Used Temperature Test Chamber 1540 Liters for sale (21,521)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
1,034 km
Climate test chamber with humidity
VötschVC³ 0100 0°C bis + 90°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 0100
Vötsch Climate Test Chamber, Air-Cooled
Internal Test Chamber Dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall Device Dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Test Chamber Volume: 990 litres
Temperature Testing:
Minimum Temperature: -0°C
Maximum Temperature: +90°C
Temperature Change Rate, Cooling: 0.2 K/min
Temperature Change Rate, Heating: 0.5 K/min
Temporal Temperature Deviation: ±0.1 to ±0.5 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Heat Compensation at +20 °C: 350 W
Hedoygut Repfx Aqpsfh
Climatic Testing:
Minimum Temperature: +10°C
Maximum Temperature: +90°C
Dew Point Temperature Range: +4°C to +89.5°C
Humidity Range: 10 to 98% r.h.
Temporal Humidity Deviation: ±1 to ±3% r.h.
Temporal Temperature Deviation: ±0.1 to ±0.3 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Refrigerant: R-404A
Weight: approx. 1400 kg
Important information for you as a buyer:
The following measures are carried out on our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and error!)
For further questions, we are happy to assist you by phone.
Listing
Borken
1,034 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall unit dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Port openings: Ø 125 mm, Ø 50 mm
Temperature test specifications:
Temperature range: -42°C to +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Max. heat compensation at +20°C: 4500 watts
Hfsdpfxeygutwj Aqpsh
Climatic test specifications:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1% to ± 3% r.h.
Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
For your security as a buyer, please note the following information!
The following points are checked and carried out on all our chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. If needed, fresh filling with legally compliant refrigerant
3. Leak check with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Subject to prior sale, changes and errors in technical data and specifications reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
1,034 km
Climatic test chamber -5°C...+90°C
WeissWK111-600 600 Liter
Call
Condition: used, Weiss
Type: WK111-600
Weiss Climate Test Chamber, Air-cooled
Performance Data for Temperature Tests:
Temperature range: -5°C to +90°C
Temporal temperature fluctuation: ±0.1 to ±0.5 K
Hfsdpfx Aeygum Dsqpjh
Spatial temperature deviation: ±0.5 to ±1 K
(corresponds to temperature gradient): 1 to 2 K
Temperature change rate:
Heating: 0.5 K/min
Cooling: 0.2 K/min
Performance Data for Climatic Tests:
Temperature range: +10 to +90°C
Humidity range: 10 to 98% r.h.
Temporal temperature fluctuation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
(corresponds to temperature gradient): 1 to 2 K
Temporal humidity fluctuation: ±1 to ±3%
Test Chamber Dimensions: Width 800 mm x Depth 800 mm x Height 950 mm
Housing Dimensions: Width 1000 mm x Depth 1660 mm x Height 1975 mm
Access Ports:
1 access port Ø 50 mm on the left side installed
1 access port Ø 125 mm on the right side installed
Power Supply: 1/N/PE AC 230V ±10% 50Hz
Rated power: 2.3 kW
Rated current: 10.0 A
Refrigerant: R 404 A
Capacity: 600 liters
Weight: 540 kg
For your security as a buyer, please note the following information!
The following steps are performed on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors excepted!)
If you have further questions, feel free to contact us by phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
1,034 km
Climate test chamber with humidity
CTSCS-70/350 350 Liter -70°C /+180°C
Call
Condition: excellent (used), Here we offer you a climate chamber.
Water-cooled
Test chamber volume: 350 liters
Internal chamber dimensions: Height 750 mm, Width 650 mm, Depth 720 mm
External dimensions: Height 1800 mm, Width 850 mm, Depth 1640 mm
Temperature working range:
Temperature range: -70°C to +180°C
Cooling rate: 3.0 K/min
Heating rate: 5.0 K/min
Climate working range:
Temperature range: +10°C to +90°C
Humidity range: +10% to 98% RH
Dew point range: +5°C to 89.5°C
Temperature deviation: ±0.1 - ±0.3 K over time
Humidity deviation: ±1 - ±2% RH over time up to 90% RH
max. ±1 - 3% RH over time above 90% RH
Electrical connection: 400V +6-10%, 3/N, 50Hz
Connected load: 13 kW
Rated current: 25.5 A
Refrigerant: R404A / R23
Weight: 650 kg
Type: CS-70/350
For your safety as a buyer, please note the following information:
The following steps are performed in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a trial run which is monitored with calibrated equipment.
Hedpfxeygumkj Aqpofh
Condition: used
Scope of delivery: (see photo)
(Specifications, technical data and details may be subject to change. Errors excepted.)
For any further questions, we are happy to assist you by phone.
Listing
Borken
1,034 km
Dust test chamber dust chamber
Testzentrum Baden Primus EngineeringDST350
Call
Condition: excellent (used), Primus Engineering
Type: DST 350
This test device was designed to carry out IP protection class tests “dust” according to
e.g. DIN 40050 Part 9 and DIN EN 60529.
The test device is intended for testing technical components under the influence
of dust and negative pressure within the limits specified in the technical data.
Operation / HMI
Control panel with screen and buttons
Manual controllers
Stored test sequences
Integrated vacuum circuit with flow measurement
Technical data:
Total electrical output: Max. 5 KW
Hfjdsrt U Nuspfx Aqpeh
Connection voltage: 400V/50HZ 3-Ν/ΡΕ (16AEEC socket)
Dimensions: Width approx. 920 mm Depth approx. 710 mm Height approx. 1,770 mm
Dimensions of test chamber: Width approx. 700 mm Depth approx. 650 mm Height approx. 770 mm
Volume approx. 350 I
Mass: approx. 200 kg
Vacuum: 0 to -100 mbar
Suction air flow: 0 to approx. 5 l/min
Working climate range: Temperature: +12 °C to +30 °C
Humidity: 25% rel. H. to 75% rel. F.,
non-condensing
Protection class tests according to DIN 40050 Part 9 and DIN EN 60529 (VDE 0470 Part 1)
Dust test:
Dust-protected ΙΡ5Χ and IP5KX
Dust-tight ΙΡ6Χ and IP6KX
with and without vacuum
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Climatic chamber temperature and humidity
EspecPL-2KPH -40°C bis 180°C
Call
Condition: excellent (used), Espec
Hodpjx Iu I Sefx Aqpofh
Model: PL-2KPH
ESPEC PL-2 KPH Climate Chambers, Air-Cooled
Temperature range: -40°C to +180°C
Humidity range: approx. 10 to 98% RH
Dependence on temperature range and humidity fluctuations:
± 2.5% RH over time, ± 3.0% RH
Internal dimensions (WxHxD): 500 × 750 × 600 mm
External dimensions (WxHxD): 910 × 1590 × 973 mm
Microprocessor control with 10 pre-set international test standards and 20 freely programmable memory slots,
as well as built-in timer with programmable start/stop automation and error code display.
Programming via touch screen.
Alarm display (audible and visual).
Device protection against overtemperature:
Overtemperature protection with two switching contacts
Illumination of testing chamber
Operating hours counter
Test chamber volume: 225 liters
Net weight: 300 kg
Electrical connection: 400 V 3/N 50 Hz,
Plug: CEE 16 A, max. current: 11.0 A
Refrigerant: R404A
Scope of delivery: Espec climate test chamber
Buyer information for your security:
The following procedures are carried out in advance on the chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refilling with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photos)
(Specifications and technical details subject to change and errors!)
If you have further questions, please feel free to contact us by phone.
Listing
Borken
1,034 km
Stress test chamber
EspecEHS-221MD
Call
Condition: excellent (used), Espec
Here we offer an Espec (ThermoTec) stress test chamber.
Outer dimensions: W x H x D: 860 x 1795 x 1000 mm
Test chamber dimensions W x H x D: 355 x 355 x 426 mm
2 x 46 l
Voltage 230 V 1/N 50 Hz
Rated current 37A
Fuses 250 V , 2 x 3 A
Type: EHS-221MD
Temperature range: + 105°C to + 142.9°C
Humidity range 75 to 100 % r.H.
Temperature constancy: -+ 0.5 °C
Hfjdpfx Aopdm Uyjqpjh
Pressure range: 0 to 2.0 kg/cm²
Heat-up or pressure build-up time: from 0 to 2.0 kg/cm² in about 60 minutes
390 kg
Condition: Used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Climate chamber with humidity 34 liters
WeissWKL 34/60 -60°C bis 150°C
Call
Condition: excellent (used), White
Type: WKL 34/60
Weiss air-cooled climate chamber
Refrigerant converted to R-452A
-60°C to 150°C
Room volume: 34 liters
Entry port installed in basic equipment:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm Width 324 mm Depth 300 mmm
External dimensions: Height 1740 mm Width 630 mm Depth 970 mmm
Characteristic values for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation in space (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Characteristic values for climate tests:
Temperature range +10 to +95 °C
Humidity range 10 to 98 %r.H.
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation in space ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 %RH
Data for operation:
Hjdpfstr Dinjx Aqpjfh
Test room lighting Halogen bulb 12V, 20W
Nominal voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
On-site fuse 16A slow-blow
Heat dissipation air-cooled test chambers
Max. Heat dissipation to surroundings 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hfedpfx Aewxc I Ueqpoh
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
For further questions, please feel free to contact us by phone.
Listing
Borken
1,034 km
Temperature cabinet 990 liters
WeissWT3-1000/40 -40°C bis +180°C
Call
Condition: excellent (used), White
Type: WT3-1000/40
Weiss Temperature test chamber With S!MCON / 32 control unit Water-cooled
Touch panel" control unit
All control and operating commands can be triggered by simply touching the function icons on the
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 990 liters
Test chamber dimensions: Height 950 mm, width 1100 mm, depth 950 mm
External dimensions: Height 2000 mm, width 1415 mm, depth 2105 mm
Data for temperature tests:
Temperature range: -40 to +180 °C
Temperature deviation in time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 4500 W
Data for operation:
Test room lighting Halogen bulb 2x 24V, 50W
Nominal voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 22.0 A Rated power 11.5 kW
On-site fuse 32 A slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front. 1m height 56 dB(A)
Refrigerant: R-404A
Weight: 840 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Hfjdpfx Aethhw Asqpjh
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Temperature cabinet 110 liters
VötschVT 7011 -70°C bis +180°C
Call
Condition: excellent (used), Here we offer a Heraeus Vötsch temperature cabinet.
Heraeus Vötsch temperature chamber water cooled
Test chamber volume 110 liters
Test chamber dimensions: Width 560 mm Depth 350 mm Height 630 mm
Outer dimensions: Width 850 mm Depth 1030 mm Height 1640 mm
Temperature range - 70°C to +180°C
Temperature deviation in time ±0.1 to ±0.5 K
Temperature deviation spatial ±0.5 to ±1.5 K
Hfedjhrdy Sepfx Aqpsh
Temperature gradient 1 to 3 K
Temperature change rate cooling 3.2 K/min
Temperature change rate heating 3,5 K/min
Refrigerant: R-404 A / R 23
Voltage 1/N/PE AC 230V±10% 50Hz
Rated power 1,8 kW
Rated current 12 A
Type: VT 7011
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Stress test chamber
Espec (ThermoTec)TPC-212D
Call
Condition: excellent (used), Espec
Type: TPC-212D
Technical Specifications
Test Procedure: HAST – Highly Accelerated Stress Test
Model: Espec TPC-212D
Internal Volume: 2x (approx. 22 liters)
Internal Dimensions (ø x L mm): 2x 295 x 330 mm
Temperature Range: +105 °C to +142.9 °C
Humidity Range: 75% to 100% RH
Pressure Range: 0.02 to 0.196 MPa gauge (0 to 28 psig)
Power Supply: 220 V (±5%), 1-Phase, 50/60 Hz, 20 A
Special Features: Two chambers in one device
Notes:
Two chambers: Allow for simultaneous tests with different parameters or larger test volumes.
HAST test: Accelerated endurance test under high temperature and humidity
with overpressure for the qualification of electronic components.
Applications: Ideal for semiconductors, ICs, circuit boards, MEMS, etc.
Weight: 230 kg
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
Hfsdpfx Ajwl D Aaoqpsh
We are happy to answer any further questions over the phone.
Listing
Borken
1,034 km
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Hjdpfx Asv N Hc Ejqpsfh
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Designation: SB2/500/80 water cooled
Cold-heat operation: -75°C ...+180°C
Climatic operation: +10...+95°C
Humidity range: 10...98 % r. h.
Temperature constancy, temporally ± 0.2K
Humidity constancy: ±1 r.F.
Temperature rate of change:
Cooling: approx. 1.4 K/min
Heating up: approx. 2.5 K/min
External dimensions: Height 1980 mm, width 1265 mm, depth 1365 mm
Feedthroughs:
left side: ∅ 100 mm
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/ 50 Hz
Power: 10,4 kVA
Weight: approx. 720 kg
Refrigerant R404a / R 23
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
Hfodpjm Tvzcofx Aqpoh
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: SB2/500/80
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Temperature chamber
WEISSWT11-1000/70/5
Call
Condition: excellent (used), Weiss temperature chamber
Here we offer a Weiss temperature chamber.
Weiss temperature chamber air cooled with Weiss condenser cooler
Test chamber capacity approx. 990 liters
Data for temperature tests:
Temperature range -70°C to +180°C
Temperature deviation in time in the center of the chamber ± 0.1 to ± 0.5 K
Temperature deviation spatially ± 0.5 to ± 2.0 K
Temperature gradient (acc. to IEC 60068-3-5) 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating 5 K/min
Cooling 5 K/min
Heat compensation max. 2750 W
Feedthrough built into basic equipment
R1: NW 125 mm
L1: NW 50 m
Dimensions:
Test chamber dimensions: Width 1100 mm x depth 950 mm x height 950 mm
Housing dimensions: width 1390 mm x depth 1525 mm x height 1995 mm
maximum load (evenly distributed over the surface) of the test chamber floor 150 kg
per insert grate 50 kg
total load of the grate supports 100 kg
Data for operation:
Test room lighting halogen bulb 24V, 50W
Rated voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 27,0 kW
Hodpop Dun Asfx Aqpsfh
Rated current 42,02 A
Heat output water-cooled test chambers max. heat output to environment 1.3 kW
Noise measurement:
Sound pressure level approx. 64 dB(A)
Refrigerant: ( converted to R-452a )
weight: approx. 960 kg
Type: WT11-1000/70/5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. function check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Heraeus shock test chamber
Here we offer a shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
The temperature range of the warm chamber is from +50°C to +220°C.
Temperature deviation temporally in useful chamber center ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -65°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
Hfedpjikvlxsfx Aqpoh
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: HT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Temperature chamber
ThermotronSE-1000-5-5
Call
Condition: excellent (used), Thermotron temperature chamber
Here we offer you a Thermotron temperature chamber.
Water cooled
Thermotron temperature chamber SE-1000-5-5
Dimensions of the working area - WxDxH: 102 x 100 x 97 centimeters
Working area volume: 986 liters
Temperature uniformity: ± 0,5°C
Hfjdpfsirmitex Aqpjh
Temperature range: -70ºC to 180ºC
Temperature control tolerance: 0.3°C
Infeed dimensions - WxDxH: 122 x 188 x 218 centimeters
Electrical requirements 400/3/50 32,4 A
Refrigerant: R-404A / R23
Approx. weight: 862 kg
Type: Thermotron SE- 1000-5-5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Climate test chamber Temp. -70 to 180°C
Weiss explosionsgeschütztWK-600/70 (I)-(II) 2 G EEx
Call
Condition: excellent (used), Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss climate chamber water-cooled
(test room explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST ROOM
Technical data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Test room capacity: approx. 600 liters
Cold / heat operation -70 to 180°C
Climate operation 10 – 95°C
Humidity 10...98% r. H.
Temperature change per time
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Hjdpfx Ajv Ewy Hsqpofh
On-site fuse: 32 A slow-blow
Permissible test item weight
Total load of the grate supports 80 kg
Test room floor 80 kg, grate insert 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(The air conditioning system's evaporator has been replaced)
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Corrosion testing device salt spray chamber
Gebr. LiebischS 1000 A-TR / 42016211
Call
Condition: excellent (used), Liebisch
Type: S 1000 A-TR / 42016211
Chest-mounted units with a 1000-liter test chamber volume for salt spray testing.
Constamatic® TR
This series includes automatically controlled chest-mounted units of type A-TR.
The internal controls are operated via a touchscreen.
All functions are displayed on a touchscreen with intuitive user guidance.
Technical specifications:
Device type: S 1000 A-TR
External housing dimensions: (W x D x H in mm) 2600 x 1120 x 1210
Internal test chamber dimensions: (W x D x H in mm) 1535/1425 x 800/780 x 660/650
Max. sample holder load: 10 kg / level 10 kg
Operating voltage: 230 V +6/-10%
Power consumption S: 2700 W
Humidity control range. S: up to / 70°C
Test chamber control range K: up to / 50°C
Test chamber control range S: up to / 50°C
Hfsdpfx Aqowf Dh Njpoh
Frequency: 50/60 Hz
Device fuse: 12 A
Temperature control: PLC
Overtemperature protection: yes
Test chamber volume: 1000 liters
Test solution storage capacity: approx. / 150 liters
Test solution consumption per hour: approx. / 0.7 - 1.0 liters
Water filling of base pan KON: 15 liters
Weight: 450 kg
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Emission test chamber
WEISSWT 5,1'/ + 18-45
Call
Condition: excellent (used), Weiss
Here we offer a Weiss emission test chamber.
Mini - SHED for Diurnal Loss Measurements
Test chamber dimensions: Width 1600 mm x Depth 2140 mm x Height 2150 (Usable 1600) mm.
Housing dimensions: Width 1760 mm x depth 3100 mm x heights 2790 mm
Max. floor load 250 kg
Operating range +18 °C ...+45 °C, (at higher temperatures SHED operation is only possible without Tedlar bag)
Temperature range +18 °C ...+45 °C
Temperature constancy ≤ ±1 K (temporal)
Temperature change rate, (heating and cooling) approx. 0.5 K/min., without test material
Duct connection (air inlet and outlet) ∅ 80 mm, in chamber rear wall
Shut-off valve, gas-tight (air inlet and outlet) ∅ 80 mm, gas-tight, pneumatic operation Delivery limit: connection flange of shut-off valve
Hodomfny Iepfx Aqpefh
Cooling water consumption approx. 0.8 m3/h
Voltage: 230/400 V; 3 PH + N + PE; 50 Hz
Rated power: 4,1 kW Rated current: 14,0A
Weight: approx. 2500 kg
type: WT 5,1'/ + 18-45
Condition: used / used
Sale ex location
Scope of supply: (Only the Weiss emission test chamber WT 5,1'/ + 18-45 Mini-SHED)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Germany
1,034 km
Stress test chamber
EspecEHS-221M
Call
Condition: excellent (used), Espec
Here we offer an Espec(ThermoTec) stress test chamber.
Overpressure humidity tests at over 100 degrees in many different modes
Program capacity of 10 patterns with 30
steps per pattern
A variety of protection mechanisms; overheat/overpressure protection, detection of water-
Hedpfx Aqen Arznspjfh
supply failure.Complete door interlock and temperature sensor.
Saturated Temp Range 105 to 142.9°C
Unsaturated Temp Range 105 to 132.9°C
Humidity range 50 to 100% r.h.
Nominal pressure 0.196 MPa at 132.9°C and 100% e.F.
External dimensions: width 740 x height 1553 x depth 1000 mm
Test chamber dimensions: Width 355x Height 355 x Depth 426 mm
Other equipment:
with rails and grid
Test material connections in the interior
Type: EHS-221M
Scope of delivery: See pictures
300 kg
Condition: Used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
1,034 km
Shock test chamber
VötschVT 7012 S3
Call
Condition: excellent (used), Vötsch shock test chamber
Here we offer you a Vötsch shock test chamber.
Water cooled
Temp. range -80C to +220C
Hot chamber +50 to +220
Medium chamber -10 to +90
Cold chamber -80 to +70
Mains voltage 400V +-10% 3/N 50Hz
Rated current 30.5 A
Rated power 13.5 KW
Refrigerant VK : R 404A 3.00kg p*: 25bar
Refrigerant TK : R23 15bar p* : 25 bar
Condition: used / used
Type: VT 7012 S3
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Hodpfx Aen Avcueqpofh
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Climatic test chamber 800 L, -55°C to +180°C
WeissClimeEvent C/800/55a/25/S 25K/min
Call
Year of construction: 2020, condition: excellent (used), Weiss
Type: C/800/55a/25/S
Year of manufacture: 2020
Weiss ClimeEvent Climate Test Chamber, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load capacity: designed for a maximum load of 250 kg
Specifications for temperature testing:
Hfodpfx Aqow R Rt Ijpsh
Temperature range: -55 to +180°C
Temporal temperature fluctuation at chamber center: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (down to -45°C)
Heating compensation: max. 8000 W
Specifications for climate testing:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Climate performance data (excerpt)
Humidity range: 10 to 98% relative humidity (RH)
Humidity deviation (temporal):
At chamber center, in steady-state condition, depending on climatic setting:
±1 to ±3% RH
Temperature deviation (temporal):
At chamber center, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20% RH):
±0.5 to ±1 K
Operational data:
LED strip: 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10%, 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
Chamber is equipped with Greenmode
Weight: approx. 2050 kg
Buyer Safety Information!
The following steps are performed on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful testing, chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)
For further questions, we are happy to answer your call.
Listing
Borken
1,034 km
Climatic test chamber
Feutron3702/06
Call
Condition: excellent (used), Feutron
Type: 3702/06
Water-cooled climatic test chamber
Technical data:
Test chamber nominal volume 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width 2970 mm Height 2370 mm Depth 1530 mm
Rear wall
Minimum insertion dimensions: Width 2970 mm Height 2390 mm Depth 1550 mm
Test chamber: Width 2000 mm Height 1000 mm Depth 1000 mm
Double-leaf door, clear width Width 2000 mm Height 1000 mm
Heated viewing window, 2 pieces Width 500 mm Height 600 mm
Feed-through opening, 1 side panel left ∅ 75 mm
Temperature range: -40...100°C
Climatic range: 10...95°C
Temperature difference, temporal ≤ ± 0.5...± 1.0 ΔN/K
Change rates measured in the supply air without load
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Humidity range: 10...95 %r. F.
Humidity difference, temporal ≤ ± 3.0 %r. F.
Dew point range, temporary down to -5... 95°C
Refrigeration system: water-cooled semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Air conditioning and dryer refrigeration system air-cooled /hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical mains connection: 400V 3/N/PE.AC,50Hz
Mains plug: CEE 5-роlig, 32 A, with 5.0 m cable
Max. simultaneous power requirement 10.0 kW
Supply line fuse: 3x 25, Char, C A
Degree of protection IP20
Weight: 1300 kg
Hfsdpfok E Hnqex Aqpsh
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Temperature shock test system
RS-SimulatorenST2K320/45
Call
Condition: excellent (used), RS Simulators
Type: ST2K320/45
Water-cooled shock test system
Working climate area
Hfedstqcu Eopfx Aqpeh
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Temperature: +12 °C to +30 °C
Humidity: 25% to 75% relative humidity
Dimensions Width 1100 mm Height 2300 mm Depth 2300 mm
Test chamber dimensions: Width 470 mm Depth 700 mm Height 440 mm
Electrical power supply:
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 850 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make it easier for you to find: "temperature test chamber 1540 liters"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
























































































































































































































