS
Type: T-70/600
CTS Temperature Test Chamber, Water-Cooled
Technical Performance Data:
Temperature Operating Range
Temperature range -70°C / +180°C
Cooling rate 3.0 K/min
Heating rate 3.5 K/min
Temperature stability, time-related ≤± 0.3 K
Dimensions:
Test volume: 600 liters
Test chamber dimensions: height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions: height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating Data:
Electrical connection 400 V +6% -10%, 3/N, 50 Hz
Connected load 8.2 kW, 14.2 A
Refrigerant: R404A / R23
Weight: 600 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Gusdpfx Aajziygyjxoh
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Type: T-70/600
CTS Temperature Test Chamber, Water-Cooled
Technical Performance Data:
Temperature Operating Range
Temperature range -70°C / +180°C
Cooling rate 3.0 K/min
Heating rate 3.5 K/min
Temperature stability, time-related ≤± 0.3 K
Dimensions:
Test volume: 600 liters
Test chamber dimensions: height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions: height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating Data:
Electrical connection 400 V +6% -10%, 3/N, 50 Hz
Connected load 8.2 kW, 14.2 A
Refrigerant: R404A / R23
Weight: 600 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Gusdpfx Aajziygyjxoh
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Success:
Your message has been sent.
Listing
Borken
1,034 km
CTS Temperature Test Chamber T-70/600/S Temperature -70°C to 180°C 600 liters
CTSTemperaturprüfschrank
CTSTemperaturprüfschrank
Success:
Your message has been sent.
Listing
Borken
1,034 km
CTS Temperature Test Chamber T-70/600, temperature range -70°C to +180°C, 600 liters
CTSTemperaturprüfschrank
CTSTemperaturprüfschrank
Success:
Your message has been sent.
Listing
Borken
1,034 km
CTS Temperature Test Chamber T-70/600/S Temperature -70°C to 180°C 600 liters
CTSTemperaturprüfschrank
CTSTemperaturprüfschrank
Success:
Your message has been sent.
Listing
Borken
1,034 km
CTS temperature test chamber T-30/950, -30°C to +80°C
CTSTemperaturprüfschrank
CTSTemperaturprüfschrank
Your listing has been deleted successfully
An error has occurred