Used Vötsch Vtr 7033/S for sale (68,870)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Győr
1,926 km
Temperature test chamber -72°C to +180°C
VötschVTS 7060-5 600 Liter
Call
Year of construction: 2016, operating hours: 14,242 h, condition: excellent (used), Vötsch temperature test chamber, water-cooled
Here we offer you a Vötsch temperature test chamber.
Vötsch 7060-5 water-cooled chanber
Test chamber dimensions: Height: 950 mm, width: 800 mm, depth: 800 mm
External dimensions: Height 1995 mm, width: 1090 mm, depth: 1960 mm
Test chamber capacity: approx. 600 liters
Year of construction: 2016
Operational hours: 14 242
Entry ports:
R1: NW 125 mm
L1: NW 50 mm
Data for temperature tests:
Temperature range: -72°C to +180°C
Temperature deviation in time in the center of the usable space ± 0.1 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 2.0 K
Temperature change rate
Heating 6.0 K/min
Cooling 6.0 K/min
Heat compensation at 20°C max. 5000 W
Heat compensation at -20°C max. 5000 W
Electrical connection:
Rated voltage: 3/NPE AC 400V ±10% 50Hz
Rated power: 13,0 kW Rated current: 23.0 A
Ksdet Txqrspfx Adqjdr
Refrigerant: R-404A and R-23
Weight (approx.): 650 kg
The following information is for your safety as a buyer!
1. The chamber works perfectly.
2. No components have to be replaced.
3. Refrigerant is filled with legally compliant.
Condition: used (excellent)
(Changes and errors in the technical data, specifications are reserved!)
Listing
Borken
1,034 km
Climate test chamber C 340 liters, year 2018
Vötschtechnik ClimeEventC/340/70/5/S -70°C bis +180°C
Call
Year of construction: 2018, condition: excellent (used), VÖTSCH ClimeEvent C/340/70/5/S Climate Test Chamber
Manufacturer: Vötsch Industrietechnik GmbH
Type: ClimeEvent C/340/70/5/S
Year of Manufacture: 2018
Machine Type: Climate Test Chamber / Temperature and Humidity Test Chamber
Test Chamber Volume: approx. 340 liters
For sale is a used VÖTSCH ClimeEvent C/340/70/5/S
climate and temperature test chamber with three side-mounted,
telescopically extendable test drawers.
The test chamber was developed for professional temperature, climate,
humidity, aging, and stress tests and is ideal for testing laboratories,
the automotive and electronics industries, research institutions, and
quality assurance.
Technical data:
Model: ClimeEvent C/340/70/5/S
Test chamber volume: approx. 340 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rate: approx. 5 K/min
Power supply: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 9 kW
Rated current: 20 A
Refrigerant: R449A
Refrigerant quantity R449A: 2.50 kg
Additional refrigerant: R23
Refrigerant quantity R23: 0.75 kg
Max. low pressure: 21 bar g
Max. high pressure: 25 bar g
Static pressure R23: 13 bar g
Test drawers:
3 telescopically extendable test drawers
Stainless steel grid baskets for holding test specimens
Separately lockable, insulated drawer fronts
Heated drawer openings
Individual test levels accessible separately
Suitable for holding several small components and assemblies
Dimensions:
External dimensions (H × W × D): approx. 1,800 × 895 × 1,810 mm
Test chamber dimensions (H × W × D): approx. 750 × 580 × 765 mm
Weight: approx. 650 kg
Equipment:
WEBSeason touch operating panel
Digital measurement and control system
Temperature and humidity control
3 telescopic test drawers
Stainless steel grid inserts
Observation window
Side cable and test specimen openings
Donaldson Ultrafilter compressed air treatment
S!MPATI software license
Calibration certificate
Quality test certificate
EU declaration of conformity
Documentation / operating manual
Accessories as shown in the pictures
Application areas:
Temperature testing
Climate testing
Humidity testing
Environmental simulation
Material testing
Electronics and component testing
Aging and stress testing
Automotive industry
Research and development
Quality assurance
Transport data:
Transport dimensions (H × W × D): approx. 1,800 × 895 × 1,810 mm
Electrical connection: 400 V / 50 Hz / 20 A
Weight: approx. 650 kg
Condition:
Used
Optical condition as shown in the pictures.
Scope of delivery:
VÖTSCH ClimeEvent C/340/70/5/S climate test chamber
3 telescopic test drawers with grid inserts
Donaldson Ultrafilter
S!MPATI software documents
Calibration and quality documentation
Operating manual / technical documentation
Accessories as shown in the pictures
Shipping or freight shipping possible.
Kdodpfx Adszp Inroqer
Scope of delivery as shown in the pictures.
Subject to changes, errors and prior sale.
Listing
Borken
1,034 km
Large-capacity oven
VötschOfen NTUD 125/130/125 50 bis 150°C
Call
Condition: used, Vötsch
Type: NTUD 125/130/125
Pass-through oven
Last maintenance: 3.12.25
Temperature control in 3 zones:
Control of the internal temperature via an electronic temperature control system, divided into 3 separate temperature zones and controlled by semiconductor switching devices. This ensures good temperature uniformity whether operating in fresh or recirculated air mode.
Temperature program control:
The CTC control system is operated via a dialog PC with TSI software for the heating control of each temperature zone, as well as the activation of the recirculation fans and damper control.
Horizontal airflow with reversal:
By switching the electronically or pneumatically actuated dampers, the airflow direction can be set from left to right or right to left. The airflow direction for each of the 3 zones can be independently adjusted.
Vertical airflow:
By shifting a cover plate in the oven ceiling.
Useful floor area:
The floor area can be driven on using customer-provided loading trolleys.
Recirculation fans:
Each zone is equipped with a radial fan.
Usable space dimensions: 1300 mm height / 1250 mm width / 1250 mm depth
External dimensions: 2490 mm height / 1770 mm width / 1810 mm depth
Volume: 2000 liters
Connection rating: 400V(N)PE AC 50/60 Hz 22 kVA
Rated current: 32 A
Power: 18 kW
Nominal temperature: 50 to 150°C
Weight: 1000 kg
Condition: used
Scope of delivery: (See photo)
Kdjdpfxsy H Akre Adqjr
(Specifications and data subject to change and errors excepted!)
We are happy to answer any further questions by phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
1,027 km
Temperature shock test chamber -70-220°C
VötschVT 7012 S2
Call
Year of construction: 2000, operating hours: 104,382 h, condition: excellent (used), Vötsch Shock Test Chamber VT 7012 S2
System for extreme temperature cycling
Temperature shock testing is used to test the resistance of components, devices, and other products to rapid changes in ambient temperature.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
These cyclical stresses and the accelerated aging caused by temperature changes reveal weaknesses in the test specimen.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the car
Cart load capacity 50 kg for VT3 7012 S2
All-around grilles in the car secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
Hot chamber can be used as a temperature storage unit, cold chamber as a temperature exchange unit
Minimal energy consumption
No compressed air required
Manufacturer: Vötsch
Type: VT 7012 S2
Type: Temperature shock test chamber
Kdedpfox Exmtox Adqor
Test chamber volume: 120 l
Nominal voltage: 400 V
Nominal power: 10 kW
Nominal current: 25 A
Refrigerant: R452A
Cooling unit: Water-cooled
Shock cooling (nitrogen cooling) via customer-supplied nitrogen
External dimensions
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class
Device: IP 42
Operating panel: IP 20
Control cabinet: IP 54
Temperature test parameters for single-chamber operation |
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class ...Temperatur Temperature range
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: ±2 K
in steady state
Temperature deviation over space: ±2 K
in steady state in the car
Heating rate, hot chamber: 11 K/min
Cooling rate, cold chamber: K/min
Heating rate, cold chamber: 2 K/min
Cooling rate, hot chamber: K/min
Observation window: 355 x 355 mm
Pipe opening: 67 mm
Year of manufacture: 2000
Operating hours: 104,382
Weight: 1000 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items – new and used – can be found in our shop! International shipping costs on request!
Listing
Borken
1,032 km
Vötsch climatic test chamber Fitotron HGC1014
Vötsch Klimaprüfschrank 5°C bis +45°Fitotron HGC 1014 V Schrank 3 mit Bel.
Call
Condition: excellent (used), functionality: fully functional, Year of construction: 2012, Fitotron® Modular Plant Growth Chambers, Type HGC 1014 V, including HQI-T and Krypton Lighting Module
Temperature range +5°C - +45°C for temperature testing
Test chamber volume approx. 1300 l
Simpac Control System
Network Connection
USB Connection
The Fitotron® HGC series plant growth chambers are based on a modular design. Individual modules can be added or replaced as needed. This allows them to be adapted to different applications. They are suitable for plants with high light requirements, such as wheat, corn, cotton, rice, and C4 plants.
Lighting HQI-BT-400 W/D and 100 W,
Temperature range +5°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% RH approx. 0.8 kW
Characteristics for climatic tests with irradiation
Temperature range +10°C to +45°C with light on +10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Humidification and dehumidification system, stainless steel test chamber
Internal dimensions: Height 1400 mm, Depth 750 mm, Width 1270 mm
External dimensions: Height 1985 mm, Depth 980 mm, Width 2320 mm
External dimensions with lighting module: Height 2450 mm
Single door with observation window
Interface for computer connection
Connection 3/N/PE 400V ±10% 50Hz
Kdedpfxevz U Erj Adqjr
CE marking, mobile, very good condition
Pipe penetration ∅ 50 mm
Air cooling
Refrigerant R404A
Weight approx. 480 kg + 130 kg lighting module
Listing
Borken
1,034 km
Temperature shock test chamber -80°C to +220°C
VötschVT³ 7012 S2 125 Liter
Call
Condition: excellent (used), Vötsch VT³ 7012 S2 Temperature Shock Chamber
Manufacturer: Vötsch Industrietechnik GmbH
Type: VT³ 7012 S2
Machine Type: Temperature Shock Chamber
Test Chamber Volume: 125 liters
Offered is a used Vötsch VT³ 7012 S2 temperature shock chamber for rapid temperature changes and environmental simulation tests.
The system is suitable, among other things, for electronics, component, material, and assembly testing, quality assurance, research and development, as well as aging and stress tests.
Technical Data:
Temperature Range, Hot Zone: +50 °C to +220 °C
Temperature Range, Cold Zone: -80 °C to +70 °C
Test Chamber Volume: 125 liters
Max. Load: 50 kg
Cooling: Water-cooled
Refrigerant 1: R404A
Refrigerant Quantity: 1.70 kg
Max. Low Pressure: 22.5 bar g
Max. High Pressure: 25 bar g
Refrigerant 2: R23
Refrigerant Quantity: 1.27 kg
Max. Low Pressure: 22.5 bar g
Max. High Pressure: 25 bar g
Standby Pressure: 14 bar g
Power Connection: 3/N/PE AC 400 V +10 % / 50 Hz
Rated Power: 10 kW
Rated Current: 25 A
Dimensions:
Test Chamber Dimensions (W × D × H): 470 × 650 × 410 mm
External Dimensions (W × D × H): 970 × 2350 × 2450 mm
Equipment:
Kdsdpoztwk Rsfx Adqor
Programmable Touch Panel Control
Two Temperature Zones
Water-Cooled Refrigeration System
Observation Window
Test Chamber Lighting
Temperature Display
Status Display
Test Item Holder / Transfer Basket
Test Item Feed-Through
Accessories as Shown in Pictures
Shipping Information:
External Dimensions: 970 × 2350 × 2450 mm (W × D × H)
Weight: 1000 kg
Shipping by freight forwarder possible.
Condition:
Used
Optical Condition as Shown in Pictures
Nameplate Present
Scope of Delivery:
1 × Vötsch VT³ 7012 S2 Temperature Shock Chamber
Programmable Touch Panel
Accessories as Shown in Pictures
For the safety of our customers, the following work will be carried out on the offered testing and climate systems in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
The device is available.
Scope of delivery as shown in the pictures.
Subject to changes, errors and prior sale.
Listing
Borken
1,034 km
Temperature test chamber 335 liters
VötschVTS 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Heraeus Vötsch Temperature Test Chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 5.0 K/min
Temperature change rate (heating): 6.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test chamber volume: 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW, Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Side feedthrough: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R 452A and R 23
Kodpszd R Tgjfx Adqodr
Weight: approx. 570 kg
Type: VTS 7034-5
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have on the phone.
Listing
Borken
1,034 km
Temperature test chamber spray device
VötschVBT 03/500 500 Liter -30 bis 80°C
Call
Condition: excellent (used), Vötsch
Type: VBT 03/500
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Temperature deviation in the stabilized state
according to IEC 60068-3-5, depending on the test chamber temperature
± 1 K over time
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the support grid
Water level = 0 mm
The water level is at the top edge of the support grid
Data for spray device, standard
Number of spray nozzles 6
Spray volume per nozzle 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles 6
Spray volume per nozzle 4.5 l/min
Additional flooding nozzles 2
Spray volume additional nozzle 6 l/min
Compressed air consumption approx. 3 m³/h
Data for water tank with preheating
Volume approx. 2000 l
Temperature range for preheating +5°C to +40°C
Temperature change duration
Cooling from +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Data for installation and operation:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Feedthroughs
1 feedthrough ∅ 50 mm, installed on the left
Test chamber volume: approx. 500 liters
Refrigerant R-404a
Electrical connection:
Rated voltage 3/N/PE AC 400V ± 10% 50Hz
Rated power approx. 26 kW
Rated current approx. 44.0 A (neutral conductor loaded)
Fuse 63 A gG, on-site
Weight approx. 890 kg net
For your safety as a buyer, the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
Kdodpezh D S Rsfx Adqsr
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Climate test chamber 335 liters 10-98% relative humidity.
VötschVC³ 0034 -10 °C bis +90 °C
Call
Condition: excellent (used), Vötsch VC³ 0034 Climate Test Chamber
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC³ 0034
Kdedpfx Adezgb Aweqer
Machine Type: Climate Test Chamber / Climate Chamber
Test Chamber Volume: approx. 335 liters
For sale is a used climate test chamber from Vötsch for temperature and climate testing in laboratories, research, development, and quality assurance.
Technical Data
Test Chamber Dimensions: approx. 580 x 765 x 750 mm (W x D x H)
Housing Dimensions: approx. 875 x 1860 x 1805 mm (W x D x H)
Temperature Range: -10 °C to +90 °C
Humidity Range: 10 to 98 % RH
Dew Point Range: +4 °C to +89.5 °C
Temperature Homogeneity: ±0.5 to ±1 K
Temperature Deviation: ±0.1 to ±0.5 K
Heating Rate: approx. 1 K/min
Cooling Rate: approx. 0.3 K/min
Max. Heat Compensation: approx. 200 W
Refrigerant: R404A
Filling Quantity: 0.6 kg
ND max.: 25 bar g
HD max.: 25 bar g
Power Connection: 230 V / 50 Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Protection Class: IP54
Weight: approx. 490 kg
Equipment
SIMPAC control system
Temperature and humidity control
Stainless steel test chamber
Ethernet, USB, RS232, RS485/422
Test item protection function
Cable glands
Application Areas
Climate testing
Temperature testing
Material testing
Electronics testing
Quality assurance
Research and development
Scope of Supply
Vötsch VC³ 0034 Climate Test Chamber
Accessories as shown in the pictures
Condition
Used
Optical condition as shown in the pictures
For the safety of our customers, the offered climate chambers are tested before delivery,
if necessary, filled with legally compliant refrigerant, subjected to a leak test,
and delivered with a documented test run.
Subject to change and errors in technical data as well as prior sale.
Listing
Borken
1,034 km
-50°C to +220°C, -80 to +70°C, 60 liters
VötschVT³ 7006 S2 Temperaturschockschrank
Call
Condition: excellent (used), Vötsch
Type: VT³ 7006 S2-M
Water-cooled
Technical Specifications:
Maximum specimen weight: 20 kg
Test chamber volume: 60 liters
Test chamber internal dimensions: Width 380 mm, Depth 430 mm, Height 370 mm
External dimensions: Width 875 mm, Depth 1970 mm, Height 1895 mm
Vertical arrangement of hot and cold chambers (chamber change via lift carriage)
Temperature range of hot chamber: +50 °C to +220 °C (calibration value +125 °C)
Temperature range of cold chamber: -80 °C to +70 °C (calibration value -40 °C)
Kjdezima Hepfx Adqedr
Uniform temperature distribution in the test chamber (±0.5 K to ±2.0 K)
Temporal temperature deviation: ±0.3 K to ±1.0 K
80 mm duct for measurement/supply connections to the specimen
SIMCONTROL software for operation and status display
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power: 8.5 kW
Rated current: 25 A
Refrigerants: R-404A, R-23
Weight: approx. 800 kg
Important information for your safety as a buyer!
The following points are carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if required
3. Leak test with certificate
4. Following successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Specifications and information subject to change or error!)
Should you have any further questions, we are happy to answer them by phone.
Listing
Borken
1,034 km
Climate test chamber with humidity, 190 liters
VötschVC³ 7018 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch VC³ 7018 Climate Testing Chamber
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC³ 7018
Machine Type: Climate Testing Chamber / Temperature Testing Chamber
Test Chamber Volume: approx. 190 liters
For sale is a used Vötsch VC³ 7018 climate testing chamber
for performing temperature and climate tests.
The unit is suitable for environmental simulation, material testing,
quality assurance, electronics testing, and research and development.
Before delivery, the device was inspected in our workshop,
the heating, cooling, and humidity functions were tested, and the humidity wick was replaced.
Technical Data:
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC³ 7018
Test Chamber Volume: approx. 190 liters
Test Chamber Dimensions (W × D × H): approx. 580 × 450 × 750 mm
External Dimensions (W × D × H): approx. 875 × 1,545 × 1,805 mm
Weight: approx. 460 kg
Temperature Range: -70 °C to +180 °C
Temperature Change Rate (Heating): approx. 4 K/min
Temperature Change Rate (Cooling): approx. 3 K/min
Humidity Range: 10 to 98 % RH
Climate Range: +10 °C to +95 °C
Power Connection: 3/N/PE AC 400 V / 50 Hz
Rated Power: 4.9 kW
Rated Current: 14 A
Refrigerant: R404A (2.5 kg)
Refrigerant: R23 (0.75 kg)
Operating Hours: 35,800.6 h
Equipment:
Touch Panel Control
Programmable Controller
Temperature and Humidity Control
Stainless Steel Test Chamber
Viewing Window with Interior Lighting
LAN/Ethernet Interface
Air-Cooled Refrigeration System
Test Protocols
Operating Manual
Accessories as shown in the pictures
Application Areas:
Temperature Testing
Climate Testing
Environmental Simulation
Material Testing
Electronics Testing
Quality Assurance
Research and Development
Condition:
Used
Workshop Checked
Optical condition as shown in the pictures.
Scope of Delivery:
Kdsdpfszm Ni Eox Adqor
Vötsch VC³ 7018 Climate Testing Chamber
Test Protocols
Operating Manual
Accessories as shown in the pictures
Availability: by arrangement.
Scope of delivery as shown in the pictures.
Subject to change, errors and prior sale.
Listing
Borken
1,034 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Type: VCS 7034-5
Climate Test Chamber Water-Cooled
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature deviation spatially: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 3.5 K/min
Kedpozizl Dsfx Adqsdr
Heating: 6.8 K/min
Heat compensation at +20°C: 3,000 W / at -20°C: 3,000 W
Temperature calibration points: +23°C and +80°C
Performance for climate tests:
Temperature range: +10 to +95°C
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Humidity deviation over time: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climatic calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions:
Width: 580 mm, Depth: 765 mm, Height: 750 mm
External dimensions:
Width: 870 mm, Depth: 1595 mm, Height: 1775 mm
Feedthroughs:
1 x approx. 50 mm Ø, left side
2 x approx. 125 mm Ø, left side
1 x approx. 125 mm Ø, right side
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R404A / R-23
For your security as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and errors!)
If you have further questions, we are happy to answer them by phone.
Listing
Borken
1,034 km
Climatic test chamber -70°C to +180°C
VötschVCS 7034-5 - 335 Liter
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climate test chamber
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Time-related temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4
Rate of change:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration values: +23°C and +80°C
Performance for climate tests:
Temperature range: +10 to +95°C
Time-related temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-related humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580mm, Depth 765mm, Height 750mm
External dimensions: Width 870mm, Depth 1595mm, Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Kdedpfozg Tx Rox Adqer
Cooling water consumption: 1.4 m³/h
Refrigerant: R-404A / R-23
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions by telephone.
Listing
Borken
1,034 km
Shock test chamber
VötschVT 7012 S3
Call
Condition: excellent (used), Vötsch Shock Test Chamber
Kdodpfxezd Uzue Adqer
Here we offer you a Vötsch shock test chamber.
Water-cooled
Temperature range: -80°C to +220°C
Warm chamber: +50 to +220
Intermediate chamber: -10 to +90
Cold chamber: -80 to +70
Supply voltage: 400V ±10% 3/N 50Hz
Rated current: 30.5 A
Rated power: 13.5 kW
Refrigerant VK: R 404A 3.00 kg p*: 25 bar
Refrigerant TK: R23 15 bar p*: 25 bar
Condition: used
Type: VT 7012 S3
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Borken
1,034 km
Special version for leather testing
Vötsch KlimaprüfschrankVC³ 4018-M -40°C bis +180°C
Call
Condition: excellent (used), Vötsch VC³ 4018-M climate testing chamber for leather goods, -40 °C to +180 °C, 190 l, 10–98 % RH, Vaisala and SIMPATI®
Modified special version for leather testing
Temperature range: -40 °C to +180 °C
Test chamber volume: approx. 190 liters
Humidity range: 10–98 % RH
Cooling: water-cooled
For sale is a used Vötsch VC³ 4018-M climate and temperature testing chamber with humidity function.
The device is suitable for temperature and climate testing, environmental simulation, material testing,
quality assurance, as well as development and stress tests.
Special version "-M":
The model suffix "-M" designates a modified version for testing leather and leather goods.
Extended climate range up to +120 °C at 10 % RH.
Capacitive Vaisala humidity measuring system
Compressed air connection / GN2 K3000
3.5-inch touch panel instead of the standard 8-inch panel
Touch panel in the test chamber door
Technical data:
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC³ 4018-M
Test chamber (W × D × H): approx. 580 × 450 × 750 mm
External dimensions (W × D × H): approx. 870 × 1,550 × 1,800 mm
Weight: approx. 470 kg
Heating: approx. 4 K/min
Cooling: approx. 4 K/min
Max. heat compensation: approx. 2,300 W
Temperature deviation: ±0.1 to ±0.5 K
Temperature homogeneity: ±0.5 to ±1.5 K
Climate data:
Standard climate range: +10 °C to +95 °C
Dew point range: -3 °C to +94 °C
Humidity deviation: ±1 to ±3 % RH
Heat compensation, climate operation: approx. 400 W
Special climate range for leather testing: up to +120 °C at 10 % RH
Refrigeration and connection data:
Refrigerant: R404A, filling quantity: 1.6 kg
ND max.: 22.5 bar g, HD max.: 25 bar g
Power connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 4.1 kW, rated current: 14 A
Equipment:
3.5-inch ControlPad
Vaisala humidity measuring system
Compressed air connection / GN2 K3000
Connection for demineralized water
Viewing window and stainless steel test chamber
Test chamber lighting 2 × 24 V / 50 W
Kdodezna N Eopfx Adqer
Cable glands Ø 125 mm and Ø 50 mm
3 insert racks
SIMPATI® software version 2016 with 2 device licenses
Certificate of authenticity and original operating manual
Test documents and accessories as shown in the pictures
Condition and scope of delivery:
Used,
optical condition as shown in the pictures.
Scope of delivery: Vötsch VC³ 4018-M, 3 insert racks, operating manual, SIMPATI® license documents,
certificate of authenticity
Accessories as shown in the pictures.
Items not explicitly mentioned are not included in the offer.
Shipping by freight forwarder possible by arrangement.
Subject to change, errors and prior sale.
Listing
Borken
1,034 km
With moisture 270 liters
VötschKlimaprüfschrank VCS³ 7027-10
Call
Condition: excellent (used), Vötsch
Type: VCS³ 7027-10
Vötsch Climate Test Chamber, Water-Cooled
With a temperature change rate of 10 K/min
Data for temperature testing:
Temperature range: -72°C to +180°C
Temporal temperature deviation in the center of the usable space: ± 0.3 K to ± 0.5 K
Spatial temperature deviation: ± 0.5 K to ± 2.0 K
Temperature change rate:
Heating: 10 K/min
Cooling: 14.5 K/min
Data for climate testing:
Temperature range: +10°C to +95°C
(extended climate range: 2°C/95% relative humidity, regulated for max. 2 hours)
Temporal temperature deviation in the center of the usable space: ± 0.2 K to ± 0.3 K
Spatial temperature deviation: ± 0.5 K to ± 1.0 K
Temporal humidity deviation in the center of the usable space: ± 1% to ± 3% relative humidity
Humidity range: 10% to 98% relative humidity
(extended climate range: 2°C/95% relative humidity, regulated for max. 2 hours)
External dimensions: Width 780 x Depth 1895 x Height 1775 (mm)
Test chamber dimensions: Width 580 x Depth 615 x Height 750 (mm)
Test chamber volume: approx. 270 liters
Side opening: 50 mm
Side opening: 125 mm
Data for operation:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Nominal voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Nominal power: 14 kW Nominal current: 26 A
Fuse, on customer’s side: 63 A, slow-blow
Refrigerant: R404A/R-23
Kedpfx Aszh Huujdqedr
Weight: approx. 835 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature Range: -70°C to +180°C
Temporal Temperature Deviation: ± 0.1 to ± 0.5 K
Spatial Temperature Deviation: ± 0.5 to ± 2.0 K
Temperature Change Rate (Cooling): 5.0 K/min
Temperature Change Rate (Heating): 6.5 K/min
Thermal Compensation at +20°C: 3000 W
Thermal Compensation at -20°C: 3000 W
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test Chamber Volume: 335 liters
Rated Voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated Power: 10 kW, Rated Current: 21 A
Sound Level at 1m Distance (Free Field Measurement): < 69dB (A)
Side Access: 5.5 cm / 12.5 cm
Chamber is water-cooled
Kjdpfx Aszg Tpisdqjdr
Refrigerant: R-404A and R-23
Weight: approx. 570 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. Refilling with refrigerants compliant with legal regulations
3. After successful inspection, the chambers undergo a test run, which is monitored with calibrated equipment.
Condition: used
Scope of Supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
1,034 km
Temperature cabinet
VötschVTS 7011-5
Call
Condition: good (used), Vötsch
Type: VTS 7011-5
Heraeus Vötsch temperature control chamber, water-cooled
Test chamber volume: 110 liters
Test chamber dimensions: width 560 mm, depth 350 mm, height 630 mm
External dimensions: width 850 mm, depth 1030 mm, height 1640 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.3 to 1 K
Kedpfx Adozg Tpcsqedr
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate (cooling): 6 K/min
Temperature change rate (heating): 10 K/min
Refrigerant: R-404 A / R 23
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 7.5 kW
Rated current: 13 A
Weight: 360 kg
For your security as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We are happy to answer any further questions you may have by telephone.
Listing
Borken
1,034 km
Temperature test chamber 270 liters
VötschVTS³ 7027-25 -72°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7027-25
Heraeus Vötsch temperature testing chamber, water-cooled
Performance data:
With a temperature change rate of 25 K/min
Test chamber dimensions: height 750 mm, width 580 mm, depth 615 mm
External dimensions: height 1775 mm, width 780 mm, depth 1895 mm
Temperature range: -72°C to +180°C
Temperature deviation (over time): ± 0.1 to ± 0.5
Temperature homogeneity (spatial): ± 0.5 to ± 2.0
Temperature change rate (cooling): 25 K/min
Temperature change rate (heating): 25 K/min
Heat compensation at -20°C: 8000 W
Heat compensation at +20°C: 8000 W
Test volume: 270 liters
2x side ports, diameter 125 cm
1x side port, diameter 50 cm
Chamber is water-cooled
Test chamber lighting:
LED strip 24 V, 6.8 W / 2x halogen bulb 24 V, 50 W
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 26 KW
Rated current: 44 A
Refrigerant: R-452A and R-23
Kdsdpjzg Eygefx Adqsr
Weight: approx. 980 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data and specifications are reserved!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
1,034 km
Temperature test chamber
VötschVTS³ 7018-5
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7018-5
Water-cooled
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 900 mm x Depth 1550 mm x Height 1850 mm
Temperature testing:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Temperature change rate: Cooling 7.5 K/min
Test chamber volume: 190 liters
Rated voltage: 400 V
Kedszfg Ucspfx Adqodr
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Refrigerant: R404A and R23
For your safety as a buyer, please note the following information:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are reserved!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
1,034 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
Kodpjzg Twgefx Adqedr
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
1,034 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature Range: -70°C to +180°C
Temperature Deviation (temporal): ±0.1 to ±0.5 K
Temperature Deviation (spatial): ±0.5 to ±2.0 K
Temperature Change Rate (cooling): 5.0 K/min
Temperature Change Rate (heating): 6.5 K/min
Heat Compensation at +20°C: 3000 W
Heat Compensation at -20°C: 3000 W
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test Chamber Volume: 335 liters
Rated Voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated Power: 10 kW, Rated Current: 21 A
Sound Level at 1m Distance (Free-Field Measurement): < 69dB (A)
Side Feedthrough: 5.5 cm / 12.5 cm
Chamber is water-cooled.
Refrigerant: R-404A and R-23
Weight: approx. 570 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components.
2. New filling with legally compliant refrigerant.
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of Delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We are happy to answer any further questions you may have by phone.
Kodszg Tp Nepfx Adqedr
Listing
Borken
1,034 km
Climate test chamber 335 liters with humidity
VötschVCS³ 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VCS³ 7034-5
Vötsch Climate Test Chamber, Water-Cooled
With temperature change rate of 5 K/min
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.5 K
Spatial temperature deviation: ±0.5 K to ±2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.3 K
Spatial temperature deviation: ±0.5 K to ±1.0 K
Temporal humidity deviation in the center of the usable space: ±1% to ±3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH regulated for a maximum of 2 hours)
Exterior dimensions (W x D x H): 870 x 1700 x 1775 mm
Test chamber dimensions (W x D x H): 580 x 765 x 750 mm
Test chamber volume: approx. 335 liters
Kdjdpfx Aeziyx Nodqor
Side ports: 50 mm and 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulbs 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Rated power: 9 kW Rated current: 20 A
Customer-side fuse: 63 A slow-blow
Refrigerant: R404A / R-23
Weight approx. 570 kg
For your security as a buyer, please note the following:
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and errors!)
Further questions can be answered by phone.
Listing
Borken
1,034 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch Temperature Shock Testing Chamber
Type: VT 7012 S2
Manufacturer: Vötsch Industrietechnik GmbH
Design: Water-cooled
Kdedey Iyuwspfx Adqer
For sale is a two-chamber temperature shock testing chamber from Vötsch, designed for rapid temperature change tests. Suitable for industrial, automotive, aerospace, as well as research and development applications.
Temperature Ranges:
Hot Chamber: +50 °C to +220 °C
Cold Chamber: -80 °C to +70 °C
Temperature Data:
Temporal temperature deviation: ±1 K
Spatial temperature deviation: ±2 K
Heating rate, hot chamber: approx. 11 K/min
Heating rate, cold chamber: approx. 2 K/min
Cooling rate: approx. 3 K/min
Test Chamber:
Volume: approx. 125 liters
Internal dimensions: approx. 470 x 650 x 410 mm
Cable entry: Ø 67 mm
Electrical Data:
Connection: 3/N/PE AC 400 V ±10% / 50 Hz
Rated power: approx. 10 kW
Rated current: approx. 25 A
Refrigerant:
R404A: 2.9 kg
R23: 1.27 kg
Pressure Data:
ND max.: 22.5 bar
HD max.: 25 bar
Dimensions:
approx. 930 x 2115 x 1970 mm
Weight:
approx. 1000 kg
Equipment:
Two-chamber shock testing system
Digital control
Program operation
Observation window
Cable entry
Condition:
Used
Optical condition as shown in the pictures
Normal storage and usage marks present
Scope of delivery:
Vötsch VT 7012 S2 temperature shock testing chamber
Accessories as shown in the pictures
Important Note:
All information has been provided to the best of our knowledge based on the pictures, nameplates, and manufacturer information.
Shipping is possible.
Subject to changes, errors and prior sale.
We are happy to answer any further questions by phone.
Listing
Borken
1,034 km
Climate test chamber with humidity, 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
Kdedpfx Adszh Huhsqjr
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
We make it easier for you to find: "vötsch vtr 7033/s"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month



































































































































































































































































