Used Heraeus Vötsch Heraeus Vötsch for sale (158)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch VCS³ 7034-5 Climatic Test Chamber / Temperature Test Chamber -70°C to +180°C, 335 L, 5 K/min
VötschVCS³ 7034-5
Call
Condition: used, Vötsch
Climate testing chamber / temperature testing chamber
Vötsch VCS³ 7034-5 climate testing chamber
Water-cooled
With a temperature change rate of 5 K/min
For sale is a used climate testing chamber
from the manufacturer Vötsch Industrietechnik GmbH.
The testing chamber is suitable for temperature and climate tests,
environmental simulation, material testing, quality assurance,
as well as development and stress tests.
Technical data:
Manufacturer: Vötsch Industrietechnik GmbH
Type: VCS³ 7034-5
Equipment type: Climate testing chamber / temperature testing chamber
Test chamber volume: approx. 335 liters
External dimensions: Width 870 x Depth 1700 x Height 1775 mm
Test chamber dimensions: Width 580 x Depth 765 x Height 750 mm
Weight: approx. 570 kg
Temperature range: -70 °C to +180 °C
Temperature change rate, heating: approx. 7.0 K/min
Temperature change rate, cooling: approx. 8.0 K/min
Max. heat compensation: 3000 W at +20 °C / 3000 W at -20 °C
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature homogeneity spatially: ±0.5 to ±2.0 K
Climate range, temperature: +10 °C to +95 °C
Dew point range: +4 °C to +94 °C (extended to -3 °C, intermittently)
Humidity range: 10 to 98 % RH
Humidity deviation: ±1 to ±3 % RH
Refrigerant: R404A / R-23
Refrigerant quantity: R404A 2.5 kg / R-23 0.75 kg
ND max.: 21 bar(g)
HD max.: 25 bar(g)
Power connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 9 kW
Rated current: 20 A
On-site protection: 63 A slow-blow fuse
Itedpfxsz Akcfe Akpon
Equipment:
S!MPAC control system
Touch panel operation
Interior made of stainless steel
Temperature and humidity control
Ethernet interface
USB interface
Cable entry 50 mm
Cable entry 125 mm
Test specimen protection function
Accessories as shown in the pictures
Application areas:
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Condition:
Used
Visual condition as shown in the pictures
Scope of delivery:
1x Vötsch VCS³ 7034-5 climate testing chamber
Accessories as shown in the pictures
Important note:
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful check
Shipping or freight forwarding possible.
Subject to changes, errors and prior sale.
We will gladly answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
1,027 km
Heraeus Xenotest 1200 CPS weathering tester weathering test chamber
HeraeusXenotest 1200 CPS
Call
Operating hours: 3,888 h, condition: good (used), Heraeus Weathering Test Device Xenotest 1200 CPS
Xenon device for testing the lightfastness and weathering resistance of materials under simulated conditions.
Rapid exposure device with program control and radiation control.
The Xenotest 1200 CPS is equipped with:
3 Xenon lamps NXE 4500
Optional filter system
Microprocessor control including data display
Simultaneous or alternating/simultaneous operation function
Humidity function
Spraying function
Electrical connection
Voltage: 400 V
Rated current: 50 A max.
Connection power: 33 kVA max.
Power consumption of the xenon lamps: 2.8 - 6 kW per lamp
Compensation: 3 capacitors at 50 uF
Itjdpfx Akjxal Haepjn
Operating hours: 3888
Housing dimensions: W x H x D 900 x 1900 x 1700 mm
Weight: 800 kg
More items – new and used – can be found in our shop!
International shipping costs available upon request!
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch VCS³ 7034-5 Climatic Test Chamber / Temperature Test Chamber -70°C to +180°C, 335 L, 5 K/min
VötschVCS³ 7034-5
Call
Condition: used, Vötsch
Climate testing chamber / Temperature testing chamber
Vötsch VCS³ 7034-5 Climate testing chamber
Water-cooled
With a temperature change rate of 5 K/min
For sale is a used climate testing chamber
from the manufacturer Vötsch Industrietechnik GmbH.
The testing chamber is suitable for temperature and climate tests,
environmental simulation, material testing, quality assurance,
as well as development and stress tests.
Technical data:
Manufacturer: Vötsch Industrietechnik GmbH
Type: VCS³ 7034-5
Device type: Climate testing chamber / Temperature testing chamber
Test chamber volume: approx. 335 liters
External dimensions: Width 870 x Depth 1700 x Height 1775 mm
Test chamber dimensions: Width 580 x Depth 765 x Height 750 mm
Weight: approx. 570 kg
Temperature range: -70 °C to +180 °C
Temperature change rate (heating): approx. 7.0 K/min
Temperature change rate (cooling): approx. 6.7 K/min
Max. heat compensation: 3000 W at +20 °C / 3000 W at -20 °C
Temperature deviation (time): ±0.1 to ±0.5 K
Temperature homogeneity (spatial): ±0.5 to ±2.0 K
Climate range (temperature): +10 °C to +95 °C
Dew point range: +4 °C to +94 °C (extended to -3 °C, intermittent)
Humidity range: 10 to 98 % RH
Humidity deviation: ±1 to ±3 % RH
Refrigerant: R404A / R-23
Refrigerant quantity: R404A 2.5 kg / R-23 0.75 kg
ND max.: 21 bar(g)
HD max.: 25 bar(g)
Power connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 9 kW
Rated current: 20 A
On-site protection: 63 A slow-blow fuse
Equipment:
Iedpfxozpihao Akpotn
S!MPAC control system
Touch panel operation
Stainless steel interior
Temperature and humidity control
Ethernet interface
USB interface
Cable gland 50 mm
Cable gland 125 mm
Test object protection function
Accessories as shown in the pictures
Application areas:
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Condition:
Used
Optical condition as shown in the pictures
Scope of delivery:
1x Vötsch VCS³ 7034-5 Climate testing chamber
Accessories as shown in the pictures
Important note:
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if necessary
3. Leak test with certificate
4. Documented test run after successful inspection
The table shown in the photos and any other items not explicitly mentioned
are not included in the sale.
Shipping or freight forwarding possible.
Subject to change, errors and prior sale.
We are happy to answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch VTS³ 7160-5 H temperature test chamber -70/+180°C, 1568 liters
VötschVTS³ 7160-5 H
Call
Condition: used, Vötsch
Temperature testing chamber
VTS³ 7160-5 H
Water-cooled
For sale is a used temperature testing chamber from the manufacturer Vötsch.
The testing chamber is suitable for temperature and climate testing,
environmental simulation, material testing, quality assurance,
as well as development and stress testing.
Technical data
Manufacturer: Vötsch
Type: VTS³ 7160-5 H
Device type: Temperature testing chamber
Test chamber volume: approx. 1568 liters
Test chamber dimensions: approx. 1100 x 950 x 1498 mm (W x D x H)
Housing dimensions: approx. 1300 x 2635 x 2013 mm (W x D x H)
Weight: approx. 1700 kg
Temperature range: -70 °C to +180 °C
Temperature change rate, heating: approx. 5 K/min
Temperature change rate, cooling: approx. 4 K/min
Max. heat compensation: approx. 5000 W
Temperature deviation over time: ± 0.1 to ± 0.5 K
Itodpfozv S Hfjx Akpon
Temperature homogeneity spatially: ± 0.1 to ± 2.0 K
Refrigerant: R404A
Refrigerant quantity: 5.20 kg
ND max.: 18 bar g
HD max.: 25 bar g
Refrigerant: R23A
Refrigerant quantity: 1.30 kg
ND max.: 18 bar g
HD max.: 25 bar g
Cooling water consumption at full load with
temperature difference Dt = 10 K: 2.2 m3/h
temperature difference Dt = 5 K: 4.4 m3/h
Mains connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 17.6 kW
Rated current: 32 A
Equipment
Touch panel operation
Interior made of stainless steel
Side openings
Test chamber equipment as shown in the pictures
Application areas
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Condition
Used
Optical condition as shown in the pictures
Scope of delivery
1x Vötsch VTS³ 7160-5 H temperature testing chamber
Important note:
For the safety of our customers, the following work is carried out on the offered climate chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
Shipping or freight shipping possible.
Subject to changes, errors and prior sale.
We will gladly answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch VC³ 7018 climate test chamber / temperature chamber -70°C to +180°C, humidity, 190 liters
VötschVC³ 7018
Call
Condition: used, Vötsch
Climate testing chamber / Temperature testing chamber
Vötsch VC³ 7018 Climate testing chamber
Temperature and climate testing chamber, air-cooled
For sale is a used climate testing chamber from Vötsch Industrietechnik GmbH.
The testing chamber is suitable for temperature and climate testing, environmental simulation, material testing, quality assurance, as well as development and stress tests.
Technical data
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC³ 7018
Device type: Climate testing chamber / Temperature testing chamber
Test chamber volume: approx. 190 liters
Dimensions (approx.): Width: 870 mm, Depth: 1,550 mm, Height: 1,800 mm
Test chamber dimensions: Width: 580 mm, Depth: 450 mm, Height: 750 mm
Weight: approx. 460 kg
Itodpszm Ni Eefx Akpjn
Temperature range: -70 °C to +180 °C
Temperature change rate (heating): approx. 4 K/min
Temperature change rate (cooling): approx. 3 K/min
Max. heat compensation: approx. 1,500 W
Temperature deviation (time-related): ± 0.1 to ± 0.3 K
Climate range (temperature): +10 °C to +95 °C
Humidity range: 10 to 98 % RH
Refrigerant 1: R404A
Refrigerant quantity: 2.5 kg
ND max.: 22.5 bar g
HD max.: 25 bar g
Refrigerant 2: R23
Refrigerant quantity: 0.75 kg
ND max.: 22.5 bar g
HD max.: 25 bar g
Mains connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 4.9 kW
Rated current: 16 A
Equipment
Touch panel control
Programmable controller
Stainless steel interior
Temperature and humidity control
LAN/Ethernet interface
Viewing window with internal lighting
Documentation / Operating manual
Test reports
Accessories as shown in the pictures
Application areas
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Condition
Used
Workshop-checked
Moisture absorber replaced
Optical condition as shown in the pictures
Scope of delivery
1x Vötsch VC³ 7018 climate testing chamber
Documentation / Operating manual
Test reports
Accessories as shown in the pictures
Important note:
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if necessary
3. Leak test with certificate
4. Documented test run after successful inspection
The table shown in the photos, as well as any other items not explicitly mentioned, are not included in the sale.
Shipping or freight forwarding possible.
Subject to changes, errors and prior sale.
We will be happy to answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
1,027 km
Vötsch VTR 7033/S Temperature Test Chamber -70°C to +180°C Climate Test Chamber TK07
VötschVTR 7033/S
Call
Condition: good (used), Year of construction: 1996, Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature chamber
Temperature range: -70°C to +180°C
Supply voltage: 400V
Rated current: 24A
Rated power: 9.5 kW
Refrigerant (high-temperature): R 404 A
Refrigerant (low-temperature): R 23
Year of manufacture: 1996
TK 07
You can find more new and used items in our shop!
International shipping costs available upon request!
Ijdpfx Aewbpzmokpotn
Success:
Your message has been sent.
Listing
Borken
1,027 km
Vötsch VC 0150 Climate Test Chamber Temperature Test Chamber +90°C Humidity 10% - 98% KK09
VötschVC 0150
Call
Condition: excellent (used), Vötsch VC 0150 Climate Test Chamber 0°C - +90°C
Manufacturer: Vötsch
Type: VC 0150
Climate test chamber
Voltage: 230 V
Rated power: 1.5 kW
Volume: 1540 liters
Temperature range: 0°C to +90°C
Humidity: 10% to 98%
Refrigerant: R 134a
Dimensions: W 950 x D 1100 x H 1475 mm
Microprocessor controller
List price: €19,500
KK-09
You can find more new and used items in our shop!
International shipping costs available upon request!
Iedpsuuikfefx Akpstn
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch drying oven / heat cabinet / heating oven Vötsch NTU 60/60 250°C (80118)
VötschNTU 60/60
Call
Condition: used, Vötsch
Ijdpfxjzdiyhe Akpstn
Type: NTU 60/60
Rated temperature: 250°C
Connection voltage:
400 V 3 (N) PE AC, 50/60 Hz
Internal dimensions: Width 600 mm, Height 600 mm, Depth 600 mm
External dimensions: Width 1000 mm, Height 1675 mm, Depth 1300 mm
Forced air circulation fan
Scope of delivery: (See image)
(Subject to changes and errors in the technical data and specifications!)
We would be happy to answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch climate test chamber VCS³ 7027-10, -72°C to +180°C with humidity control, 270 liters capacity
VötschVCS³ 7027-10
Call
Condition: used, Vötsch
Iedpjzh Huujfx Akpetn
Type: VCS³ 7027-10
Vötsch climate testing chamber, water-cooled
With a temperature change rate of 10 K/min
Data for temperature testing:
Temperature range: -72°C to +180°C
Temporal temperature deviation in the center of the usable space: ± 0.3 K to ± 0.5 K
Spatial temperature deviation: ± 0.5 K to ± 2.0 K
Temperature change rate
Heating: 10 K/min
Cooling: 14.5 K/min
Data for climate testing:
Temperature range: +10°C to +95°C
(extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
Temporal temperature deviation in the center of the usable space: ± 0.2 K to ± 0.3 K
Spatial temperature deviation: ± 0.5 K to ± 1.0 K
Temporal humidity deviation in the center of the usable space: ± 1% to ± 3% RH
Humidity range: 10% to 98% RH
(extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
External dimensions: Width 780 x Depth 1895 x Height 1775 (mm)
Test chamber dimensions: Width 580 x Depth 615 x Height 750 (mm)
Test chamber volume: approx. 270 liters
Side opening: 50 mm
Side opening: 125 mm
Data for operation:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ± 10%, 50 Hz
Rated power: 14 kW Rated current: 26 A
Fuse, on customer’s side: 63 A, slow-blow
Refrigerant: R404A/R-23
Weight approx. 835 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch temperature testing chamber with spray device -30 to 80°C, 500 liters, VBT 03/500
VötschVBT 03/500
Call
Condition: used, Vötsch
Type: VBT 03/500
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Temperature deviation in the stabilized state
according to IEC 60068-3-5, depending on the test chamber temperature
time-based ± 1 K
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the support grid.
Water level = 0 mm
The water level is at the upper edge of the support grid.
Data for spray device, standard
Number of spray nozzles 6
Spray volume per nozzle 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles 6
Spray volume per nozzle 4.5 l/min
Additional flooding nozzles 2
Spray volume additional nozzle 6 l/min
Compressed air consumption approx. 3 m³/h
Data for water tank with preheating
Volume approx. 2000 l
Temperature range for preheating +5°C to +40°C
Temperature change duration
Cooling from +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Data for installation and operation:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Feedthroughs
1 feedthrough ∅ 50 mm installed on the left
Test chamber volume: approx. 500 liters
Refrigerant R-404a
Electrical connection:
Rated voltage 3/N/PE AC 400V ± 10% 50Hz
Rated power approx. 26 kW
Rated current approx. 44.0 A (neutral conductor loaded)
Fuse 63 A gG, on customer's side
Weight approx. 890 kg net
For your safety as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Iedszh D S Rspfx Akpjtn
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch climate test chamber VCS³ 7034-5 -70°C to +180°C with humidity control, 335 liters
VötschVCS³ 7034-5
Call
Condition: used, Vötsch
Type: VCS³ 7034-5
Vötsch Climate Testing Chamber, Water-Cooled
With a temperature change rate of 5 K/min
Data for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ± 0.1 K to ± 0.5 K
Spatial temperature deviation: ± 0.5 K to ± 2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Data for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ± 0.1 K to ± 0.3 K
Spatial temperature deviation: ± 0.5 K to ± 1.0 K
Temporal humidity deviation in the center of the usable space: ± 1% to ± 3% RH
Humidity range: 10% to 98% RH
(extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
External dimensions: Width 870 x Depth 1700 x Height 1775 (mm)
Test chamber dimensions: Width 580 x Depth 765 x Height 750 (mm)
Test chamber volume: approx. 335 liters
Side opening: 50 mm
Side opening: 125 mm
Data for operation:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10 %, 50 Hz
Rated power: 9 kW, Rated current: 20 A
Fuse, on customer's side: 63 A slow-blow
Refrigerant: R404A/R-23
Weight: approx. 570 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Itjdpfx Akeziyx Nopon
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch Shock Test Chamber VT 7012 S3, temperature range -80°C to +220°C
VötschTemperaturschrank VT 7012 S3
Call
Condition: used, Vötsch
Type: VT 7012 S3
Vötsch Shock Test Chamber
Water-cooled
Temperature range: -80°C to +220°C
Warm chamber: +50 to +220°C
Medium chamber: -10 to +90°C
Cold chamber: -80 to +70°C
Supply voltage: 400V ±10% 3/N 50Hz
Rated current: 30.5 A
Rated power: 13.5 kW
Itedpfx Akezd Uzuspsn
Refrigerant VK: R 404A 3.00 kg p*: 25 bar
Refrigerant TK: R23 15 bar p*: 25 bar
For your safety as a buyer, please note the following:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch VC³ 0034 climate test chamber, temperature test chamber, 335L, 10-98% RH
VötschVC³ 0034
Call
Condition: used, Vötsch
Climate test chamber / Temperature test chamber
Vötsch VC³ 0034 Climate test chamber
Temperature and climate test chamber, air-cooled
For sale is a used climate test chamber
from the manufacturer Vötsch Industrietechnik GmbH.
The test chamber is suitable for temperature and climate tests,
environmental simulation, material testing, quality assurance,
as well as development and stress tests.
Technical data
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC³ 0034
Equipment type: Climate test chamber / Temperature test chamber
Test chamber volume: approx. 335 liters
Test chamber dimensions: approx. 580 x 765 x 750 mm (W x D x H)
Housing dimensions: approx. 875 x 1860 x 1805 mm (W x D x H)
Weight: approx. 490 kg
Temperature range: -10 °C to +90 °C
Temperature change rate, heating: approx. 1 K/min
Temperature change rate, cooling: approx. 0.3 K/min
Max. heat compensation: approx. 200 W
Temperature deviation over time: ± 0.1 to ± 0.5 K
Temperature homogeneity in space: ± 0.5 to ± 1 K
Climate range, temperature: +10 °C to +90 °C
Dew point range: +4 °C to +89.5 °C
Humidity range: 10 to 98 % RH
Refrigerant: R404A
Refrigerant quantity: 0.6 kg
ND max.: 25 bar g
HD max.: 25 bar g
Power connection: 1/N/PE AC 230 V ±10 % / 50 Hz
Rated power: 2.3 kW
Rated current: 10 A
Water tank: 20 liters
Protection class: IP54
Noise level: approx. 46 dB(A)
Equipment
SIMPAC control
Touch panel operation
Interior made of stainless steel
Temperature and humidity control
Ethernet interface
USB interface
RS232 interface
RS485 / RS422 interface
Test specimen protection function
Cable glands
Documentation / Operating manual
Accessories according to images
Areas of application
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Condition
Used
Optical condition according to images
Scope of delivery
1x Vötsch VC³ 0034 Climate test chamber
Documentation / Operating manual
Accessories as shown in the images
Important note:
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
The table shown in the photos or other items not explicitly mentioned
are not part of the sale.
Shipping or freight forwarding possible.
Subject to change, errors and prior sale.
Iedpfx Ajzgb Awskpstn
We will gladly answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch VC 4060 climate test chamber / temperature test chamber, 600L, -40°C to +180°C with humidity
VötschVC 4060
Call
Condition: used, Vötsch
Climate test chamber / temperature test chamber
Vötsch VC 4060 climate test chamber
Temperature and climate test chamber with humidity, water-cooled
(converted to R-452a)
For sale is a used climate test chamber from Vötsch Industrietechnik GmbH.
The test chamber is suitable for temperature and climate tests, environmental simulation, material testing, quality assurance, as well as development and stress tests.
Technical data
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC 4060
Equipment type: Climate test chamber / temperature test chamber
Test chamber volume: approx. 600 liters
Controller: S!MCON / 32
Test chamber dimensions: approx. 800 x 800 x 950 mm (W x D x H)
Housing dimensions: approx. 1090 x 1960 x 1995 mm (W x D x H)
Weight: approx. 600 kg net
Temperature range: -40 °C to +180 °C
Temperature change rate, heating: approx. 4.0 K/min
Temperature change rate, cooling: approx. 3.0 K/min
Temperature deviation, temporal: ±0.1 to ±0.5 K
Temperature deviation, spatial: ±0.5 to ±2 K
Temperature gradient: approx. 1 to 4 K
Climate range, temperature: -10 °C to +95 °C
Humidity range: 10 % to 98 % RH
Humidity deviation: ±0.1 to ±3 % RH
Temperature deviation, climate operation, temporal: ±0.1 to ±0.3 K
Temperature deviation, climate operation, spatial: ±0.5 to ±1.0 K
Temperature gradient, climate operation: approx. 1 to 2 K
Refrigerant: R452A
Cooling: water-cooled
Rated voltage: 3/N/PE AC 400 V ±10 % 50 Hz
Rated power: 7.8 kW
Rated current: 15.0 A
Fuse: 16 A slow-blow, provided by the customer
1 penetration Ø 50 mm, installed on the left
1 penetration Ø 125 mm, installed on the right
Test chamber made of stainless steel
Touch panel operation
Equipment
S!MCON / 32 controller
Touch panel operation
Viewing window in the door
Interior made of stainless steel
Test chamber lighting
Side penetrations Ø 50 mm and Ø 125 mm
Shelving / test chamber equipment as shown in the pictures
Water-cooled system
Documentation / operating manual
Accessories as shown in the pictures
Areas of application
Itodpfx Aozf E E Tokpsn
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Condition
Used
Optical condition as shown in the pictures
Scope of delivery
1x Vötsch VC 4060 climate test chamber
Documentation / operating manual
Accessories as shown in the pictures
Important note:
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
The table shown in the photos, as well as any other items not explicitly mentioned, are not included in the sale.
Shipping or forwarding by a freight carrier is possible.
Subject to changes, errors and prior sale.
We will be happy to answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch Thermal Shock Test Chamber VT³ 7006 S2 -50°C to +220°C / -80°C to +70°C, 60 liters
VötschVT³ 7006 S2
Call
Condition: used, Vötsch
Type: VT³ 7006 S2-M
Air-cooled
Technical data:
Test specimen weight max. 20 kg
Test volume: 60 liters
Test chamber dimensions: width 380 mm, depth 430 mm, height 370 mm
External dimensions: width 875 mm, depth 1970 mm, height 1895 mm
Vertical arrangement of hot and cold chambers (chamber change via moving platform)
Temperature range of the hot chamber: +50 °C to +220 °C (calibration value +125 °C)
Temperature range of the cold chamber: -80 °C to +70 °C (calibration value -40 °C)
Uniform temperature distribution in the test chamber (±0.5 K to ±2.0 K)
Temperature deviation over time: ±0.3 K to ±1.0 K
80 mm pipe passage for measurement / supply of the test specimen
Software SIMCONTROL for operation and status display
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 8.5 kW Rated current: 25 A
Itjdpfjzima Hsx Akpen
Refrigerant R-404A R-23
Weight approx. 800 kg
For your safety as a buyer, please note the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch VC³ 4018/S Climate Test Chamber for Li-Ion CO/CO₂, −42 to +150 °C, 400 V, 190 liters
VötschVC³ 4018/S
Call
Condition: used, Vötsch
Type: VC³ 4018/S
Vötsch VC³ 4018/S Climate Test Chamber, Li-Ion, CO/CO₂
-42 to +150 °C, 400 V, Air-cooled
For sale is a temperature and climate test chamber from the renowned German manufacturer Vötsch Industrietechnik GmbH, type VC³ 4018/S, manufactured in 2012.
The unit is specifically equipped for testing lithium-ion batteries and features CO monitoring and CO₂ inertization to enhance operational safety.
Important Note:
Due to this safety equipment, the test chamber is software-limited to a temperature range of -42 °C to +150 °C.
The chamber is ideally suited for:
Li-Ion battery tests
Electronics and component testing
Temperature and climate stress tests
Development and quality assurance tasks
Technical Data:
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Iedpfxjzimfvo Akpetn
Test chamber volume: 190 liters
Feedthrough installed as standard equipment
R1: ® 125 mm
L1: © 50 mm
Data for temperature tests:
Temperature range: -42 °C to +150 °C
Temperature deviation over time: ± 0.1 to ± 0.5 K
Temperature homogeneity in space: ± 0.5 to ± 1.5 K
Temperature change rate
Heating: 4 K/min
Cooling: 4 K/min
Max. heat compensation: 2300 W
Data for climate tests:
Temperature range: +10 to +95 °C
Dew point range: -3 to +94 °C
Humidity range: 10 to 98 % RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature homogeneity in space: ± 0.5 to ± K
Humidity deviation over time: ± 1 to ± 3 % RH
Heat compensation: 400 W
Data for operation:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
3/N/PE AC 400V ± 10% 50 Hz
Rated power: 4.1 kW
Rated current: 14 A
Refrigerant: R-404A
Weight: 470 kg
For your safety as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch climate test chamber VC 4034, temperature range -40°C to +180°C, 335 liters
VötschVC 4034
Call
Condition: used, Vötsch
Climate testing chamber / Temperature testing chamber
Vötsch VC 4034 Climate testing chamber
Temperature and climate testing chamber, air-cooled
Itodpfx Ajzd Dm Hokpen
Converted to R452A
For sale is a used climate testing chamber
from the manufacturer Vötsch Industrietechnik GmbH.
The testing chamber is suitable for temperature and climate tests,
environmental simulation, material testing, quality assurance,
as well as development and stress tests.
Technical data
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC 4034
Equipment type: Climate testing chamber / Temperature testing chamber
Test chamber volume: approx. 335 liters
Test chamber dimensions: approx. 580 x 765 x 750 mm (W x D x H)
Housing dimensions: approx. 780 x 1758 x 1800 mm (W x D x H)
Weight: approx. 515 kg net
Temperature range: -40 °C to +180 °C
Temperature change rate, heating: approx. 3.2 K/min
Temperature change rate, cooling: approx. 3.5 K/min
Temperature deviation over time: ± 0.1 to ± 0.5 K
Temperature homogeneity, spatially: ± 0.5 to ± 1.5 K
Climate range, temperature: -40 °C to +180 °C
Humidity range: 10 % to 98 % RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatially: ± 0.5 to ± 1.0 K
Refrigerant: R452A
Refrigerant quantity: 2.5 kg
Maximum suction pressure: 22 bar g
Maximum discharge pressure: 25 bar g
Mains connection: 3/N/PE AC 400 V +10 % / 50 Hz
Rated power: 4.1 kW
Rated current: 12.5 A
Equipment
Touch panel operation
Viewing window in the door
Stainless steel interior
Test chamber lighting
Side feedthrough
Insert grid
Air-cooled system
Documentation / Operating manual
Accessories according to the pictures
Application areas
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Condition
Used
Optical condition according to the pictures
Scope of delivery
1x Vötsch VC 4034 Climate testing chamber
Insert grid
Control panel / controller
Documentation / Documents
Accessories according to the pictures
Important note:
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
Shipping or freight shipping possible.
Subject to changes, errors and prior sale.
We will gladly answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch Temperature Test Chamber VTS³ 7018-5, 190 liters, -70°C to +180°C
VötschTemperaturprüfschrank VTS³ 7018-5
Call
Condition: used, Vötsch
Type: VTS³ 7018-5
Temperature test cabinet, water-cooled
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 900 mm x Depth 1550 mm x Height 1850 mm
Temperature testing:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Temperature change rate: Cooling 7.5 K/min
Test chamber volume: 190 liters
Rated voltage: 400V
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Refrigerant: R404A and R23
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Ijdpfezfg Ucjx Akpjtn
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch climate test chamber VCS 7034-5, -70°C to +180°C, 335 liters, with humidity control
VötschKlimaprüfschrank
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climate test chamber
Test chamber volume: 335 liters
Performance for temperature tests
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4
Rate of change:
Cooling: 3.5 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration values: +23°C and +80°C
Performance for climate tests
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580mm, Depth 765mm, Height 750mm
External dimensions: Width 870mm, Depth 1595mm, Height 1775mm
1 Feedthrough, approx. 50 mm diameter, left
2 Feedthrough, approx. 125 mm diameter, left
1 Feedthrough, approx. 125 mm diameter, right
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R404A / R-23
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Itjdozizl Dspfx Akpon
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We are happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Győr
1,926 km
Temperature test chamber -72°C to +180°C
VötschVTS 7060-5 600 Liter
Call
Year of construction: 2016, operating hours: 14,242 h, condition: excellent (used), Vötsch temperature test chamber, water-cooled
Itodjt Txqrspfx Akpen
Here we offer you a Vötsch temperature test chamber.
Vötsch 7060-5 water-cooled chanber
Test chamber dimensions: Height: 950 mm, width: 800 mm, depth: 800 mm
External dimensions: Height 1995 mm, width: 1090 mm, depth: 1960 mm
Test chamber capacity: approx. 600 liters
Year of construction: 2016
Operational hours: 14 242
Entry ports:
R1: NW 125 mm
L1: NW 50 mm
Data for temperature tests:
Temperature range: -72°C to +180°C
Temperature deviation in time in the center of the usable space ± 0.1 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 2.0 K
Temperature change rate
Heating 6.0 K/min
Cooling 6.0 K/min
Heat compensation at 20°C max. 5000 W
Heat compensation at -20°C max. 5000 W
Electrical connection:
Rated voltage: 3/NPE AC 400V ±10% 50Hz
Rated power: 13,0 kW Rated current: 23.0 A
Refrigerant: R-404A and R-23
Weight (approx.): 650 kg
The following information is for your safety as a buyer!
1. The chamber works perfectly.
2. No components have to be replaced.
3. Refrigerant is filled with legally compliant.
Condition: used (excellent)
(Changes and errors in the technical data, specifications are reserved!)
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch shock test chamber +50°C to +220°C / -80°C to +70°C VT 7012 S2
VötschSchocktestkammer
Call
Condition: used, Vötsch
Type: VT 7012 S2
Water-cooled version
Vötsch temperature shock test chamber / environmental simulation system
Model: VT 7012 S2
Two-chamber system (hot / cold chamber)
For sale is a high-quality Vötsch temperature shock test chamber
for rapid temperature change tests in industry, research, and development.
The device is in used condition.
See pictures for optical condition.
Control panel and observation window are included.
Temperature data:
Hot chamber: +50 °C to +220 °C
Cold chamber: -80 °C to +70 °C
Temperature deviation over time: ±1 K
Itjdpfxjy Iyuwj Akpjn
Temperature deviation spatially: ±2 K
Heating rate hot chamber: approx. 11 K/min
Heating rate cold chamber: approx. 2 K/min
Cooling rate cold chamber: approx. 3 K/min
Test chamber:
Test chamber volume: approx. 125 liters
Internal dimensions: approx. 470 x 650 x 410 mm
Cable entry: Ø approx. 67 mm
Dimensions:
External dimensions: approx. 930 x 2115 x 1970 mm
Electrical data:
Mains connection: 3/N/PE AC 400 V ±10% / 50 Hz
Rated power: approx. 10 kW
Rated current: approx. 25 A
Refrigerant according to nameplate:
R404A: 2.9 kg
R23: 1.27 kg
Operating pressure ND: max. 22.5 bar
Operating pressure HD: max. 25 bar
Weight: approx. 1000 kg
Equipment / Features:
Two-chamber shock test system
Rapid temperature change testing
Digital control / display
Program operation
Observation window
Cable entry
Water-cooled version
For your safety as a buyer, the following information:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Scope of delivery:
Vötsch VT 7012 S2 temperature shock test chamber
Scope of delivery as shown in the pictures
Condition & Notes:
Condition: used
Inspection possible by arrangement
Loading can be organized
(Changes and errors in technical data are subject to change!)
We would be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Success:
Your message has been sent.
Listing
Siegendorf
1,848 km
Vötsch VT 7100
VötschVT 7100
Call
Year of construction: 1999, condition: used, We offer this used Vötsch VT 7100 climate chamber, year of manufacture 1999.
Device number: 59566005700010
Year of manufacture: 1999
Refrigerant: R 404A
Itodpfxeyu Hwqe Akpen
Refrigerant charge: 4.2 kg
Permissible operating overpressure: 25 bar
Stand pressure: 70 bar
Voltage: 3/N/PE AC 400 V ±10 % 50 Hz
Rated output: 11.5 kW
Rated current: 22.0 A
Wiring diagram no.: EPL 66912
System diagram no.: RPL 67612041W
If you have any questions or need further information, please feel free to send us a message or call us.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch Climate Test Chamber VC 7018 Temperature Range -70°C to +180°C with Humidity Control, 190 Lit
VötschKlimaprüfschrank
Call
Condition: used, Vötsch
Type: VC 7018
Vötsch Climate Testing Chamber VC 7018, Water-Cooled
Control Panel: “Touch Panel”
All control and operating commands can be initiated by simply touching the function symbols on the “Touch Panel” control panel.
Adjustable Feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine, the testing chamber is equipped with adjustable feet.
Feedthroughs
The testing chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the testing chamber.
Feedthroughs installed as standard:
R1: 125 mm
L1: 50 mm
Itodpfezh Huhsx Akpsn
Testing chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Performance data for temperature tests:
Temperature range: -70°C to +180°C
Temporal: ±0.1 to ±0.5 K
Spatial: ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min.
Cooling: 2.3 K/min.
Performance data for climate tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% RH
Temporal temperature deviation in the center of the usable space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Temporal humidity deviation in the center of the usable space: ±1 to ±3 % RH
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10 50Hz
Rated power: 5.9 kW
Rated current: 12.0 A
Connection cable: 3.5 m
Fuse: 16 A, slow-blow, provided on site
Refrigerant: R-404A and R-23
Testing chamber volume: approx. 190 liters
Weight: approx. 460 kg net
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
1,034 km
Vötsch temperature test chamber, 190 liters, temperature range -70°C to +180°C, model VTS 7018-5.
VötschVTS 7018-5
Call
Condition: used, Vötsch
Type: VTS 7018-5
Water-cooled temperature test chamber
System converted to R-452A
Itodpfx Asziixxekpon
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 7.5 K/min
Temperature change rate (heating): 7.5 K/min
Thermal compensation at +20°C: 3000 W
Thermal compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 100 kW, Rated current: 21 A
Fuse, on customer side: 32 A, slow-blow
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side feed-through: 50 cm / 125 cm
Chamber is water-cooled
Refrigerant: R-452A and R23
Weight: approx. 460 kg
For your safety as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
1,027 km
Vötsch VCS 4100 Climate Test Chamber -40 °C to +180 °C Temperature Test Cabinet KK07
VötschVCS 4100
Call
Condition: good (used), Vötsch VCS 4100 climate testing chamber, -40 °C to +180 °C
Manufacturer: Vötsch
Type: VCS 4100
Isdpfsuuiygex Akpetn
Temperature range: -40 °C to +180 °C
Supply voltage: 400 V
Rated current: 17 A
Rated power: 11 kW
Refrigerant: R404A
KK-07
You can find more items – new and used – in our shop! International shipping costs available upon request!
We make it easier for you to find: "heraeus vötsch heraeus vötsch"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you