With 2x AI AS 1310 autosamplersThermo Fisher Scientific
Flash 2000 CHNS O Analyzer
With 2x AI AS 1310 autosamplers
Thermo Fisher Scientific
Flash 2000 CHNS O Analyzer
Fixed price plus VAT
€6,500
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- With 2x AI AS 1310 autosamplers
- Manufacturer:
- Thermo Fisher Scientific
- Condition:
- excellent (used)
Price & Location
Fixed price plus VAT
€6,500
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A21755313
- Reference number:
- 25147
- Update:
- 20.04.2026
Description
Thermo Fisher Scientific Flash 2000 CHNS O Analyzer with 2 x AI AS 1310 Autosamplers
For sale is a used Thermo Fisher Scientific Flash 2000 elemental analyzer. The unit is equipped with two AI AS 1310 autosamplers and is designed for automated laboratory operations.
This system is used for elemental analysis in laboratory settings. Sample introduction is managed via the installed autosamplers, allowing for continuous and automated operation.
Equipment and Configuration
- Thermo Fisher Scientific Flash 2000
- CHNS O Analyzer
- 2 x AI AS 1310 Autosamplers
- Front display with status indicators for operational states
- Gas connections for He and O2
- RS232 interface and additional device interfaces
Ijdpfxey D Sqvj Amlstf
- Connections for autosamplers and optional modules
- Power supply: 230 V
- Accessories and parts as shown in the images
Technical Data
Manufacturer: Thermo Fisher Scientific
Model: Flash 2000
Device type: Elemental analyzer
Voltage: 230 V AC
Frequency: 50/60 Hz
Fuses: 2 x 6 A
Power consumption: 1400 VA
Autosamplers
Model: AI AS 1310
Supply voltage: 24 V DC
Power: 46 W per unit
Serial numbers: 420126446 and 420126487
Dimensions
Main unit width: approx. 55 to 60 cm
Depth: approx. 55 to 65 cm
Height: approx. 50 to 60 cm
Total width with 2 autosamplers: approx. 100 to 120 cm
Weight
Main unit: approx. 45 to 60 kg
Each autosampler: approx. 8 to 12 kg
Total: approx. 60 to 80 kg
Condition
Used, with age- and usage-related signs of wear. Condition as shown in the images.
Scope of delivery
- Flash 2000 Analyzer
- 2 x Autosamplers
- Accessories and cables as shown
Notes
- The table shown in the photos is not included in the sale
- All information is taken from the nameplate or the device shown
- Subject to errors and prior sale
- We are happy to answer any questions you may have.
The listing was translated automatically. Translation errors are possible.
For sale is a used Thermo Fisher Scientific Flash 2000 elemental analyzer. The unit is equipped with two AI AS 1310 autosamplers and is designed for automated laboratory operations.
This system is used for elemental analysis in laboratory settings. Sample introduction is managed via the installed autosamplers, allowing for continuous and automated operation.
Equipment and Configuration
- Thermo Fisher Scientific Flash 2000
- CHNS O Analyzer
- 2 x AI AS 1310 Autosamplers
- Front display with status indicators for operational states
- Gas connections for He and O2
- RS232 interface and additional device interfaces
Ijdpfxey D Sqvj Amlstf
- Connections for autosamplers and optional modules
- Power supply: 230 V
- Accessories and parts as shown in the images
Technical Data
Manufacturer: Thermo Fisher Scientific
Model: Flash 2000
Device type: Elemental analyzer
Voltage: 230 V AC
Frequency: 50/60 Hz
Fuses: 2 x 6 A
Power consumption: 1400 VA
Autosamplers
Model: AI AS 1310
Supply voltage: 24 V DC
Power: 46 W per unit
Serial numbers: 420126446 and 420126487
Dimensions
Main unit width: approx. 55 to 60 cm
Depth: approx. 55 to 65 cm
Height: approx. 50 to 60 cm
Total width with 2 autosamplers: approx. 100 to 120 cm
Weight
Main unit: approx. 45 to 60 kg
Each autosampler: approx. 8 to 12 kg
Total: approx. 60 to 80 kg
Condition
Used, with age- and usage-related signs of wear. Condition as shown in the images.
Scope of delivery
- Flash 2000 Analyzer
- 2 x Autosamplers
- Accessories and cables as shown
Notes
- The table shown in the photos is not included in the sale
- All information is taken from the nameplate or the device shown
- Subject to errors and prior sale
- We are happy to answer any questions you may have.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
Your listing has been deleted successfully
An error has occurred



































