Used Cts Klimaschrank Walk-In Temperature And Humidity Test Chamber for sale (34,127)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
1,027 km
Corrosion test chamber
NemaNSN 300
Call
Condition: good (used), Year of construction: 1999, Nema corrosion test chamber for salt spray tests
Manufacturer: Nema
Type: NSN 300
Rated voltage: 400 V
Rated current: 11 A
Compressed air: 8-10 bar
Air consumption: 6 Nm³/h
Humidifier: 0.5 l/h
Water pressure: 2-8 bar
Power consumption: 5.6 kW
Salt solution: NaCl: 50 +- 5.6 kW
External dimensions (WxDxH) 3200 x 1200 x 1900 mm
Internal dimensions of the test chamber (WxDxH) 3100 x 1000 x 880 mm
Weight: 390 kg
Financing through our bank is also possible.
Hodpeu Ecrxofx Agcenk
komplett-konzept.leasingo.de
Further items in other sizes - new and used - can be found in our store!
International shipping costs on request!
Listing
Borken
1,027 km
Corrosion climate change test chamber
WEISSSC 1000/+20IU
Call
Condition: excellent (used), Weiss SC 1000/+20IU Corrosion Climatic Cycle Test Chamber
Weiss SC 1000/+20 JU Corrosion Climatic Cycle Test Chamber
The test system is a combination of a climatic test chamber with variable temperature and humidity and a corrosion test chamber with a salt spray test.
At-risk metallic components are tested for corrosion in a time-lapse manner according to the relevant standards.
Temperature Working Range
Hnjdpsph U Dhefx Agcek
Temperature: +20 °C ... +60 °C
Temperature variation over time: +0.5 °C
Climatic Working Range
Temperature: +20 °C ... +60 °C
Temperature variation over time: +0.5 °C
Relative Humidity: 10...98 % RH
Temperature variation over time: 3...5 % RH
Dew point: +12 °C ... +59 °C
Salt spray test SS (ambient temperature range +5 °C ... +50 °C)
according to DIN 50 021 (salt spray via dual-fluid nozzle, 1.5 x 0.5 mV 80 cm h)
Control
Digital measurement and control system SIMCON/32*-Net with touchscreen control panel
Interfaces - Serial interface RS 232 C - Parallel printer interface
Operating modes adjustable via process controller:
- Temperature mode
- Air conditioning mode
- Salt spray test
- Direct spraying with saline solution
- Condensate load
- Flushing test chamber walls
- Drying/ventilating test chamber
Temperature sensor: Pt 100 resistance thermometer
Humidity sensor: Psychrome fresh measuring device TFT (with forced humidification)
Technical data SC 1000/+20 JU
Usable space dimensions
Height up to
sloped roof approx. 1000 mm
+ roof approx. 350 mm
Width approx. 1100 mm
Width between heaters approx. 1000 mm
Depth approx. 1000 mm
Test room door made of glass, hinged on the left
Height approx. 1350 mm
Width approx. 1000 mm
External dimensions including unit components and control cabinet
Height approx. 2100 mm
Width approx. 1450 mm
Width with touch control panel approx. 1700 mm
Depth approx. 2600 mm
Floor load max. 100 kg
Brine storage tank
approx. 200 l, with level monitoring separately next to/behind the unit
Height approx. 1000 mm
Width approx. 600 mm
Depth approx. 900 mm
Electrical connection: 400 V
Power rating: 13 kW
Weight: 1300 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items – new and used – in our shop!
International shipping costs on request!
Listing
Borken
1,027 km
Solar cells Photovoltaic Test chamber
Parker Hannifin GmbHVertical Light Stack Module
Call
Condition: like new (used), Year of construction: 2012, Parker Engineering & Design Vertical Light Stack Module
For testing solar modules Photovoltaic modules
Electrical and mechanical safety testing
Support for product development, design and quality control
Detection of potential problems during development
Quality and safety control
Endurance test stand
Temperature control
Mobile on rollers
Entry pockets for forklift trucks
400 VAC, 3.PH, 50 AMP
IR. 10,000 amp
Year 2012
Weight 1400 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further test equipment - new and used - you will find in our shop!
International shipping costs on request!
Hjdpeh Rvh Sefx Agcjnk

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
London
590 km
Chiller
Colsec LimitedWalk-In Chiller 7m x 2m
Call
Condition: excellent (used), functionality: fully functional, 1 x Colsec Limited walk-in chiller / fridge to store pallets of goods.
Exterior dimensions - 7m L x 2m W.
Interior dimensions - 6.8m long.
Electric supply - 3 phase.
Hodpfx Aex A A N Dsgcsnk
BUYER TO REMOVE
Listing
Wiefelstede
1,086 km
Air duct sensor humidity/temperature
SiemensQFM2160
Call
Condition: used, Duct sensor for rel. Humidity/temp. 2 x 0...10 V
-Type: QFM2160
for duct installation with mounting flange.
-Technical specifications:
-Measuring element temperature: active
-Measuring element humidity: capacitive humidity sensor
Hnsdpfeb H Ebfox Agcsk
-Operating voltage: 24 VAC 13.5...35 VDC
-Power consumption:
Listing
Wiefelstede
1,086 km
Air duct sensor humidity/temperature
SiemensQFM2160
Call
Condition: used, Duct sensor for rel. Humidity/temp. 2 x 0...10 V
Hnodpfxeb H Ebge Agcjk
-Type: QFM3160
for duct installation with mounting flange.
-Technical specifications:
-Measuring element temperature: active
-Measuring element humidity: capacitive humidity sensor
-Operating voltage: 24 VAC 13.5...35 VDC
-Power consumption:
Listing
Dortmund
1,081 km
High temperature chamber furnace
VEI-Engineering
Call
Condition: new, High temperature chamber furnace, make VEI
max. temperature: 1.200°C
useable dimensions (w x h x d): 2750 x 500 x 1.100 mm
Hsdodyvkyopfx Agconk
heating power: electrically, 42 kW
Listing
Borken
1,034 km
Climate chamber -75°C / +180°C with humidity
TIRATCC 7120
Call
Condition: excellent (used), TIRA
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the usable space) ±0.1°C ... ±0.3 °C
Maximum temperature change rate
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time ±1% ÷ ±3%
Dew point range for long-term tests +2 / +94 °C
Dew point range for short-term tests -20 / +2 °C
External dimensions (L x D x H) 1320 x 2235 x 2137 mm
Test space dimensions (L x D x H) 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per grid: 50 kg
Maximum floor load of the test chamber: 100 kg
Refrigerants: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your safety, the following information is provided as a buyer!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
Hnjdpfx Agowfddwocsk
3. Leakage test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Stress test chamber
EspecEHS-221MD
Call
Condition: excellent (used), Espec
Here we offer an Espec (ThermoTec) stress test chamber.
Outer dimensions: W x H x D: 860 x 1795 x 1000 mm
Hedpfx Agepdm Uyjconk
Test chamber dimensions W x H x D: 355 x 355 x 426 mm
2 x 46 l
Voltage 230 V 1/N 50 Hz
Rated current 37A
Fuses 250 V , 2 x 3 A
Type: EHS-221MD
Temperature range: + 105°C to + 142.9°C
Humidity range 75 to 100 % r.H.
Temperature constancy: -+ 0.5 °C
Pressure range: 0 to 2.0 kg/cm²
Heat-up or pressure build-up time: from 0 to 2.0 kg/cm² in about 60 minutes
390 kg
Condition: Used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Temperature chamber 2000 liters
CTST-40/2000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: T-40/2000
Air-cooled temperature test chamber
Technical design:
Refrigeration unit:
air-cooled, low-noise, fully hermetic, infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, door hinge left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 + 500 mm
Max. load per shelf 35 kg
Total load with max. grid load 100 kg
Test area lighting: 3x halogen lamp 20 W, 12 V
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoint values
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature range: -40°C to +180°C
Nominal voltage: 400V 3/N 50Hz
Rated power: 10.4 kW
Nominal current: 17.2 A
Compressor: TFH2516Z
Pipe feed-through NW 50
Control panel
Window 570x710 mm
Electrical connection, cable length 5m
Technical performance data:
Temperature tests:
Hnodpfjup T Uqsx Agcok
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 1.5 K/min
Heat radiation:
approx. 2500 W at +20°C
approx. 2100 W at ± 0°C
approx. 1500 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume: 2000 liters
Test chamber dimensions: Height 900, width 975, depth 2200 mm
External dimensions: Height 1950, width 1290, depth 3145 mm
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level (according to DIN EN ISO 3744
measured at a distance of 1 m from the front) < 55 dB(A)
Weight: approx. 1200 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Salt spray chamber corrosion test cabinet
VLMSAL 1000-FL PLC / V.715.362.520
Call
Condition: excellent (used), Type: SAL 1000-FL PLC / V.715.362.520
For sale is a used VLM Salt Spray Corrosion Test Chamber, type SAL 1000-FL PLC, ideal for industrial corrosion tests in accordance with international standards (DIN EN ISO 9227, ASTM B117). Perfectly suited for both laboratory and production environments to test materials, coatings, and components under controlled corrosive conditions.
Features:
- Robust stainless steel frame construction, max. load 450 kg
- Precise control and reproducible testing
- Versatile applications for salt spray, condensation water, and ventilation testing
Technical details:
- Exterior: Stainless steel 1.4301, powder-coated (special version)
- Test chamber: Stainless steel, ECTFE-coated
Hnsdpfoxnyqvjx Agcok
- Max. chamber temperature: +80 °C
- Temperature stability: ±0.3 °K, temporally ±0.1 °C
- Process control: PLC with touchscreen, LED display
- Interface: Ethernet
- Water quality: demineralized, max. conductivity 20 µS/cm
- Humidifier water consumption: approx. 0.5 l/h (depending on program)
- Water connection pressure: 2–4 bar
- Compressed air consumption: approx. 20 m³/h
- Compressed air connection: 6–8 bar
- External dimensions (W x D x H): 2160 x 670 x 1090 mm
incl. base cabinet: 2160 x 670 x 1890 mm
- Internal chamber dimensions (W x D x H) / volume: 1400 x 605 x 920 mm / 1040 l
- Max. load sample rod: 40 kg
- Electrical connection: 400 V / 50 Hz / 4000 W
- Weight (empty): 350 kg
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in technical data and specifications!)
For further questions, we are happy to assist you by phone.
Listing
Borken
1,034 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
Hnsdpfowxc I Uex Agcsk
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
For further questions, please feel free to contact us by phone.
Listing
Borken
1,034 km
Climate chamber with humidity 34 liters
WeissWKL 34/60 -60°C bis 150°C
Call
Condition: excellent (used), White
Type: WKL 34/60
Weiss air-cooled climate chamber
Refrigerant converted to R-452A
Hnjdpfx Ajtr Dinjgcok
-60°C to 150°C
Room volume: 34 liters
Entry port installed in basic equipment:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm Width 324 mm Depth 300 mmm
External dimensions: Height 1740 mm Width 630 mm Depth 970 mmm
Characteristic values for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation in space (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Characteristic values for climate tests:
Temperature range +10 to +95 °C
Humidity range 10 to 98 %r.H.
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation in space ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 %RH
Data for operation:
Test room lighting Halogen bulb 12V, 20W
Nominal voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
On-site fuse 16A slow-blow
Heat dissipation air-cooled test chambers
Max. Heat dissipation to surroundings 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Climate test chamber 280 liters
FeutronKPK 200 Typ: 3416/16 +5 °C bis +100 °C
Call
Condition: excellent (used), Here we offer a climatic test chamber.
Air cooled
Nominal test chamber volume: 280 liters
Hnsdpfx Ageiz Tqcscjk
Dimensions
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door disassembled: 1500 x 1940 x 925 mm
test chamber: 720 x 690 x 560 mm
door, clear width: 720 x 690 mm
viewing window, heated: 500 x 600 mm
Temperature range
+5 to +100 C
heating: 4,0 K /min
Cooling: 0.6 K /min
Climate range +10 to +95 C
Humidity range: 10 to 95 % r.H.
Humidity difference, temporal: ≤ ± 3.0
Water connection humidifier: city water or distilled water 20l reservoir tank.
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Power requirement max : 6,3 kW
Weight : 500 Kg
Type : 3416/16
Refrigerant : R134a
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Climate chamber Temp. and humidity
EspecPHP-J3 bis +100°C
Call
Condition: excellent (used), Espec
Type: PHP - J3
Technical data:
Air-cooled
Temperature and humidity range Room temperature +10°C to +100°C / 40 to 98% rel. LF
Temperature fluctuation ±0.3 K
Humidity fluctuation ±2.5%
Volume 398 liters
Dimensions:
Internal dimensions: Width 600 mm x height 830 mm x depth 800 mm
External dimensions: Width 1010 mm x height 1690 mm x depth 1273 mm
Mains voltage: 400 VAC 3∅ 50 Hz
Maximum current 400 VAC 8.3 A
Weight: 335 kg
Scope of delivery: Espec climatic test chamber
Hnjdpfx Ajtzbzcegcok
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Climate chamber Temp. and humidity
EspecPHP-J3 bis +100°C
Call
Condition: excellent (used), Espec
Type: PHP - J3
Technical data:
Air-cooled
Temperature and humidity range Room temperature +10°C to +100°C / 40 to 98% rel. LF
Temperature fluctuation ±0.3 K
Humidity fluctuation ±2.5%
Volume 398 liters
Dimensions:
Internal dimensions: Width 600 mm x height 830 mm x depth 800 mm
External dimensions: Width 1010 mm x height 1690 mm x depth 1273 mm
Mains voltage: 400 VAC 3∅ 50 Hz
Maximum current 400 VAC 8.3 A
Weight: 335 kg
Hsdpfx Aotzbz Aegcjnk
Scope of delivery: Espec climatic test chamber
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Temperature chamber TPK 200 280 liters
FeutronTyp: 3416/17 -70°C bis +180°C
Call
Condition: excellent (used), Here we offer a temperature test chamber.
Feutron temperature test chamber air-cooled
Nominal test chamber volume: 280 liters
Dimensions
Test chamber outside: width 1540 mm x height 2090 mm x depth 1240 mm
Fan motor and door removed: Width 1540 mm x height 1940 mm x depth 925 mm
Test chamber: Width 720 mm x height 690 mm x depth 560 mm
Door, clear width: width 720 mm x height 690 mm
Viewing window, heated: width 500 mm x height 600 mm
Installation dimensions of the temperature test chamber with open doors
Width 2340 mm x height 2090 mm x depth 2165 mm
Feed-through opening 2 side panels, left ∅ 100 mm
Temperature range
-70°C to +180°C
Hedpfoqxavaex Agcjnk
Heating: 3.0 K /min
Cooling: 3.0 K /min
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Max. power requirement: 6.3 kW
Weight: 635 kg
Type: 3416/17
Refrigerant: R507 / R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
Hodpfev N Hc Eex Agcenk
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Stress test chamber
Espec (ThermoTec)TPC-212D
Call
Condition: excellent (used), Espec
Type: TPC-212D
Technical Specifications
Test Procedure: HAST – Highly Accelerated Stress Test
Model: Espec TPC-212D
Internal Volume: 2x (approx. 22 liters)
Internal Dimensions (ø x L mm): 2x 295 x 330 mm
Temperature Range: +105 °C to +142.9 °C
Humidity Range: 75% to 100% RH
Pressure Range: 0.02 to 0.196 MPa gauge (0 to 28 psig)
Power Supply: 220 V (±5%), 1-Phase, 50/60 Hz, 20 A
Special Features: Two chambers in one device
Notes:
Hsdswl D Aaepfx Agcenk
Two chambers: Allow for simultaneous tests with different parameters or larger test volumes.
HAST test: Accelerated endurance test under high temperature and humidity
with overpressure for the qualification of electronic components.
Applications: Ideal for semiconductors, ICs, circuit boards, MEMS, etc.
Weight: 230 kg
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions over the phone.
Listing
Borken
1,034 km
Temperature chamber
WEISSWT11-1000/70/5
Call
Condition: excellent (used), Weiss temperature chamber
Here we offer a Weiss temperature chamber.
Weiss temperature chamber air cooled with Weiss condenser cooler
Test chamber capacity approx. 990 liters
Data for temperature tests:
Temperature range -70°C to +180°C
Temperature deviation in time in the center of the chamber ± 0.1 to ± 0.5 K
Temperature deviation spatially ± 0.5 to ± 2.0 K
Temperature gradient (acc. to IEC 60068-3-5) 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Hsdpfsp Dun Ajx Agcenk
Heating 5 K/min
Cooling 5 K/min
Heat compensation max. 2750 W
Feedthrough built into basic equipment
R1: NW 125 mm
L1: NW 50 m
Dimensions:
Test chamber dimensions: Width 1100 mm x depth 950 mm x height 950 mm
Housing dimensions: width 1390 mm x depth 1525 mm x height 1995 mm
maximum load (evenly distributed over the surface) of the test chamber floor 150 kg
per insert grate 50 kg
total load of the grate supports 100 kg
Data for operation:
Test room lighting halogen bulb 24V, 50W
Rated voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 27,0 kW
Rated current 42,02 A
Heat output water-cooled test chambers max. heat output to environment 1.3 kW
Noise measurement:
Sound pressure level approx. 64 dB(A)
Refrigerant: ( converted to R-452a )
weight: approx. 960 kg
Type: WT11-1000/70/5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. function check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Heraeus shock test chamber
Here we offer a shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
The temperature range of the warm chamber is from +50°C to +220°C.
Temperature deviation temporally in useful chamber center ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -65°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
For you as a buyer for safety the following information!
Hnjdpeikvlxjfx Agcok
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: HT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
1,034 km
Temperature chamber
ThermotronSE-1000-5-5
Call
Condition: excellent (used), Thermotron temperature chamber
Here we offer you a Thermotron temperature chamber.
Water cooled
Thermotron temperature chamber SE-1000-5-5
Dimensions of the working area - WxDxH: 102 x 100 x 97 centimeters
Working area volume: 986 liters
Temperature uniformity: ± 0,5°C
Temperature range: -70ºC to 180ºC
Temperature control tolerance: 0.3°C
Hnsdpeirmitefx Agcek
Infeed dimensions - WxDxH: 122 x 188 x 218 centimeters
Electrical requirements 400/3/50 32,4 A
Refrigerant: R-404A / R23
Approx. weight: 862 kg
Type: Thermotron SE- 1000-5-5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
1,034 km
Climate test chamber 900 liters
CTSCS-70/900 -70...+180°C
Call
Condition: used, Type: CS-70/900
CTS Climate Test Chamber with Humidity, water-cooled
Hnjdpfxjxb Dm Io Agcek
(converted to R-452a refrigerant)
Temperature range: -70°C to +180°C
Humidity range: 10–98% RH
Test chamber internal dimensions: Height approx. 870 mm / Width approx. 1000 mm / Depth approx. 1000 mm
External dimensions: Height approx. 1950 mm / Width approx. 1200 mm / Depth approx. 2220 mm
Control cabinet dimensions: Height approx. 2100 mm / Width approx. 800 mm / Depth approx. 400 mm
Test chamber volume: 900 liters
Refrigerant: R-452a / R23
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Connected load: 21.2 kW, Rated current: 35.7 A
Chamber weight: 900 kg
Control cabinet weight: 150 kg
Important safety information for buyers:
The following steps are carried out on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilled with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors reserved!)
For any further questions, please contact us by phone.
Listing
Borken
1,034 km
Corrosion testing device salt spray chamber
Gebr. LiebischS 1000 A-TR / 42016211
Call
Condition: excellent (used), Liebisch
Type: S 1000 A-TR / 42016211
Chest-mounted units with a 1000-liter test chamber volume for salt spray testing.
Constamatic® TR
This series includes automatically controlled chest-mounted units of type A-TR.
The internal controls are operated via a touchscreen.
Hsdpfswf Dh Njx Agcsnk
All functions are displayed on a touchscreen with intuitive user guidance.
Technical specifications:
Device type: S 1000 A-TR
External housing dimensions: (W x D x H in mm) 2600 x 1120 x 1210
Internal test chamber dimensions: (W x D x H in mm) 1535/1425 x 800/780 x 660/650
Max. sample holder load: 10 kg / level 10 kg
Operating voltage: 230 V +6/-10%
Power consumption S: 2700 W
Humidity control range. S: up to / 70°C
Test chamber control range K: up to / 50°C
Test chamber control range S: up to / 50°C
Frequency: 50/60 Hz
Device fuse: 12 A
Temperature control: PLC
Overtemperature protection: yes
Test chamber volume: 1000 liters
Test solution storage capacity: approx. / 150 liters
Test solution consumption per hour: approx. / 0.7 - 1.0 liters
Water filling of base pan KON: 15 liters
Weight: 450 kg
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Climatic test chamber shaker chamber 2160 liters
WeissWK3-2200/40/5/V -40°C bis +180°C
Call
Condition: excellent (used), Weiss
Type: WK3-2200/40/5/V
Weiss Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -40°C to +180°C
Temperature change rates:
Heating: 6.0 K/min
Cooling: 11.5 K/min
Temperature deviation:
Temporal ± 0.8 K
Spatial ± 2.0 K
Heat compensation max. 8000 W
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Dew point temperature range: +4°C to +94°C with closed floor element
Humidity range: 10 to 95% rH
Temperature deviation (temporal): ± 0.3 K
Humidity deviation (temporal): ± 3% rH
Temperature uniformity:
Spatial ± 1.0 K
Heat compensation max.: 500 W
Test chamber volume: 2,160 liters
Test chamber dimensions: Height 1,115 mm, Width 1,400 mm, Depth 1,400 mm
External dimensions (lowered): Height 2,318 mm, Width 1,860 mm, Depth 3,658 mm
External dimensions above shaker: Height 2,710 mm
External dimensions max. stroke height: 3,038 mm
Exchangeable floor dimensions: Width 1,600 mm, Depth 1,504 mm
Operating Data:
Hnjdew I Rxrjpfx Agcek
Rated voltage: 3/N/PE AC 400V +10% 50Hz
Rated power: 38.0 kW
Rated current: 63.0 A
Customer-side fuse: 80 A slow-blow
Refrigerant: R 404A
Weight: approx. 2,100 kg
Important information for your safety as a buyer:
The following points will be carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with refrigerant compliant with legal regulations
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
We are happy to answer any further questions you may have by phone.
We make it easier for you to find: "cts klimaschrank walk-in temperature and humidity test chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month




























































































































































































































































