Emergency generatorNotstromaggregat 2000 KVA MTU
16v396
Emergency generator
Notstromaggregat 2000 KVA MTU
16v396
Year of construction
1996
Condition
Used
Location
Königswinter 

Show images
Show map
Machine data
- Machine type:
- Emergency generator
- Manufacturer:
- Notstromaggregat 2000 KVA MTU
- Model:
- 16v396
- Year of construction:
- 1996
- Condition:
- excellent (used)
- Functionality:
- fully functional
- Operating hours:
- 250 h
Price & Location
- Location:
- Hauptstraße 371, 53639 Königswinter, Deutschland

Call
Details about the offer
- Listing ID:
- A18905271
- Update:
- 08.04.2025
Description
We have a 2000 KVA container generator for sale.
Optionally 400/230 V (50 Hz)
or 10 kV (+/- 5%) (50 Hz)
Fully installed in two soundproof 40' HC containers.
Suitable and intended for multi-layer installation.
Dimensions: (L x W x H) 12020 x 2500 x 5800 mm
Weight: approx. 33 t + 11 t
Engine: MTU 16v396 TB 34D
Generator: A.v. Kaick DIDBN 130/125 h/4
2000 KVA Generator
Engine and generator completely mounted on a base frame and connected via a flexible coupling.
Cooling system:
Separate table cooler installed as a dual-circuit cooler in the upper container, including temperature control, connecting lines (stainless steel cooling water lines with shut-off valves for each line), circulation pumps, control valves, etc. for safe operation.
Tank system:
4000-liter tank system installed in the upper container, including system-specific accessories and complete piping.
Air supply and exhaust system:
Soundproof baffles within the air supply and exhaust chambers in the container.
Air supply and exhaust openings each equipped with appropriate weather protection grilles, motor-operated blinds in the container that open automatically when the generator is in operation.
Exhaust system:
Insulated exhaust ducts within the container lead vertically from the container via silencers through the upper container, discharging the exhaust gases through the container roof.
Switchgear:
Medium/low-voltage switchgear for fully automatic emergency power operation!!!
Optionally 400/230 V or 10 kV (+/-5%)
Fully automatic machine monitoring with control for power failure detection, automatic start-up, and emergency power takeover. Upon power recovery, the system automatically switches back to the mains supply.
In the low-voltage range, parallel operation with the mains/resynchronization is possible.
Control for external mains switch - optionally 10 kV or 400/230 V
Low-voltage switchgear equipped with: 3200 A generator switch (400/230 V)
Medium-voltage switchgear equipped with: 115 A generator switch (10 kV)
Technical data of the type-tested medium-voltage switchgear
Panel type: ZS8
Bwsdpfxowa Tg Dj Afneh
Rated voltage: 12 kV
Operating voltage: 10 kV
etc.
The listing was translated automatically. Translation errors are possible.
Optionally 400/230 V (50 Hz)
or 10 kV (+/- 5%) (50 Hz)
Fully installed in two soundproof 40' HC containers.
Suitable and intended for multi-layer installation.
Dimensions: (L x W x H) 12020 x 2500 x 5800 mm
Weight: approx. 33 t + 11 t
Engine: MTU 16v396 TB 34D
Generator: A.v. Kaick DIDBN 130/125 h/4
2000 KVA Generator
Engine and generator completely mounted on a base frame and connected via a flexible coupling.
Cooling system:
Separate table cooler installed as a dual-circuit cooler in the upper container, including temperature control, connecting lines (stainless steel cooling water lines with shut-off valves for each line), circulation pumps, control valves, etc. for safe operation.
Tank system:
4000-liter tank system installed in the upper container, including system-specific accessories and complete piping.
Air supply and exhaust system:
Soundproof baffles within the air supply and exhaust chambers in the container.
Air supply and exhaust openings each equipped with appropriate weather protection grilles, motor-operated blinds in the container that open automatically when the generator is in operation.
Exhaust system:
Insulated exhaust ducts within the container lead vertically from the container via silencers through the upper container, discharging the exhaust gases through the container roof.
Switchgear:
Medium/low-voltage switchgear for fully automatic emergency power operation!!!
Optionally 400/230 V or 10 kV (+/-5%)
Fully automatic machine monitoring with control for power failure detection, automatic start-up, and emergency power takeover. Upon power recovery, the system automatically switches back to the mains supply.
In the low-voltage range, parallel operation with the mains/resynchronization is possible.
Control for external mains switch - optionally 10 kV or 400/230 V
Low-voltage switchgear equipped with: 3200 A generator switch (400/230 V)
Medium-voltage switchgear equipped with: 115 A generator switch (10 kV)
Technical data of the type-tested medium-voltage switchgear
Panel type: ZS8
Bwsdpfxowa Tg Dj Afneh
Rated voltage: 12 kV
Operating voltage: 10 kV
etc.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2021
Send inquiry
Telephone & Fax
+49 178 6... show
These listings may also fit your interest.
Listing
Viersen
1,022 km
Combined heat and power plant
MWMETW 800 EG-CO-KA
MWMETW 800 EG-CO-KA
Listing
Oberleichtersbach
1,284 km
Impact crusher
SBM10-6-4
SBM10-6-4
Listing
Enschede
1,025 km
Plate roller 4 rolls
Ostas4R OHS 1570 x 200
Ostas4R OHS 1570 x 200
Listing
Wiefelstede
1,085 km
730 kVA generator
MWM/PillerNKTB 4-1158
MWM/PillerNKTB 4-1158
Listing
Germany
1,414 km
Transformer
SGB RegensburgDTTHL 630/20
SGB RegensburgDTTHL 630/20
Listing
Yeşiloba
3,790 km
Chiller
YorkYVAA0273DUF50BAVNXX
YorkYVAA0273DUF50BAVNXX
Listing
Biebesheim am Rhein
1,222 km
Emergency generator
MWMTBD 232 V 12 Notstromaggregat
MWMTBD 232 V 12 Notstromaggregat
Listing
Alsfeld
1,230 km
Singlefacer Asitrade
AsitradeSinglefacer
AsitradeSinglefacer
Listing
Berlin
1,446 km
Internal Cylindrical Grinding Machine
JungC8
JungC8
Listing
Roreto
1,518 km
UNLOADER (SINGLE-CAGE)
RBO (BIESSE Group)Tornado SC 1300
RBO (BIESSE Group)Tornado SC 1300
Your listing has been deleted successfully
An error has occurred