Used Vötsch Climatic Chamber for sale (5,482)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
1,034 km
Temperature test chamber 990 liters
VötschVT³ 4100 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4100
Water-Cooled Temperature Test Chamber
S!MCON/32.NET (with Touch Panel)
Control System Features:
- Color touchscreen with intuitive menu navigation (typically 5.7" or larger)
- Programming of temperature/humidity profiles with ramps and dwell times
- Data acquisition & logging (e.g., temperature profile, alarms)
- USB port for data export (CSV, optionally S!MPATI compatible)
- Network interface (Ethernet) for remote monitoring and control
- User management with password protection
- Interfaces: Volt-free contacts, optionally Modbus or Profibus
VT³ 4100 – Technical Specifications (Temperature Test Chamber)
- Test volume: 990 liters
- Temperature range: -40 °C to +180 °C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1.5 K
- Temperature gradient: 1 to 3 K
- Temperature change rate (per IEC 60068-3-5):
• Heating: 4.0 K/min
• Cooling: 3.0 K/min
- Maximum heat compensation capacity: 4500 W
- Calibration values: +23 °C and +80 °C
- Internal dimensions (W×D×H): 1100 × 950 × 950 mm
- External dimensions (W×D×H): 1390 × 1955 × 1995 mm
Feed-Throughs:
Pjdpeygvm Eefx Ad Negk
The chamber is equipped with feed-throughs on both the right and left sides, allowing insertion of measuring cables and test devices into the test space.
• 1 × L1 nominal width 50 mm
• 1 × R1 nominal width 125 mm
• 3 × R1 nominal width 50 mm
Electrical connection: 3/N/PE AC, 400V ±10%, 50Hz
Power consumption: 11.5 kW
Rated current: 22 A
Noise level: approx. 62 dB(A)
Refrigerant: R452A
Weight: 920 kg
Important information for buyers:
For your security, the following measures are carried out on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data; information may be subject to alteration!)
For any further questions, feel free to contact us by phone.
Listing
Borken
1,034 km
Temperature test chamber 1540 liters
VötschVT³ 4150 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4150
Vötsch Temperature Test Chamber, Air-Cooled
Temperature Testing
Temperature Range: -40°C to +180°C
Rate of Change: Cooling approx. 2.5 K/min
Rate of Change: Heating approx. 3.5 K/min
External Dimensions (W x D x H): approx. 1390 x 2380 x 1995 mm
Test Chamber Dimensions (W x D x H): approx. 1100 x 1475 x 950 mm
Rated Voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated Power: 11.5 kW
Rated Current: 22.0 A
Weight: approx. 1020 kg / 1540 liters
Refrigerant: R 404A
For your safety as a buyer, please note the following information:
We perform the following steps on all chambers offered:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: Used
Scope of delivery: (see photo)
(Technical data subject to change and errors excepted!)
Pjdpfxoygux Tj Ad Negk
For further questions, feel free to contact us by phone.
Listing
Borken
1,034 km
Temperature test chamber
VötschVT³ 4150/S
Call
Condition: excellent (used), Vötsch
Model: VT³ 4150/S
Vötsch Temperature Test Chamber
Water-cooled
Rated voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 11.5 kW; Rated current: 22.0 A
Change rate (cooling): approx. 3.5 K/min
Change rate (heating): approx. 4 K/min
Temperature testing
Temperature range: -40°C to +180°C
Layout drawing
External dimensions (W x D x H): approx. 1390 x 2380 x 1995 mm
Test chamber dimensions (W x D x H): approx. 1100 x 1475 x 950 mm
Weight: approx. 1020 kg / 1540 liters
Refrigerant: R 404A
For your safety as the buyer, please note the following information!
The following items are carried out on all chambers offered by us:
1. Functional inspection and replacement of necessary components
2. If needed, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see photo)
(Technical data and information subject to change and errors excepted!)
Pjdeyguuzepfx Ad Nsgk
We are happy to answer further questions by telephone.
Listing
Duxford
585 km
LABCOLD RLDF1510 Climatic Class 4 Refrigerator
LABCOLD RLDF1510 Climatic Class 4 RefrigeratorLABCOLD RLDF1510 Climatic Class 4 Refrigerator
Call
Condition: used, This listing is for the LABCOLD RLDF1520 Climatic Class 4 Refrigerator
The unit is in full working condition and is ready for immediate use
The LABCOLD RLDF1510 is a pharmacy / vaccine‑grade refrigerator designed for storage of temperature‑sensitive medicines, vaccines, or biological materials
Some of its key specs and features:
Feature Specification / Detail
Capacity ~ 430 litres
External Dimensions (H × W × D) 1860 mm × 600 mm × 700 mm
Pgsdpfx Adjxhdtho Nsk
Temperature Operating Range +2 °C to +8 °C (nominal operating ~5 °C)
Control / Monitoring “IntelliCold™” controller, 24/7 temperature logging, alarms (high/low temp, door open, power failure)
Insulation / Construction Enamelled steel exterior, corrosion‑resistant painted aluminium interior; fan‑assisted cooling; off‑cycle auto defrost
Door Type Solid door (non‑glass) version
Other Features Door lock with keys, access port for probe, remote alarm contacts, data storage (13 months)
Power / Energy Use Often quoted ~ 5.52 kWh/24h (for a 440 L variant/related model)
In short: this is a robust, regulated refrigerator intended for cold chain use (i.e. storage of medicines, vaccines, biologics) rather than for general domestic or food us
Listing
Borken
1,027 km
Temperature test chamber
VötschVTR 7033/S
Call
Condition: good (used), Year of construction: 1996, Vötsch VTR 7033/S Temperature test chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item no.: 60885637
Temperature chamber
Temp. range: -70°C to +180°C
Mains voltage:400V
Rated current:24A
Rated output: 9.5 kW
Refrigerant VK: R 404 A
Refrigerant TK: R 23
Year of manufacture: 1996
Pgsdpfjwbpzmsx Ad Nek
TK 07
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You will find further articles - new and used - in our store!
International shipping costs on request!
Listing
Borken
1,027 km
Temperature shock test chamber
VötschVT 7030 S2
Call
Condition: good (used), Year of construction: 1998, Vötsch VT 7030 S2 Temperature Shock Test Chamber -80 °C to +220 °C
The Vötsch VT 7030 S2 Environmental Test Chamber is designed for laboratory applications that require testing of materials and components in a known environment. With its versatile capabilities and easy-to-use controls, this programmable unit can be used to simulate a variety of environmental conditions for scientific studies, product testing and process control.
Data for temperature tests in single chamber operation
Hot chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range +50 °C to +220 °C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation in space ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 11 K/min
Cold chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range -80 °C to +70 °C
Temperature deviation in time in the middle of the usable space ± 1 K
Temperature deviation in space 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 1.5 K/min
Cooling 4K/min
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10 % , 50 Hz
Rated power: 30 kW
Rated power: 50 A
Refrigerant: R-404a /R-23
Chiller: Water-cooled
Weight: approx. 940 kg
Year of construction. 1998
Test room dimensions: Width 770 mm x depth 650 mm x height 610 mm
Housing dimensions: Width 1200 mm x depth 1800 mm x height 2050 mm
Podpjwbdv Sjfx Ad Negk
TS 05
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items - new and used - can be found in our store!
International shipping costs on request!
Listing
Borken
1,027 km
Temperature test chamber
VötschVT 7100
Call
Condition: excellent (used), Heraeus Vötsch VT 7100 Temperature test chamber -70°C to +180°C
Heraeus Vötsch
Temperature test chamber
VT 7100
-70°C to +180°C
1035 liters
Pjdpfjph Uzxex Ad Nsgk
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further articles - new and used - you will find in our store!
International shipping costs on request!
Listing
Borken
1,027 km
Temperature shock test chamber -70-220°C
VötschVT 7012 S2
Call
Year of construction: 2000, operating hours: 104,382 h, condition: excellent (used), Vötsch Shock Test Chamber VT 7012 S2
System for extreme temperature cycling
Temperature shock testing is used to test the resistance of components, devices, and other products to rapid changes in ambient temperature.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
These cyclical stresses and the accelerated aging caused by temperature changes reveal weaknesses in the test specimen.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the car
Cart load capacity 50 kg for VT3 7012 S2
All-around grilles in the car secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
Hot chamber can be used as a temperature storage unit, cold chamber as a temperature exchange unit
Minimal energy consumption
No compressed air required
Manufacturer: Vötsch
Type: VT 7012 S2
Type: Temperature shock test chamber
Test chamber volume: 120 l
Nominal voltage: 400 V
Nominal power: 10 kW
Nominal current: 25 A
Refrigerant: R452A
Cooling unit: Water-cooled
Shock cooling (nitrogen cooling) via customer-supplied nitrogen
External dimensions
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class
Device: IP 42
Operating panel: IP 20
Control cabinet: IP 54
Temperature test parameters for single-chamber operation |
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class ...Temperatur Temperature range
Pjdpfx Adex Exmto Njgk
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: ±2 K
in steady state
Temperature deviation over space: ±2 K
in steady state in the car
Heating rate, hot chamber: 11 K/min
Cooling rate, cold chamber: K/min
Heating rate, cold chamber: 2 K/min
Cooling rate, hot chamber: K/min
Observation window: 355 x 355 mm
Pipe opening: 67 mm
Year of manufacture: 2000
Operating hours: 104,382
Weight: 1000 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items – new and used – can be found in our shop! International shipping costs on request!
Listing
Borken
1,027 km
Drying cabinet Chamber oven
VötschVTU 100/150
Call
Condition: good (used), Vötsch VTU 100/150 heating and drying cabinet
Manufacturer: Vötsch
Type: VTU 100/150
Nominal temperature: 250 °C
Usable volume: 1500 m³
Total load: 400 kg
Nominal power: 27 kW
Connected load: 29 kW
Pjdpfx Asxbgt Ded Nsgk
Nominal current: 42 A
Mains connection: 400 V, 3 PH+N PE, 50 Hz
Weight: 780 kg
Microprocessor-controlled temperature and program controller
Jumo two-point controller
Digital display of setpoint/actual temperature, plain text display
Easy loading of the device floor via folding ramp
Dimensions
Interior: (W x H x D) 1000 x 1500 x 1000 mm
External: (W x H x D) 1840 x 2389 x 1450 mm
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You can find more items—new and used—in our shop!
International shipping costs on request!
Listing
Borken
1,034 km
Testing of lithium-ion batteries
VötschVC³ 4018/S Li-Ion CO/CO
Call
Condition: excellent (used), Vötsch
Type: VC³ 4018/S
Vötsch VC³ 4018/S Climate Test Chamber – Li-Ion CO/CO₂
−42 to +150 °C 400 V Air-cooled
For sale is a temperature and climate test chamber from the renowned German manufacturer Vötsch Industrietechnik GmbH, model VC³ 4018/S, year of manufacture 2012. The unit is specifically equipped for testing lithium-ion batteries and features CO monitoring as well as CO₂ inertization for enhanced operational safety.
Important Note:
Due to these safety features, the test chamber is software-limited to a temperature range of −42 °C to +150 °C.
The chamber is ideally suited for:
- Li-Ion battery testing
- Electronics and assembly testing
- Temperature and climate stress tests
- Development and quality assurance tasks
Technical Data:
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
External dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Feed-throughs included as standard:
R1: Ø 125 mm
L1: Ø 50 mm
Data for temperature tests:
Temperature range: -42°C to +150°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Pgodpfxjx Slm Hs Ad Nok
Heating 4 K/min
Cooling 4 K/min
Max. heat compensation: 2300 W
Data for climate tests:
Temperature range: +10 to +95 °C
Dew point range: -3 to +94 °C
Humidity range: 10 to 98 % RH
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1 to ± 3 % RH
Heat compensation: 400 W
Operating data:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
3/N/PE AC 400V ±10% 50 Hz
Rated power: 4.1 kW
Rated current: 14 A
Refrigerant: R-404A
Weight: 470 kg
Important Safety Information for Buyers!
The following servicing steps are performed on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If required, new refill with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: Used
Scope of delivery: (See image)
(Specifications and technical data are subject to change and errors are excepted!)
If you have further questions, we are happy to assist you by phone.
Listing
Borken
1,034 km
Heat cabinet with nitrogen supply
VötschTU 60/60 G-ISO Temp. 250°C
Call
Condition: excellent (used), Here we offer a bird heat cabinet with nitrogen supply.
Vötsch heat cabinet with nitrogen supply
Nominal temperature: 250°C
Name stream: 10 A
Connection value: 6.3 KVA
Nominal voltage: 400V3coma N)PE AC 50/60hz
Nominal power: 6 KW
Type: TU 60/60 G-ISO
Condition: used/used
Pedpfx Adjd Ngg Tj Negk
Delivery: (See picture)
(Changes and errors in the technical data, information is reserved!)
We can answer more questions on the phone for you.
Listing
Borken
1,034 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Pgedou H U Twspfx Ad Nek
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Type: VCS 7034-5
Climate Test Chamber Water-Cooled
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature deviation spatially: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 3.5 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3,000 W / at -20°C: 3,000 W
Temperature calibration points: +23°C and +80°C
Performance for climate tests:
Temperature range: +10 to +95°C
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Humidity deviation over time: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climatic calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions:
Width: 580 mm, Depth: 765 mm, Height: 750 mm
Pedpfxoxufypo Ad Negk
External dimensions:
Width: 870 mm, Depth: 1595 mm, Height: 1775 mm
Feedthroughs:
1 x approx. 50 mm Ø, left side
2 x approx. 125 mm Ø, left side
1 x approx. 125 mm Ø, right side
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R404A / R-23
For your security as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and errors!)
If you have further questions, we are happy to answer them by phone.
Listing
Borken
1,034 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Psdpewxc I Uefx Ad Nogk
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
For further questions, please feel free to contact us by phone.
Listing
Borken
1,034 km
Oven
VötschNTU 60/60
Call
Year of construction: 1996, condition: good (used), Here we offer a Voetsch drying oven Waermeschrank Waermeofen.
Voetsch NTU 60/60 250°C
Nominal temperature: 250°C
Supply voltage:
400 V 3 (N) PE AC, 50/60 Hz
Interior dimensions: width 600 mm/height 600 mm/depth 600 mm
External dimensions: width 1000 mm/height 1675 mm/depth 1300 mm
Psdpfx Adebqh I Se Nogk
Air circulation blower
Type: Voetsch NTU 60/60
Scope of delivery: (see picture)
(Changes and errors in the technical data are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Pgedpjun Izcofx Ad Njk
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
With humidity 270 liters
VötschKlimaprüfschrank VCS³ 7027-10
Call
Condition: excellent (used), Vötsch
Type: VCS³ 7027-10
Vötsch Climatic Test Chamber, Water-Cooled
With a temperature change rate of 10 K/min
Temperature test data:
Temperature range -72°C to +180°C
Temperature deviation over time in the center of the work space ± 0.3 K to ± 0.5 K
Temperature deviation over space ± 0.5 K to ± 2.0 K
Temperature change rate
Heating: 10 K/min
Cooling: 14.5 K/min
Climatic test data:
Temperature range +10°C to +95°C
(Extended climatic range: 2°C/95% RH, controlled for a maximum of 2 hours)
Temperature deviation over time in the center of the work space ± 0.2 K to ± 0.3 K
Temperature deviation over space ± 0.5 K to ± 1.0 K
Humidity deviation in the center of the usable space: ± 1% to ± 3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
External dimensions: Width 780 x Depth 1895 x Height 1775 (mm)
Pjdpfev R Ty Tjx Ad Negk
Test chamber dimensions: Width 580 x Depth 615 x Height 750 (mm)
Test chamber volume: approx. 270 liters
Side opening 50 mm
Side opening 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V±10%, 50 Hz
Rated power: 14 kW
Rated current: 26 A
Fuse, on-site: 63 A slow-blow
Refrigerant R404A/R-23
Weight approx. 835 kg
For your safety, please note the following information as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Temperature cabinet 110 liters
VötschVT 7011 -70°C bis +180°C
Call
Condition: excellent (used), Here we offer a Heraeus Vötsch temperature cabinet.
Pgodpfx Adshrdy Ss Nsk
Heraeus Vötsch temperature chamber water cooled
Test chamber volume 110 liters
Test chamber dimensions: Width 560 mm Depth 350 mm Height 630 mm
Outer dimensions: Width 850 mm Depth 1030 mm Height 1640 mm
Temperature range - 70°C to +180°C
Temperature deviation in time ±0.1 to ±0.5 K
Temperature deviation spatial ±0.5 to ±1.5 K
Temperature gradient 1 to 3 K
Temperature change rate cooling 3.2 K/min
Temperature change rate heating 3,5 K/min
Refrigerant: R-404 A / R 23
Voltage 1/N/PE AC 230V±10% 50Hz
Rated power 1,8 kW
Rated current 12 A
Type: VT 7011
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Dryer for coating materials
VötschLTU 60/60 LTU 60/60 200 °C
Call
Condition: excellent (used), Here we offer you a Heraeus Vöstch dryer for coating materials.
Maximum concentration of flammable substances of < 40 % of the lower explosion limit (LEL).
Highest temperature of the heating surface above 750 °C
Equipment description:
Technical data:
Interior (usable space) 0.216 m3
Inner dimensions: width 600 mm height 600 mm depth 600 mm
External dimensions: Total width 796 mm Height 1725 mm Depth 850 mm
Loading / load capacity
Roller conveyor total 55 kg
Loading height above installation floor 820 mm
Weight (net) kg 275
Minimum exhaust air volume flow 96 m3/h
Purge time 5-fold air change 90 sec.
Recirculation air volume flow increased 33 m3/h
Total steam space 0.414 m3
Sound pressure level (according to DIN 45635) < 70 dB(A)
Switch-off temperature
Pgjdpfx Ajhv Ru Sod Nsk
Temperature limiter (TB) fixed 300 °C
Temperature selector limiter (TWB) adjustable above nominal temperature 20
Temperature safety class (according to EN 60519-2)
Temperature limiter (TB) 1
Over-temperature limit controller (TWB) 2
Nominal temperature 200 °C
Electrical data
Rated voltage / frequency 400V, 3/(N)PE, AC 50/60Hz
Rated current 12.0 A Rated power 6.0 kW Connected load 7.0 kW
Weight: 275kg
Type: LTU 60/60
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Temperature test chamber
Heraeus VötschVTS 7033
Call
Condition: excellent (used), Heraeus Vötsch temperature test chamber
Podpfx Adelt U Avs Nsgk
Here we offer you a Heraeus Vötsch temperature test chamber.
Vötsch temperature test chamber VTS 7033 water cooled
Temperature range: -70°C to +180°C
Temperature deviation temporal ± 0,5 K
Temperature deviation temporal ± 1,5 K
Heating speed: 7,5 K/min
Cooling rate: 6.5 K/min
Test chamber dimensions: Width 825 mm x depth 800 mm x height 870 mm
housing dimensions: 1080 mm x 1710 mm x 1950 mm
lateral passage 12cm and 13cm
voltage: 400V+6/-10%,3/N, 50Hz
nominal power 9,5 kW nominal current 22 A
refrigerant R404A / R23
approx. 570 liters weight: 580 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored by calibrated equipment.
Type: VTS 7033
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Dryer for coating materials
VötschLTU 60/60
Call
Condition: excellent (used), Vötsch
Type: LTU 60/60
Heraeus Vötsch dryer for coating materials
Maximum concentration of flammable substances of 40 % of the lower explosion limit (LEL)
Highest temperature of the heating surface above 750 °C
Device description:
Technical data:
Interior (usable space) 0.216 m3
Internal dimensions: Width 600 mm Height 600 mm Depth 600 mm
External dimensions: Total width 796 mm Height 1725 mm Depth 850 mm
Loading / load capacity
Total roller conveyor 55 kg
Loading height above installation floor 820 mm
Weight (net) kg 275
Minimum exhaust air volume flow 96 m3/h
Purge time 5-fold air change 90 sec.
Increased recirculation air volume flow 33 m3/h
Total vapor space 0.414 m3
Sound pressure level (according to DIN 45635) < 70 dB(A)
Switch-off temperature
Temperature limiter (TB) fixed setting 300 °C
Temperature selector limiter (TWB) adjustable above nominal temperature 20
Temperature safety class (according to EN 60519-2)
Temperature limiter (TB) 1
Temperature selector limiter (TWB) 2
Nominal temperature 200 °C
Electrical data
Pedpoun Rr Rsfx Ad Nsgk
Rated voltage / frequency 400V, 3/(N)PE, AC 50/60 Hz
Rated current 12.0 A
Nominal power 6.0 kW
Connected load 7.0 kW
Weight: 275kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
1,034 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
Pjdpfx Adoun Ruls Nsgk
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Temperature test chamber
VötschVTS³ 7018-5
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7018-5
Pjdpon E Sk Esfx Ad Negk
Water-cooled
Test chamber dimensions: Width 580 mm x depth 450 mm x height 750 mm
Housing dimensions: Width 900 mm x depth 1550 mm x height 1850 mm
Temperature test:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Temperature change rate: cooling 7.5 K/min
Test chamber volume: 190 liters
Nominal voltage: 400V
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Refrigerant: R404A and R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Assemblies / Test cabinet
VötschVT 3050 -30°C / +100°C 500 Liter
Call
Condition: excellent (used), Vötsch
Type: VT 3050
Modules / Test Chamber Temperature Chamber
Air-cooled
Test chamber capacity 500 litres
Temperature range -30°C / +100°C
Temporal temperature fluctuation K ±0.5
Spatial temperature fluctuation K ±1.5
Temperature gradient K 3
Change rate
Heating K/min 2.0
Pjdpfx Adsw S E N Ts Negk
Cooling K/min 1.4
Heat compensation max. W 650
Calibration values +23°C +80°C
Test chamber dimensions Width 710 mm Depth 590 mm Height 1250 mm
External dimensions Width 940 mm Depth 1030 mm Height 1955 mm
Sound pressure level db(A)
Listing
Borken
1,034 km
Temperature test chamber spraying device
VötschVBT 03/500 500 Liter -30 bis 80°C
Call
Condition: excellent (used), Vötsch
Type: VBT 03/500
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Pgodpfx Ajwc Nvgsd Nsk
Temperature deviation in steady state
according to IEC 60068-3-5 dependent on the test chamber temperature
over time ± 1 K
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the insert grid
Water level = 0 mm
The water level is at the top edge of the insert grid
Data for standard spray device
Number of spray nozzles: 6
Spray volume per nozzle: 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles: 6
Spray volume per nozzle: 4.5 l/min
Additional flooding nozzles: 2
Spray volume of additional nozzle: 6 l/min
Compressed air consumption: approx. 3 m³/h
Data for water tank with pre-temperature control
Volume: approx. 2000 l
Temperature range for pre-temperature control +5°C to +40°C
Temperature change duration
Cooling of +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Installation and Operation Data:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Plug-ins
1 50 mm diameter plug installed on the left
Test chamber capacity: approx. 500 liters
Refrigerant R-404a
Electrical connection:
Nominal voltage 3/N/PE AC 400V ± 10% 50Hz
Nominal power approx. 26 kW
Nominal current approx. 44.0 A (neutral conductor loaded)
Fuse protection 63 A gG, on-site
Weight approx. 890 kg net
For your safety, please note the following information!
The following steps are carried out on our chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
We make it easier for you to find: "vötsch climatic chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you