Used Vötsch Temperature Test Chamber -70°C To +180°C for sale (74,244)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
1,034 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 4,748 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021,
total operating hours: 4748.2 h
For sale is a used temperature test chamber from Weiss Technik. This chamber is used for testing components and materials under various temperature conditions (e.g. cold, heat, aging).
Model designation explanation:
T = Temperature test chamber
1000 = approx. 1000 liters volume
70 = low-temperature range (-70 °C)
e = energy-optimized design
5 = temperature change rate (model series)
Equipment features:
- Stainless steel interior
- Recirculating air fans
- Touch control (WEBSeason)
- Viewing window
- Automatic/manual temperature control
Technical specifications:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rate:
Cooling approx. 6 K/min
Heating approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (H x W x D)
Internal dimensions: approx. 950 x 1100 x 950 mm (H x W x D)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1200 kg
For your peace of mind as a buyer, the following work is carried out on our chambers prior to sale:
1. Functional inspection and replacement of any necessary components
2. New filling with legally compliant refrigerant when required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in technical data and specifications reserved!)
Iaodpfxoy Dd Nqs An Uer
For further questions, please feel free to contact us by phone.
Listing
Borken
1,034 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 5,128 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021
Operating hours: 5018 h
For sale is a used temperature test chamber from Weiss Technik.
This chamber is used to test components and materials under various temperature conditions (e.g., cold, heat, aging).
Meaning of the designation:
T = Temperature test chamber
1000 = approx. 1000 liters volume
70 = low temperature range (-70 °C)
e = energy-optimized design
5 = temperature change rate (series)
Features:
- Stainless steel interior
- Recirculating air fans
- Touch operation (WEBSeason)
- Viewing window
- Automatic / manual temperature control
Technical specifications:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rates:
Cooling: approx. 6 K/min
Heating: approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (H x W x D)
Internal dimensions: approx. 950 x 1100 x 950 mm (H x W x D)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Iodoy Dclwjpfx An Uoar
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1300 kg
For your peace of mind as a buyer, please note the following:
The following procedures are carried out on all chambers prior to sale:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see photos)
(Specifications and data are subject to change and errors reserved!)
If you have any further questions, we will be happy to answer them by phone.
Listing
Borken
1,034 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 5,018 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021
Operating hours: 5018 h
For sale is a used temperature test chamber from Weiss Technik.
The test chamber is used for testing components and materials under various
temperature conditions (e.g., cold, heat, aging).
Designation meaning:
T = Temperature test chamber
1000 = approx. 1000 liters volume
70 = low-temperature range (-70 °C)
e = energy-optimized version
5 = temperature change rate (series)
Features:
- Stainless steel interior
- Recirculation fans
- Touch operation (WEBSeason)
- Viewing window
- Temperature control (automatic/manual)
Technical specifications:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rate:
Cooling: approx. 6 K/min
Heating: approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (H x W x D)
Internal dimensions: approx. 950 x 1100 x 950 mm (H x W x D)
Connection: 400 V / 50 Hz / 3-phase
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1300 kg
For your peace of mind as the buyer, the following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Iajdpfxjy Dclqe An Usr
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in technical specifications!)
We are happy to answer any further questions by phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
1,034 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 5,128 h, condition: excellent (used), Weiss Temperature Test Chamber TempEvent T/1000/70e/5, water-cooled, 1000 liters, year of manufacture 2021, operating hours: 5128 h
For sale is a used temperature test chamber from Weiss Technik. This chamber is designed for testing components and materials under various temperature conditions (e.g. cold, heat, aging).
Model designation explanation:
T = Temperature test chamber
1000 = approx. 1000 liters capacity
70 = low temperature range (-70 °C)
e = energy-optimized version
5 = temperature change rate (series)
Equipment features:
- Stainless steel interior
- Recirculating air fans
- Touch operation (WEBSeason)
- Viewing window
- Automatic/manual temperature control
Technical data:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rate:
Cooling: approx. 6 K/min
Heating: approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (HxWxD)
Internal dimensions: approx. 950 x 1100 x 950 mm (HxWxD)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1200 kg
For your security as a buyer, please note the following information:
The following steps are performed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
Iasdpfxjy Dck Ts An Ujr
4. After successful checking, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see pictures)
(Specifications and technical details subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing
Borken
1,034 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 4,748 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021,
running hours: 4748 h
Offered for sale is a used temperature test chamber from Weiss Technik. The chamber is used for testing components and materials under various temperature conditions (e.g., cold, heat, aging).
Explanation of the model designation:
T = temperature test chamber
1000 = approx. 1000 liter volume
70 = low temperature range (-70 °C)
e = energy-optimized version
5 = temperature change rate (series)
Equipment features:
- Stainless steel interior
Iasdsy Dciijpfx An Uor
- Recirculation air fans
- Touch control (WEBSeason)
- Viewing window
- Automatic / manual temperature control
Technical data:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rate:
Cooling: approx. 6 K/min
Heating: approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (HxWxD)
Internal dimensions: approx. 950 x 1100 x 950 mm (HxWxD)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerants: R449A / R23
Weight: approx. 1200 kg
Important safety information for buyers:
The following processes are carried out on the chambers we offer before delivery:
1. Function check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data subject to change and errors excepted!)
We are happy to answer any further questions by phone.
Listing
Borken
1,034 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70/5 1000 Liter
Call
Year of construction: 2020, operating hours: 6,126 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70/5,
water-cooled, 1000 liters, year of manufacture 2020,
total operating hours: 6,126 h.
Description:
Iedpfx Anjyxm Ulo Uoar
For sale is a high-quality climate test chamber from Vötsch Industrietechnik
(Weiss Technik), model TempEvent T/1000/70/5.
This unit is designed for the simulation of temperature conditions and is ideally suited for:
- Material testing
- Electronics inspections
- Environmental and aging tests
- Quality and endurance tests
The chamber can achieve both very low temperatures down to approx. -70 °C and high temperatures up to +180 °C,
and can change temperatures at a defined rate (temperature ramps).
Precise control allows for reproducible testing conditions.
Operation is user-friendly via an integrated touch panel.
Features:
- Fast temperature changes (up to 5 K/min)
- Even temperature distribution in the test space
- Water-cooled system
- Industrial standard – robust construction
- Maintenance indicator and operating hours counter included
Technical Data:
Model: TempEvent T/1000/70/5
Temperature range: approx. -70 °C to +180 °C
Temperature change speed: up to 5 K/min
High precision & stability:
Temporal temperature deviation: ±0.1 to ±0.5 K
→ very stable temperature over time
Spatial deviation: ±0.5 to ±1.0 K
Temperature gradient: ≤ 2.0 K
This makes the chamber ideal for demanding testing processes
with high repeat accuracy.
Test chamber dimensions: approx. 950 × 1100 × 950 mm (W × H × D)
External dimensions: approx. 2000 × 1415 × 2030 mm (W × H × D)
Side port: 50 cm / 125 cm
Electrical data:
400 V / 3~ / 50 Hz
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerants:
R449A (approx. 2.9 kg)
R23 (approx. 1.3 kg)
Weight: approx. 1,200 kg
For your security as a buyer, please note the following:
The following checks are carried out on all our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications subject to change and errors excepted!)
Further questions can be answered for you by phone.
Listing
Borken
1,034 km
Temperature test chamber -70°C to +180°C
VötschVTS 7018-5 190 Liter
Call
Condition: excellent (used), Vötsch
Model: VTS 7018-5
Iajdpfx Aowq Iymen Ujr
Water-cooled Temperature Test Chamber
System retrofitted with R-452A
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature change rate cooling: 7.5 K/min
Temperature change rate heating: 7.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated power: 10.0 kW, Rated current: 21 A
Main fuse (on-site): 32 A slow-blow
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side port: 50 mm / 125 mm
Chamber is water-cooled
Refrigerants: R-452A and R 23
Weight approx. 460 kg
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, new charging with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Technical data may be subject to change or error!)
If you have any further questions, we will be happy to answer them by phone.
Listing
Borken
1,034 km
Temperature test chamber -70°C to +180°C
VötschVT 7021
Call
Condition: excellent (used), Heraeus Vötsch
Type: VT 7021
Air-cooled temperature test chamber
1 port, nominal width 80 mm,
Test chamber volume: 210 liters
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (heating): 2.5 K/min
Temperature change rate (cooling): 2.5 K/min
Max. heat compensation: 800 W
Test chamber dimensions: Width 560 mm, Depth 570 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1250 mm, Height 1640 mm
Electrical connection: 1/NPE AC 230 V ± 10% 50 Hz
Rated power approx. 1.8 kW, rated current 12 A
Refrigerant: R404A and R23
Weight: 355 kg
For your safety as a buyer, please note the following information!
The following procedures are performed on the chambers we offer, in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Subject to technical modifications and errors in the details!)
Iedpfxjwylv Dj An Uear
For further questions, please feel free to contact us by phone.
Listing
Borken
1,027 km
Temperature shock test chamber -70-220°C
VötschVT 7012 S2
Call
Year of construction: 2000, operating hours: 104,382 h, condition: excellent (used), Vötsch Shock Test Chamber VT 7012 S2
System for extreme temperature cycling
Temperature shock testing is used to test the resistance of components, devices, and other products to rapid changes in ambient temperature.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
These cyclical stresses and the accelerated aging caused by temperature changes reveal weaknesses in the test specimen.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the car
Cart load capacity 50 kg for VT3 7012 S2
All-around grilles in the car secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
Hot chamber can be used as a temperature storage unit, cold chamber as a temperature exchange unit
Minimal energy consumption
No compressed air required
Manufacturer: Vötsch
Type: VT 7012 S2
Type: Temperature shock test chamber
Test chamber volume: 120 l
Nominal voltage: 400 V
Nominal power: 10 kW
Nominal current: 25 A
Refrigerant: R452A
Cooling unit: Water-cooled
Shock cooling (nitrogen cooling) via customer-supplied nitrogen
External dimensions
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class
Device: IP 42
Operating panel: IP 20
Control cabinet: IP 54
Temperature test parameters for single-chamber operation |
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class ...Temperatur Temperature range
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: ±2 K
in steady state
Temperature deviation over space: ±2 K
in steady state in the car
Heating rate, hot chamber: 11 K/min
Cooling rate, cold chamber: K/min
Heating rate, cold chamber: 2 K/min
Cooling rate, hot chamber: K/min
Observation window: 355 x 355 mm
Pipe opening: 67 mm
Year of manufacture: 2000
Operating hours: 104,382
Weight: 1000 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Iedpjx Exmtefx An Usar
Further items – new and used – can be found in our shop! International shipping costs on request!
Listing
Borken
1,034 km
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
Ijdpfsv N Hc Ejx An Uoar
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Climate test chamber Temp. -70 to 180°C
Weiss explosionsgeschütztWK-600/70 (I)-(II) 2 G EEx
Call
Condition: excellent (used), Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss climate chamber water-cooled
(test room explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST ROOM
Technical data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Iedpfxev Ewy Hs An Uear
Height 1995 mm, width 1000 mm, depth 1660 mm
Test room capacity: approx. 600 liters
Cold / heat operation -70 to 180°C
Climate operation 10 – 95°C
Humidity 10...98% r. H.
Temperature change per time
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
On-site fuse: 32 A slow-blow
Permissible test item weight
Total load of the grate supports 80 kg
Test room floor 80 kg, grate insert 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(The air conditioning system's evaporator has been replaced)
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Climatic test chamber -70°C to +180°C
VötschVCS 7034-5 - 335 Liter
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation in time K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Isdpfx Asuxq T Djn Ujar
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Environmental test chamber -70°C - +180°C Humidity
ThermotronSM-8-8200
Call
Condition: excellent (used), Here we offer you Thermotron environmental test chamber.
Thermotron Environmental Test Chamber Water Cooled
Working volume: 227 liters
Temperature uniformity: All models 0.7°C
Temperature range: -70°C to + 180°C
Temperature control tolerance: All models 0.3°C
Shipping weight: approx 400 kg
Internal dimensions width 610 mm x depth 610 mm x height 610 mm
Outer dimensions width 890 mm x depth 1240 mm x height 1850 mm
Humidity range: All models 10% to 98% RH
Humidity control: All models 2.5% RH
Heating capacity in minutes -65º to 71ºC: 17
Heating power in minutes -65º to 180ºC: 43
Heating power in minutes -40º to 85ºC: 16
Electrical requirements in full load amplifiers 230/3/60: 19
Electrical requirements in full load amplifiers 230/1/60: 25
Electrical requirements in full power amplifiers 220/1/50: 27
Cooling capacity in minutes 85º to -40ºC: 32
Cooling capacity in minutes 71º to -65ºC: 54
Cooling capacity in minutes 180º to -65ºC: 72
Iaedpfxjmhfr Io An Uor
Compressor size: (2) -2 Hp
Operating voltage: 400V 16.7 A
Type: SM-8-8200
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Győr
1,926 km
Temperature test chamber -72°C to +180°C
VötschVTS 7060-5 600 Liter
Call
Year of construction: 2016, operating hours: 9,195 h, condition: excellent (used), Vötsch temperature test chamber, water-cooled
Here we offer you a Vötsch temperature test chamber.
Vötsch 7060-5 water-cooled chamber
Test chamber dimensions: Height: 950 mm, width: 800 mm, depth: 800 mm
External dimensions: Height 1995 mm, width: 1090 mm, depth: 1960 mm
Test chamber capacity: approx. 600 liters
Year of construction: 2016
Operational hours: 9195
Entry ports:
R1: NW 125 mm
L1: NW 50 mm
Iasdpfxjt Txtto An Ujr
Data for temperature tests:
Temperature range: -72°C to +180°C
Temperature deviation in time in the center of the usable space ± 0.1 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 2.0 K
Temperature change rate
Heating 6.0 K/min
Cooling 6.0 K/min
Heat compensation at 20°C max. 5000 W
Heat compensation at -20°C max. 5000 W
Electrical connection:
Rated voltage: 3/NPE AC 400V ±10% 50Hz
Rated power: 13,0 kW Rated current: 23.0 A
Refrigerant: R-404A and R-23
Weight (approx.): 650 kg
The following information is for your safety as a buyer!
1. The chamber works perfectly.
2. No components have to be replaced.
3. Refrigerant is filled with legally compliant.
Condition: used (excellent)
(Changes and errors in the technical data, specifications are reserved!)
Listing
Győr
1,926 km
Temperature test chamber -72°C to +180°C
VötschVTS 7060-5 600 Liter
Call
Year of construction: 2016, operating hours: 14,242 h, condition: excellent (used), Vötsch temperature test chamber, water-cooled
Here we offer you a Vötsch temperature test chamber.
Vötsch 7060-5 water-cooled chanber
Test chamber dimensions: Height: 950 mm, width: 800 mm, depth: 800 mm
External dimensions: Height 1995 mm, width: 1090 mm, depth: 1960 mm
Test chamber capacity: approx. 600 liters
Year of construction: 2016
Operational hours: 14 242
Entry ports:
R1: NW 125 mm
L1: NW 50 mm
Data for temperature tests:
Temperature range: -72°C to +180°C
Isdpfx Anot Txqro Usar
Temperature deviation in time in the center of the usable space ± 0.1 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 2.0 K
Temperature change rate
Heating 6.0 K/min
Cooling 6.0 K/min
Heat compensation at 20°C max. 5000 W
Heat compensation at -20°C max. 5000 W
Electrical connection:
Rated voltage: 3/NPE AC 400V ±10% 50Hz
Rated power: 13,0 kW Rated current: 23.0 A
Refrigerant: R-404A and R-23
Weight (approx.): 650 kg
The following information is for your safety as a buyer!
1. The chamber works perfectly.
2. No components have to be replaced.
3. Refrigerant is filled with legally compliant.
Condition: used (excellent)
(Changes and errors in the technical data, specifications are reserved!)
Listing
Kölleda
1,342 km
Temperature chamber - 70°C to 180°C
WEISSWT11-270/70/10
Call
Year of construction: 2001, condition: ready for operation (used), functionality: fully functional, machine/vehicle number: 58226018400020, Weiss Temperature Chamber
Type: WT11-270/70/10
Section No.: 58226018400020
Control: Simcon/32-NET Version: 00.1902
Ports: Left (2x) NW 50 mm, Right (3x) NW 125 mm
Temperature Range: -70°C to 180°C
Test Chamber Volume: 270 liters
Door with window, interior lighting
Water-cooled temperature chamber
Compressed air dryer type: ZANDER
Temperature change rate cooling: 10 K/min
Temperature change rate heating: 10.0 K/min
Temperature deviation over time ± 0.1 to ± 0.5 K
Temperature homogeneity over space ± 0.5 to ± 2.0 K
Test Chamber Dimensions: Width 580 mm x Depth 615 mm x Height 750 mm
Housing dimensions: Width 895 mm x Depth 2080 mm x Height 1950 mm
Voltage: 3/N/PE AC 400V±10% 50Hz
Iasdpfxjv T Tnco An Uor
Rated power 14 kW, Rated current 26 A
Refrigerant: R-404A/R-23
Listing
Borken
1,034 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch temperature test chamber water cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ±0,1 to ±0,5 K
Temperature deviation in time ±0.5 to ±2.0 K
Temperature change rate cooling 7.5 K/min
Temperature change rate heating 7.5 K/min
Heat compensation +20°C 3000 W
Heat compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 450 mm Height 750 mm
Outer dimensions: Width 870 mm Depth 1280 mm Height 1575 mm
Observation window:
Width 300 mm x height 540 mm
Test chamber volume 190 litres
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50Hz
Rated power: 10.5 kW Rated current: 22 A
Fuse, on-site: 32 A slow-blow
Sound level at 1m distance (free field measurement) < 69dB (A)
lateral feed-through 50 cm / 125 cm
Cabinet is water cooled
Refrigerant: R 404A and R 23
Weight approx. 460 kg
Iodpshh H Hiofx An Uear
Type: VTS 7018-5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. function check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer gladly on the phone for you.
Listing
Borken
1,034 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch Type: VTS 7018-5 Heraeus Vötsch Temperature Test Chamber, Water-Cooled Temperature range: -70°C to +180°C Temporal temperature deviation: ± 0.1 to ± 0.5 K Spatial temperature deviation: ± 0.5 to ± 2.0 K Temperature change rate (cooling): 6.5 K/min Temperature change rate (heating): 7.5 K/min Heat compensation: 4,500 W Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm External dimensions: Width 870 mm x Depth 1,280 mm x Height 1,575 mm Viewing window: Width 300 mm x Height 540 mm Test chamber volume: 190 liters Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz Rated power: 10 kW Rated current: 21 A Supply-side fuse: 32 A slow-blow Sound level at 1 m distance (free-field measurement): < 63 dB(A) Lateral port: 50 cm / 125 cm Chamber is water-cooled Refrigerants: R452A and R23 Weight: approx. 460 kg Important safety information for buyers: The following procedures are carried out on all chambers offered by us: 1. Functional check and replacement of necessary components 2. If required, refilling with legally compliant refrigerant 3. Leak test with certificate 4. After successful inspection, all chambers are subjected to a documented trial run. Condition: used Scope of delivery: (see photos) (Technical data and specifications subject to change and errors!) If you have further questions, we are happy to provide information by phone.
Iajdpfxsyu Rhgs An Uor
Listing
Borken
1,034 km
Climate test chamber 335 liters with humidity
VötschVCS³ 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VCS³ 7034-5
Vötsch Climate Test Chamber, Water-Cooled
With temperature change rate of 5 K/min
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.5 K
Iaodpfxoygvn Ne An Uor
Spatial temperature deviation: ±0.5 K to ±2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.3 K
Spatial temperature deviation: ±0.5 K to ±1.0 K
Temporal humidity deviation in the center of the usable space: ±1% to ±3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH regulated for a maximum of 2 hours)
Exterior dimensions (W x D x H): 870 x 1700 x 1775 mm
Test chamber dimensions (W x D x H): 580 x 765 x 750 mm
Test chamber volume: approx. 335 liters
Side ports: 50 mm and 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulbs 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Rated power: 9 kW Rated current: 20 A
Customer-side fuse: 63 A slow-blow
Refrigerant: R404A / R-23
Weight approx. 570 kg
For your security as a buyer, please note the following:
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and errors!)
Further questions can be answered by phone.
Listing
Borken
1,034 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
Iajdpeygur Tofx An Uer
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing
Borken
1,034 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Ijdpeu H U Twefx An Uear
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have over the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
1,034 km
Climatic test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Ijdpfxeuudx Dj An Usar
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Type: VCS 7034-5
Climate Test Chamber Water-Cooled
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature deviation spatially: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 3.5 K/min
Heating: 6.8 K/min
Iajdpfx Ajxufypen Ujr
Heat compensation at +20°C: 3,000 W / at -20°C: 3,000 W
Temperature calibration points: +23°C and +80°C
Performance for climate tests:
Temperature range: +10 to +95°C
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Humidity deviation over time: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climatic calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions:
Width: 580 mm, Depth: 765 mm, Height: 750 mm
External dimensions:
Width: 870 mm, Depth: 1595 mm, Height: 1775 mm
Feedthroughs:
1 x approx. 50 mm Ø, left side
2 x approx. 125 mm Ø, left side
1 x approx. 125 mm Ø, right side
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R404A / R-23
For your security as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and errors!)
If you have further questions, we are happy to answer them by phone.
Listing
Borken
1,034 km
Temperature cabinet 110 liters
VötschVT 7011 -70°C bis +180°C
Call
Condition: excellent (used), Here we offer a Heraeus Vötsch temperature cabinet.
Heraeus Vötsch temperature chamber water cooled
Test chamber volume 110 liters
Test chamber dimensions: Width 560 mm Depth 350 mm Height 630 mm
Outer dimensions: Width 850 mm Depth 1030 mm Height 1640 mm
Temperature range - 70°C to +180°C
Temperature deviation in time ±0.1 to ±0.5 K
Temperature deviation spatial ±0.5 to ±1.5 K
Temperature gradient 1 to 3 K
Temperature change rate cooling 3.2 K/min
Temperature change rate heating 3,5 K/min
Refrigerant: R-404 A / R 23
Voltage 1/N/PE AC 230V±10% 50Hz
Rated power 1,8 kW
Rated current 12 A
Type: VT 7011
Iodpfxehrdy Ss An Uoar
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Climate test chamber with humidity 34 liters
VötschVCL 7003 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VCL 7003
Air-cooled climatic test chamber
Test chamber capacity approx. 34 liters
Capacity for temperature tests:
Temperature range -70 to +180°C
Temperature deviation over time ±0.3 to ±1.0 K
Temperature homogeneity over space ±0.5 to ±2.0 K
Heating rate of change 4.0 K/min
Cooling rate of change 3.0 K/min
Heat compensation max. 550 W
Temperature calibration value +23°C and +80°C
Iaodjv Tnd Sopfx An Ujr
Capacity for climatic tests:
Temperature range +10 to +95°C
Humidity range 10 to 98%
Humidity deviation over time ±1 to ±3%
Temperature deviation over time ±0.3 to ±0.5 K
Spatial temperature homogeneity ±0.5 to ±1.5 K
Climate calibration values +23 °C / 50% RH and +95 °C / 50% RH
Test room dimensions: Width 350 mm, Depth 300 mm, Height 310 mm
External dimensions: Width 640 mm, Depth 750 mm, Height 1730 mm
Electrical connection:
1/N/PE AC 230 V ±10%, 50 Hz
Rated current 11.0 A
Rated power, max. 2.5 kW
Sound pressure level 59 dB(A)
Refrigerant: R-404 A / R23
Weight approx. 130 kg
For your safety, please note the following information as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
We make it easier for you to find: "vötsch temperature test chamber -70°c to +180°c"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month



















































































































































































































































